NA 1011-40-025Recalls & reported problems
Depuy Orthopaedics, Inc. · SELF TAPPING ROOF PILE SCREW 25mm · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 13
- Deaths reported
- 0
- Injuries reported
- 13
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 10603295000433), received between Dec 1, 2018 and Oct 6, 2021 — classified as 13 injuries.
The most frequently reported specific device problem is “Loss of Osseointegration” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem4
- Loss of Osseointegration3
- Insufficient Device Problem Information2
- Migration2
- Fracture1
- Osseointegration Problem1
- Unintended Movement1
Patient problems
- No Code Available6
- Inadequate Osseointegration3
- Injury3
- Insufficient Information3
- Discomfort2
- Joint Laxity2
- Pain2
- Physical Asymmetry2
Recent adverse event reports
The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.
InjuryOct 6, 2021Migration; Migration
CLINICAL RECORDS, FROM CLINICAL VISITS ON (B)(6) 2021 AND ON (B)(6) 2021, REPORTED THAT THE PATIENT HAD A FAILED TOTAL HIP WITH A PROTRUSIO CAGE PELVIC CONSTRUCT, WITH THE CAGE HAVING FRACTURED PARTIALLY AND MIGRATED INTO THE PELVIC CAVITY. X-RAYS DEMONSTRATED THIS. THE PATIENT WAS EXPERIENCING ONLY MINOR PAIN AND DISCOMFORT, AND SOME SCIATICA, DESPITE THIS, AND WAS AMBULATORY AND CAPABLE OF MODIFIED ACTIVITIES OF DAILY LIVING USING APPLIANCES. THE SURGEON INDICATED THAT THE PROGRESSION OF THE CAGE'S FAILURE MIGHT HAVE REACHED AN ENDPOINT, AS THE PATIENT'S TROCHANTER WAS NOW IMPINGING ON THE PELVIC WING, PREVENTING THE FEMORAL HEAD FROM ENCROACHING INTO THE PELVIS ANY FURTHER. AS A CONSEQUENCE, THE PATIENT'S LEG WAS SHORTENED. A CT SCAN HAD BEEN ORDERED TO BE CERTAIN THAT THE CAGE WAS NOT THREATENING ANY MAJOR PELVIC BLOOD VESSELS. THE PLAN AT PRESENT IS TO HOLD OFF ON DOING ANY SURGICAL INTERVENTION, AS THIS IS CONSIDERED A VERY HIGH RISK SURGERY DUE TO THE APPROACH REQUIRING INVOLVEMENT WITH INTRAPELVIC TISSUES, VESSELS, AND ORGANS.
Patient problems: Discomfort; Insufficient Information; Joint Laxity; Pain; Physical Asymmetry
MAUDE report 12583359 ↗InjuryOct 6, 2021Migration; Migration
CLINICAL RECORDS, FROM CLINICAL VISITS ON (B)(6) 2021 AND ON (B)(6) 2021, REPORTED THAT THE PATIENT HAD A FAILED TOTAL HIP WITH A PROTRUSIO CAGE PELVIC CONSTRUCT, WITH THE CAGE HAVING FRACTURED PARTIALLY AND MIGRATED INTO THE PELVIC CAVITY. X-RAYS DEMONSTRATED THIS. THE PATIENT WAS EXPERIENCING ONLY MINOR PAIN AND DISCOMFORT, AND SOME SCIATICA, DESPITE THIS, AND WAS AMBULATORY AND CAPABLE OF MODIFIED ACTIVITIES OF DAILY LIVING USING APPLIANCES. THE SURGEON INDICATED THAT THE PROGRESSION OF THE CAGE'S FAILURE MIGHT HAVE REACHED AN ENDPOINT, AS THE PATIENT'S TROCHANTER WAS NOW IMPINGING ON THE PELVIC WING, PREVENTING THE FEMORAL HEAD FROM ENCROACHING INTO THE PELVIS ANY FURTHER. AS A CONSEQUENCE, THE PATIENT'S LEG WAS SHORTENED. A CT SCAN HAD BEEN ORDERED TO BE CERTAIN THAT THE CAGE WAS NOT THREATENING ANY MAJOR PELVIC BLOOD VESSELS. THE PLAN AT PRESENT IS TO HOLD OFF ON DOING ANY SURGICAL INTERVENTION, AS THIS IS CONSIDERED A VERY HIGH RISK SURGERY DUE TO THE APPROACH REQUIRING INVOLVEMENT WITH INTRAPELVIC TISSUES, VESSELS, AND ORGANS.
Patient problems: Discomfort; Insufficient Information; Joint Laxity; Pain; Physical Asymmetry
MAUDE report 12583350 ↗InjuryMar 8, 2021Fracture; Fracture
IT WAS REPORTED THAT THE PATIENT BROKE THE PROTRUSIO CAGE AND A FEW SCREWS IMPLANTED BACK IN 2019. SURGEON REMOVED ALL CAGE AND SCREWS ALONG WITH A CEMENTED CUP AND REPLACED WITH A PINNACLE REVISION CUP AND USED DUAL MOBILITY TO HELP PATIENT WITH STABILITY. NO SURGICAL DELAY. DOI:(B)(6) 2019, DOR: (B)(6) 2021, LEFT HIP.
Patient problems: Insufficient Information
MAUDE report 11436238 ↗InjuryFeb 26, 2020Osseointegration Problem; Unintended Movement; Osseointegration Problem; Unintended Movement
PPF AND STICKER SHEETS RECEIVED. THERE WERE NO ALLEGATIONS REPORTED HOWEVER THE PATIENT WAS REVISED AND THE REASON FOR REVISION WAS NOT PROVIDED. DOI: (B)(6) 2017 - DOR: (B)(6) 2018 (LEFT HIP, FIFTH REVISION).
Patient problems: Hemorrhage/Blood Loss/Bleeding; No Code Available
MAUDE report 9753107 ↗InjuryOct 14, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT WAS TAKEN TO OPERATING ROOM FOR REMOVAL OF HARDWARE DUE TO INFECTION AND ONE STAGE REVISION WAS PERFORMED WITH PLACEMENT OF ANTIBIOTIC BEADS. DOI: (B)(6) 2014; DOR: (B)(6) 2019; RIGHT HIP.
Patient problems: No Code Available; Unspecified Infection
MAUDE report 9185890 ↗InjuryJun 10, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
CLINICAL ADVERSE EVENT RECEIVED FOR DVTS BILATERALLY: VASCULAR - DVT EVENT IS SERIOUS AND IS CONSIDERED MODERATE EVENT IS DEFINITELY NOT RELATED TO DEVICE AND POSSIBLY RELATED TO PROCEDURE. DOI: (B)(6) 2019; DOR: (B)(6) 2019 (PELVIC FRACTURE: CUP, LINER, AND HEAD REVISED); DOE: (B)(6) 2019; (RIGHT HIP).
Patient problems: Thrombosis
MAUDE report 8682456 ↗InjuryJun 10, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
CLINICAL ADVERSE EVENT RECEIVED FOR DVTS BILATERALLY: VASCULAR - DVT EVENT IS SERIOUS AND IS CONSIDERED MODERATE EVENT IS DEFINITELY NOT RELATED TO DEVICE AND POSSIBLY RELATED TO PROCEDURE. DOI: (B)(6) 2019; DOR: (B)(6) 2019 (PELVIC FRACTURE: CUP, LINER, AND HEAD REVISED); DOE: (B)(6) 2019; (RIGHT HIP).
Patient problems: Thrombosis
MAUDE report 8682452 ↗InjuryFeb 19, 2019Loss of Osseointegration; Loss of Osseointegration
IT WAS REPORTED THAT HE PROTRUSIO CAGE BROKE AND WAS REMOVED. DUE TO SIGNIFICANT BONE LOSS, ALL COMPONENTS WERE REMOVED AND GIRDLE STONE WAS PERFORMED. IT WAS ALSO REPORTED THAT THERE WAS LOOSENING AT BONE TO IMPLANT INTERFACE BUT IT WAS NOT INDICATED WHICH COMPONENT WAS LOOSE. DOI: (B)(6) 2016; DOR: (B)(6) 2019, RIGHT HIP.
Patient problems: Inadequate Osseointegration; Injury; No Code Available
MAUDE report 8351239 ↗InjuryFeb 19, 2019Loss of Osseointegration; Loss of Osseointegration
IT WAS REPORTED THAT HE PROTRUSIO CAGE BROKE AND WAS REMOVED. DUE TO SIGNIFICANT BONE LOSS, ALL COMPONENTS WERE REMOVED AND GIRDLE STONE WAS PERFORMED. IT WAS ALSO REPORTED THAT THERE WAS LOOSENING AT BONE TO IMPLANT INTERFACE BUT IT WAS NOT INDICATED WHICH COMPONENT WAS LOOSE. DOI: (B)(6) 2016. DOR: (B)(6) 2019; RIGHT HIP.
Patient problems: Inadequate Osseointegration; Injury; No Code Available
MAUDE report 8351232 ↗InjuryFeb 19, 2019Loss of Osseointegration; Loss of Osseointegration
IT WAS REPORTED THAT HE PROTRUSIO CAGE BROKE AND WAS REMOVED. DUE TO SIGNIFICANT BONE LOSS, ALL COMPONENTS WERE REMOVED AND GIRDLE STONE WAS PERFORMED. IT WAS ALSO REPORTED THAT THERE WAS LOOSENING AT BONE TO IMPLANT INTERFACE BUT IT WAS NOT INDICATED WHICH COMPONENT WAS LOOSE. DOI: (B)(6) 2016; DOR: (B)(6) 2019; RIGHT HIP.
Patient problems: Inadequate Osseointegration; Injury; No Code Available
MAUDE report 8351225 ↗InjuryJan 11, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PFS ALLEGES INFECTION, DISLOCATION, MUSCLE DAMAGE AND ANEMIA. AFTER THE REVIEW OF MEDICAL RECORDS FOR MDR REPORTABILITY,PATIENT WAS REVISED TO ADDRESS DISLOCATION,STATUS POST COMPLEX RIGHT REVISION. REVISION NOTES REPORTED OF ANTERIOR DISLOCATION. CLINICAL NOTES REPORTED OF STAPH INFECTION AND PURULENT DRAINAGE.
Patient problems: No Code Available; Unspecified Infection
MAUDE report 8239674 ↗InjuryDec 3, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
PPF AND STICKER SHEETS RECEIVED. PPF ALLEGES PULMONARY EMBOLISM.
Patient problems: Pulmonary Embolism
MAUDE report 8123954 ↗InjuryDec 1, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
PPF AND STICKER SHEETS RECEIVED. PPF ALLEGES PULMONARY EMBOLISM.
Patient problems: Pulmonary Embolism
MAUDE report 8121999 ↗
Other Mesh, surgical, acetabular, hip, prosthesis devices
- NA 1011-40-030Depuy Orthopaedics, Inc. · Mesh, surgical, acetabular, hip, prosthesis13 reports
- NA 1011-40-020Depuy Orthopaedics, Inc. · Mesh, surgical, acetabular, hip, prosthesis11 reports
- NA 1011-40-040Depuy Orthopaedics, Inc. · Mesh, surgical, acetabular, hip, prosthesis11 reports
- NA 1011-40-035Depuy Orthopaedics, Inc. · Mesh, surgical, acetabular, hip, prosthesis9 reports
- NA 1011-40-015Depuy Orthopaedics, Inc. · Mesh, surgical, acetabular, hip, prosthesis8 reports
- NA 1011-71-000Depuy Orthopaedics, Inc. · Mesh, surgical, acetabular, hip, prosthesis4 reports
- NA 1011-02-501Depuy Orthopaedics, Inc. · Mesh, surgical, acetabular, hip, prosthesis3 reports
- Contour 71337156Smith & Nephew, Inc. · Mesh, surgical, acetabular, hip, prosthesis3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page