Skip to content

PINNACLE 1219-36-066Recalls & reported problems

Depuy Orthopaedics, Inc. · PINNACLE HIP SOLUTIONS MARATHON POLYETHYLENE ACETABULAR LINER NEUTRAL 36mm ID 66mm OD · Class 2 · Implant

All models of PINNACLE (182)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10603295014515), received between Jul 10, 2024 and Sep 6, 2024 — classified as 2 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Device Dislodged or Dislocated1

Patient problems

  • Joint Laxity2
  • Joint Dislocation1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjurySep 6, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT WAS REVISED WITH HEAD AND LINER DUE TO INSTABILITY. DOI: UNKNOWN. DOR: (B)(6) 2024. AFFECTED SIDE: LEFT HIP.

    Patient problems: Joint Laxity

    MAUDE report 20158782 ↗
  • InjuryJul 10, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THIS IS A LIMITED REVIEW OF MEDICAL RECORDS THAT PERTAINS TO A NON MOM CONSTRUCT AFTER 1ST REVISION WAS DONE. ON (B)(6) 2015, THE PATIENT HAD A REVISION RIGHT HIP STICKER PAGE 13 OF 20 A DEPUY PINNACLE MARATHON POLY LINER WAS INSERTED ALONG WITH COMPETITOR STEM/FEMORAL HEAD. (B)(4). ON (B)(6) 2015 THE PATIENT HAD A CLOSED REDUCTION OF RIGHT TOTAL HIP TO ADDRESS DISLOCATED RIGHT HIP. (ADD TO NEXT PC). ON (B)(6) 2015 THE PATIENT HAD A REVISION RIGHT HIP ARTHROPLASTY TO ADDRESS RECURRENT INSTABILITY. THE HEAD AND LINER WERE REVISED, AND CONVERTED TO A ¿CAPTURED¿ LINER (LOCKING). PATIENT RETAINED THEIR DEPUY CUP AND COMPETITOR STEM. DOI: (B)(6) 2015. DOR: (B)(6) 2015. RIGHT HIP SECOND REVISION.

    Patient problems: Joint Dislocation; Joint Laxity

    MAUDE report 19711288 ↗

Other PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED devices

All PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page