SIGMA 1024-52-100Recalls & reported problems
Depuy (Ireland) · SIGMA HIGH PERFORMANCE PARTIAL KNEE TIBIAL TRAY UNICONDYLAR METAL BACKED SIZE 1 RM/LL · Class 2 · Implant
All models of SIGMA (380)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 8
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 10603295002376), received between Feb 8, 2018 and Aug 1, 2023 — classified as 8 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem7
- Insufficient Device Problem Information1
Patient problems
- Pain5
- Bone Fracture(s)3
- Fall2
- No Code Available2
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
InjuryAug 1, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT PATIENT UNDERWENT A RIGHT MEDIAL DEPUY HP PARTIAL UNI. INITIALLY PATIENT DID REALLY WELL WITH THIS CONSTRUCT. MORE RECENTLY PATIENT HAS HAD PAIN IN THE KNEE. PATIENT ELECTED TO CONVERT THE UNI TO A TOTAL KNEE. DOI: (B)(6) 2017. DOR: (B)(6) 2023. AFFECTED SIDE: RIGHT KNEE.
Patient problems: Pain
MAUDE report 17434011 ↗InjuryMar 30, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
RIGHT MEDIAL UKA REVISION FOR PAIN AND OSTEOARTHRITIS. DOI: (B)(6) 2020, DOR: (B)(6) 2023, RIGHT KNEE.
Patient problems: Pain
MAUDE report 16643210 ↗InjuryDec 20, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ADDITIONAL INFORMATION RECEIVED INDICATED THAT THERE WAS NO ALLEGE PRODUCT DEFICIENCY. THE PATIENT JUST FELL.
Patient problems: Bone Fracture(s); Fall; Pain
MAUDE report 13043655 ↗InjuryJul 1, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT FELL AND BROKE HER PROXIMAL TIBIA SO DOCTOR TOOK OUT UNI KNEE AND PUT IN TOTAL KNEE DOI: (B)(6) 2021. DOR: (B)(6) 2021; RIGHT KNEE.
Patient problems: Bone Fracture(s); Fall
MAUDE report 12103661 ↗InjuryMar 10, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
InjuryFeb 14, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE SURGEON REPLACE UNI FEMUR, UNI TIBIA, AND UNI INSERT BECAUSE KNEE WAS UNSTABLE. DOI: (B)(6) 2016; DOR: (B)(6) 2020; RIGHT KNEE.
Patient problems: No Code Available
MAUDE report 9711826 ↗InjuryOct 18, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PAINFUL RIGHT KNEE. IMPLANTS REMOVED AND REVISED TO TOTAL.
Patient problems: No Code Available; Pain
MAUDE report 7980605 ↗InjuryFeb 8, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
PATIENT WAS REVISED DUE TO TIBIAL PLATEAU FRACTURE. PATIENT CONSEQUENCE? :NO. IS THE INFORMATION BEING SUBMITTED FOR THIS COMPLAINT ALL THE DETAILS THAT ARE KNOWN/AVAILABLE REGARDING THIS EVENT? : YES.
Patient problems: Bone Fracture(s)
MAUDE report 7251244 ↗
Other PROSTHESIS, KNEE PATELLOFEMOROTIBIAL, PARTIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- INSTRUMENT I-K3834CG2LHowmedica Osteonics Corp. · PROSTHESIS, KNEE PATELLOFEMOROTIBIAL, PARTIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER1 recall0 reports
- INSTRUMENT I-K3834CG3RHowmedica Osteonics Corp. · PROSTHESIS, KNEE PATELLOFEMOROTIBIAL, PARTIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER1 recall0 reports
- RESTORIS 170616Mako Surgical Corp. · PROSTHESIS, KNEE PATELLOFEMOROTIBIAL, PARTIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER1 recall0 reports
- INSTRUMENT I-K3834CG2RHowmedica Osteonics Corp. · PROSTHESIS, KNEE PATELLOFEMOROTIBIAL, PARTIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER1 recall0 reports
- INSTRUMENT I-K3834CG3LHowmedica Osteonics Corp. · PROSTHESIS, KNEE PATELLOFEMOROTIBIAL, PARTIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER1 recall0 reports
- SIGMA 1024-51-300Depuy (Ireland) · PROSTHESIS, KNEE PATELLOFEMOROTIBIAL, PARTIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER16 reports
- SIGMA 1024-54-307Depuy (Ireland) · PROSTHESIS, KNEE PATELLOFEMOROTIBIAL, PARTIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER12 reports
- SIGMA 1024-07-400Depuy (Ireland) · PROSTHESIS, KNEE PATELLOFEMOROTIBIAL, PARTIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER11 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page