CODMAN® CERTAS® Plus 828817PLRecalls & reported problems

Integra LifeSciences Switzerland Sàrl · CODMAN® CERTAS® Plus Programmable Valve Inline Small Valve with SIPHONGUARD®, Accessories and Unitised BACTISEAL® Catheter Includes: BACTISEAL Ventricular Catheter, BACTISEAL Unitized Distal Catheter, Priming Adapter, Right Angle Adapter and Information Manual · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10381780535829), received between Aug 4, 2026 and Aug 4, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Disconnection” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Disconnection1
  • Expulsion1
  • Unintended System Motion1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 4, 2026Disconnection; Unintended System Motion; Expulsion

    A facility reported a Certas valve (ID: 828817PL) changed settings:On (b)(6) 2025, it was programmed to 2. On (b)(6) 2026, the patient underwent an X-ray and presented to the emergency room (ER) with a suspected shunt malfunction. A computed tomography (CT) scan performed the same day revealed a shunt disconnection. The right frontal approach ventricular catheter tip had migrated to the suprasellar cistern in the vicinity of the optic chiasm, and the proximal aspect of the ventricular catheter appeared detached from the shunt valve. The ventricular caliber had slightly increased, particularly in the temporal horns, which may reflect developing hydrocephalus. Also on (b)(6) 2026, the patient underwent magnetic resonance imaging (MRI). Following the MRI, the patient was taken to the operating room (OR) to reattach the catheter to the valve. In the operating room, the Medtronic Strata Programming Tool was erroneously used to reset the shunt to 2.0 (a Medtronic setting, not a Certas Plus setting). However, an X-ray taken on (b)(6) 2026, revealed that the Certas valve was set to 4. The patient was exposed to a 1.5T GE magnet.

    Patient problems: Insufficient Information

    MAUDE report 50130372 ↗