S-ROM 1365-65-500Recalls & reported problems

Depuy (Ireland) · S-ROM M-Spec FEMORAL HEAD Diameter 44mm +9 Offset 11/13 TAPER · Class 2 · Implant

All models of S-ROM (185)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10603295034216), received between Sep 12, 2018 and Apr 5, 2024 — classified as 2 injuries.

The most frequently reported specific device problem is “Degraded” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Degraded1

Patient problems

  • Foreign Body Reaction1
  • Hypersensitivity/Allergic reaction1
  • Inflammation1
  • Osteolysis1
  • Pain1
  • Swelling/ Edema1
  • Tissue Damage1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 5, 2024Degraded; Degraded

    MEDICAL RECORDS RECEIVED. DOI: (B)(6) 2007: MALE PATIENT WITH A HISTORY OF LEFT HIP FEMORAL FRACTURE, LEFT HIP COMPETITOR ORIF, LEFT HIP COMPETITOR THA, ACETABULAR AND FEMORAL OSTEOLYSIS, AND CHRONIC SEPSIS INFECTION RECEIVED A DEPUY MOM REVISION THA AS STAGE 2 TREATMENT OF INFECTION. THE ACETABULAR CUP WAS SECURED WITH A DOME SCREW AND THE ACETABULAR OSTEOLYSIS REQUIRED BONE GRAFTING. THE PREVIOUS FEMORAL FRACTURE SITE WAS PARTIALLY HEALED AND REQUIRED A LARGER BONE CUT AND THE USE OF AN S-ROM STEM AND SLEEVE. THE SURGEONS NOTED THERE WAS SOME SHORTENING OF THE LEFT LEG BECAUSE OF THE PREEXISTING FRACTURE CAUSED BY AN MVA. THE PROCEDURE WAS COMPLETED WITHOUT COMPLICATIONS. CT SCAN AND PREOPERATIVE TESTING (B)(6) 2024: A MALE PATIENT IS REFERRED FOR REVISION SURGERY AFTER FAILED ATTEMPTS AT TREATING CHRONIC LEFT HIP PAIN. PREOPERATIVE ASPIRATION DOES NOT DETECT ELEVATED SERUM OR SYNOVIAL HEAVY METAL IONS BUT DOES DETECT ELEVATED INFLAMMATORY MARKERS. CT SCANS IDENTIFY A LARGE PSEUDOTUMOR AS WELL AS EXTENSIVE ACETABULAR AND FEMORAL OSTEOLYSIS. THESE WERE PREEXISTING EVENTS AND ARE PART OF THE TREATMENT OF REVISION CAPTURED ON (B)(4).

    Patient problems: Foreign Body Reaction; Hypersensitivity/Allergic reaction; Inflammation; Osteolysis; Pain; Swelling/ Edema

    MAUDE report 19051419 ↗
  • InjurySep 12, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PPF AND STICKER SHEETS RECEIVED. PPF ALLEGES ABDUCTOR MUSCLE REPAIR AND LOOSENING OF CUP. IT WAS FOUND OUT IN THE STICKER SHEETS THAT THE DEPUY PRODUCTS INVOLVED ARE THE STEM AND HEAD, THE REST ARE NON DEPUY. IT WAS ALSO INDICATED THAT THE CUP, LINER, HEAD AND STEM WERE REMOVED. DOI: (B)(6) 2009 - DOR: (B)(6) 2010 (RIGHT HIP).

    Patient problems: Tissue Damage

    MAUDE report 7868069 ↗

Other Prosthesis, hip, semi-constrained, metal/polymer, cemented devices

All Prosthesis, hip, semi-constrained, metal/polymer, cemented devices →