ATTUNE 1506-10-005Recalls & reported problems
Depuy (Ireland) · ATTUNE KNEE SYSTEM TIBIAL BASE ROTATING PLATFORM SIZE 5 CEMENTED · Class 3 · Implant
All models of ATTUNE (1475)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
Quick summary
This DePuy Attune knee implant is the lower part of a cemented knee replacement system. The 440 reports mostly describe the implant loosening or failing to bond with the cement, often leading to repeat surgery, and many describe pain. There are 439 injuries, 1 malfunction and no deaths, and no recalls name this device. Reports dropped from 8 in the year before to 2 in the most recent year.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 442
- Deaths reported
- 0
- Injuries reported
- 441
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 442 adverse event reports that list this exact device (DI 10603295042594), received between Jul 5, 2017 and Sep 28, 2026 — classified as 441 injuries, 1 malfunction.
The most frequently reported specific device problem is “Loss of or Failure to Bond” (344 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Loss of or Failure to Bond344
- Adverse Event Without Identified Device or Use Problem57
- Migration43
- Loose or Intermittent Connection18
- Insufficient Device Problem Information14
- Loosening of Implant Not Related to Bone-Ingrowth12
- Unintended Movement12
- Migration or Expulsion of Device9
Patient problems
- No Code Available269
- Pain245
- Adhesion(s)48
- Insufficient Information32
- Not Applicable32
- Edema20
- Limited Mobility Of The Implanted Joint17
- Unspecified Infection17
Recent adverse event reports
The 25 most recent of 442 reports, in the reporter's own words as published by the FDA.
InjurySep 28, 2026Loss of or Failure to Bond
Patient problems: Joint Laxity
MAUDE report 50921575 ↗InjuryAug 3, 2026Loss of or Failure to Bond
It was reported that there was a Revision of an Attune PSRP construct which was implanted on the patient's right side. Reason for revision was due to tibial loosening. There was no surgical delay.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 50113796 ↗InjuryDec 30, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
SUBJECT ID: (B)(6), STUDY NO: (B)(6). CLINICAL ADVERSE EVENT RECEIVED FOR RIGHT KNEE ARTHROPLASTY INFLAMMATORY REACTION TO METAL DEVICE AND PROCEDURE (RELATEDNESS). DEVICE RELATED: POSSIBLY RELATED. PROCEDURE RELATED: POSSIBLY RELATED. DATE OF EVENT: 13 DEC 2018. DATE OF IMPLANT: (B)(6) 2014. DATE OF REVISION: NO INFORMATION PROVIDED. DEVICE LOCATION: RIGHT. TREATMENT/IMPACT: RESULTED IN A MEDICAL OR SURGICAL INTERVENTION, SURGICAL TREATMENT OF STUDY KNEE (DATE: (B)(6) 2019), COMPONENTS REMOVED (FEMORAL COMPONENT; TIBIAL BASE).
Patient problems: Hypersensitivity/Allergic reaction; Inflammation
MAUDE report 23929019 ↗InjuryNov 4, 2025Loss of or Failure to Bond; Loss of or Failure to Bond
(B)(6) FIRST REPORT OF RETRIEVALS FOR STATEMENT OF WORK 10 FOR Q3 OF 2025. (B)(6) IS THE RESEARCH LOCATION, AND NOT THE FACILITY OF PLACEMENT. A DEPUY SYNTHES IMPLANT WAS REVISED AND REVIEWED FOR ANALYSIS. REASON FOR REVISION: REVISION DUE TO LOOSE TIBIAL TRAY, POLY WEAR, AND PAIN. THE NON-ARTICULAR SURFACE OF THE CEMENTED TIBIAL TRAY SHOWS NO CEMENT REMAINING. CEMENT MFG IS UNKNOWN.
Patient problems: Pain
MAUDE report 23468627 ↗InjuryApr 21, 2025Loss of or Failure to Bond; Loss of or Failure to Bond
IT WAS REPORTED THAT THE PATIENT WAS REVISED FOR IMPLANT LOOSENING DUE TO BREAKDOWN OF BONDING BETWEEN CEMENT AND TRAY INTERFACE. THERE WAS NO DELAY IN SURGERY. AFFECTED SIDE: UNKNOWN KNEE.
Patient problems: Insufficient Information
MAUDE report 21872620 ↗InjuryApr 3, 2025Migration; Migration
IT WAS REPORTED THAT THE PATIENT'S TIBIAL BONE HAD COLLAPSED. SURGEON DECIDED TO REVISE ALL COMPONENTS WITH SLEEVES AND STEMS. NOTHING WAS SAID ABOUT PROBLEMS WITH THE COMPONENTS JUST THAT THE TIBIAL BONE WAS VERY SOFT. TIME WAS NOT EXTENDED DUE TO ANY OF THE PRODUCTS. AFFECTED SIDE: RIGHT KNEE.
Patient problems: Unspecified Tissue Injury
MAUDE report 21762497 ↗InjuryMar 20, 2025Loss of or Failure to Bond; Loss of or Failure to Bond
PATIENT WAS REVISED DUE TO LOOSENING OF THE TIBIA AND FEMUR AT THE CEMENT TO IMPLANT INTERFACE. CEMENT MANUFACTURER WAS UNKNOWN. DOI: UNKNOWN. DOR: (B)(6) 2025. AFFECTED SIDE: RIGHT KNEE.
Patient problems: Insufficient Information
MAUDE report 21655093 ↗InjuryJan 28, 2025Loss of or Failure to Bond; Loss of or Failure to Bond
IT WAS REPORTED THAT THE PATIENT WAS REVISED DUE TO LOOSENING OF THE TIBIA AT UNKNOWN INTERFACE. SURGEON REVISED THE TIBIA TO AN RP CRS WITH CEMENTED STEMS AND A 10MM RM WEDGE. THE FEMUR WAS WELL FIXED, SO HE LEFT THAT AND USED AN RPPS POLY. NO FURTHER PATIENT INFORMATION IS AVAILABLE AT THIS TIME. CEMENT MANUFACTURER WAS UNKNOWN. AFFECTED SIDE: LEFT KNEE.
Patient problems: Insufficient Information
MAUDE report 21252317 ↗InjuryJan 24, 2025Loss of or Failure to Bond; Noise, Audible; Loss of or Failure to Bond; Noise, Audible
ON (B)(6)2018, THE PATIENT UNDERWENT A PRIMARY RIGHT KNEE REPLACEMENT USING ATTUNE IMPLANTS INCLUDING A PATELLA AND SMARTSET BONE CEMENT. ON (B)(6)-2018, SHE EXPERIENCED A NEW ONSET OF RIGHT KNEE PAIN AFTER DOING SOME HOUSE CLEANING. SHE STATES THERE IS A LOT OF CLICKING AND STIFFNESS AS WELL. PHYSICAL THERAPY IS ORDERED. ON (B)(6)2024, THE PATIENT HAS A RIGHT KNEE BONE SCAN REVEALING SUSPECTED LOOSENING OF THE FEMORAL AND TIBIAL COMPONENTS. ON (B)(6)2024, THE PATIENT UNDERWENT A RIGHT KNEE REVISION. INTRAOPERATIVELY THERE WAS SCAR TISSUE, EXTENSIVE SYNOVITIS, AND THE TIBIAL COMPONENT WAS CONFIRMED TO BE LOOSE AT THE IMPLANT TO CEMENT INTERFACE. THE FEMORAL COMPONENT WAS WELL FIXED. THE PATIENT WAS REVISED TO COMPETITOR IMPLANTS THOUGH THE PATELLA WAS LEFT IN SITU. DOI: (B)(6), 2018. DOR: (B)(6) 2024. RIGHT KNEE.
Patient problems: Adhesion(s); Muscular Rigidity; Pain; Synovitis
MAUDE report 21228500 ↗InjuryJan 22, 2025Loss of or Failure to Bond; Loss of or Failure to Bond
IT WAS REPORTED THAT THE PATIENT WAS REVISED DUE TO ASEPTIC LOOSENING. ALL IMPLANTS WERE LOOSE AT THE CEMENT/IMPLANT INTERFACE AND DEPUY CEMENT WAS USED. AFFECTED SIDE: RIGHT KNEE.
Patient problems: Insufficient Information
MAUDE report 21211275 ↗InjuryNov 13, 2024Loss of or Failure to Bond; Loss of or Failure to Bond
IT WAS REPORTED THAT ON (B)(6) 2016, THE PATIENT UNDERWENT A LEFT TKA DUE TO ARTHRITIS. THE PATELLA WAS RESURFACED AND DEPUY CEMENT X2 WAS USED. THERE WERE NO COMPLICATIONS NOTED. ON (B)(6) 2021, THE PATIENT UNDERWENT A REVISION OF THE LEFT TKA DUE TO FAILED KNEE. THE TIBIAL COMPONENT WAS NOTED TO LOOSEN AND WAS REMOVED FROM THE CEMENT VERY EASILY. THE FEMORAL COMPONENT, PATELLA, AND INSERT WERE ALSO REVISED, BUT THERE WERE NO ALLEGATIONS REPORTED AGAINST THOSE PRODUCTS. COMPETITOR IMPLANTS AND CEMENT WERE PLACED AT REVISION. DOI: (B)(6) 2016; DOR: (B)(6) 2021; LEFT.
Patient problems: Insufficient Information
MAUDE report 20672727 ↗InjuryNov 12, 2024Loss of or Failure to Bond; Loss of or Failure to Bond
ON (B)(6) 2018, PATIENT REPORTEDLY RECEIVED A LEFT TOTAL KNEE REVISION TO ADDRESS PAIN, FLEXION INSTABILITY, AND ASEPTIC LOOSENING OF THE TIBIAL BASEPLATE. SURGEON IDENTIFIED THAT ALTHOUGH THE FEMUR WAS WELL-FIXED, THE FLEXION INSTABILITY REQUIRED REVISION OF THE FEMUR AND TIBIA. THE TIBIAL TRAY WAS LOOSE--INTERFACE UNSPECIFIED. THE PATELLA WAS FOUND TO BE WELL-FIXED AND WAS RETAINED. FEMUR WAS REPLACED WITH DEPUY ATTUNE REVISION FEMUR SIZE 6, A 30MM SLEEVE, AND 4MM DISTAL AND POSTERIOR AUGMENTS, AND A 14 X 60 FEMORAL STEM. THE TIBIAL TRAY WAS REPLACED WITH AN ATTUNE REVISION TIBIAL TRAY SIZE 6, A 37MM SLEEVE, AND 14 X 60 TIBIAL STEM. THERE WERE NO COMPLICATIONS. DOI: (B)(6) 2015. DOR: (B)(6) 2018. LEFT KNEE.
Patient problems: Joint Laxity; Pain
MAUDE report 20663660 ↗InjuryOct 25, 2024Loss of or Failure to Bond; Loss of or Failure to Bond
IT WAS REPORTED THAT THERE WAS OSTEOLYTIC CHANGES IN THE PATELLA AND INCREASING PAIN & SWELLING IN PATIENT'S KNEE. TOTAL KNEE REVISION WAS PERFORMED. IT IS UNKNOWN IF THE PATIENT HAD A FALL OR OTHER TRAUMATIC EVENT. ADDITIONALLY, IT WAS REPORTED THAT THERE WAS TIBIAL LOOSENING AT THE CEMENT/IMPLANT INTERFACE. CEMENT MANUFACTURER WAS UNKNOWN. THERE WERE NO BROKEN IMPLANTS OR INSTRUMENTS. NO ADVERSE OCCURRENCES TO THE PATIENT. NO SURGICAL DELAY. LOT NUMBERS WERE READ FROM THE SURGICAL FIELD, NO OTHER RECORD IS AVAILABLE. DOI: (B)(6) 2015. DOR: (B)(6) 2024. AFFECTED SIDE: LEFT KNEE.
Patient problems: Osteolysis; Pain; Swelling/ Edema
MAUDE report 20533691 ↗MalfunctionJun 13, 2024Loss of or Failure to Bond; Loss of or Failure to Bond
STUDY: DPO 10004 10008 ATTUNE. SUBJECT ID: (B)(6). ADVERSE EVENT: (DIAGNOSIS) SUSPECT LOOSENING TIBIAL COMPONENT (NO RADIOLUCENCIES). DATE OF IMPLANTATION: (B)(6) 2013. DATE OF ONSET: 03 DEC 2015. DATE OF REVISION: NONE. SEVERITY: MODERATE. RELATION TO STUDY DEVICE? DEFINITELY RELATED. RELATION TO STUDY PROCEDURE? POSSIBLY RELATED. TREATMENT: OBSERVATION (NO REVISION AT THIS TIME).
Patient problems: Insufficient Information
MAUDE report 19532097 ↗InjuryJun 10, 2024Loss of or Failure to Bond; Loss of or Failure to Bond
STUDY: (B)(6). SUBJECT ID: (B)(6). ADVERSE EVENT: (DIAGNOSIS) LOOSE TIBIAL COMPONENT. NO CEMENT ADHERENCE TO IMPLANT DATE OF IMPLANTATION: (B)(6) 2014 DATE OF ONSET: ON (B)(6) 2016 DATE OF REVISION: ON (B)(6) 2016 SEVERITY: SEVERE RELATION TO STUDY DEVICE? DEFINITELY RELATED RELATION TO STUDY PROCEDURE? POSSIBLY RELATED TREATMENT: FEMORAL & TIBIA TRAY/INSERT REVISION; PATELLA RETAINED.
Patient problems: Insufficient Information
MAUDE report 19497753 ↗InjuryApr 2, 2024Use of Device Problem; Use of Device Problem
IT WAS REPORTED THAT THE PATIENT WAS REVISED DUE TO MISALIGNED TIBIA, UNSTABLE KNEE. DOI: (B)(6) 2015. DOR: (B)(6) 2024. AFFECTED SIDE : RIGHT KNEE.
Patient problems: Joint Laxity
MAUDE report 19020033 ↗InjuryMar 23, 2024Loss of or Failure to Bond; Loss of or Failure to Bond
ADDITIONAL INFORMATION RECEIVED: A. CAN YOU CONFIRM THE PRIMARY SURGERY DATE OR THE ORIGINAL IMPLANTATION DATE? B. IT WAS INDICATED THAT THERE WAS LOOSENING. ON WHAT INTERFACE DID THE LOOSENING OCCUR? C. PLEASE CONFIRM THE MANUFACTURER OF THE CEMENT PRODUCT. IS IT DEPUY MANUFACTURED? ALSO FOR THE QUANTITY USED. D. WAS THERE ANY ALLEGATION AGAINST THE INSERT? RESPONSE/ANSWER: I DO NOT KNOW THE ORIGINAL IMPLANTATION DATE, HOWEVER, IT WAS COMPLETED AROUND 2021. LOOSENING OCCURRED ON THE TIBIA BONE TO TIBIAL BASEPLATE LOOSENING. NO CEMENT WAS STUCK TO THE BOTTOM OF THE IMPLANT. ALL CEMENT WAS STUCK TO THE TIBIA. I DO NOT KNOW WHAT CEMENT THE SURGEON TYPICALLY USED. THERE WAS NO ALLEGATION AGAINST THE INSERT.
Patient problems: Insufficient Information
MAUDE report 18966089 ↗InjuryMar 4, 2024Loss of or Failure to Bond; Migration; Loss of or Failure to Bond; Migration
THE PATIENT UNDERWENT A RIGHT PRIMARY KNEE REPLACEMENT ON (B)(6) 2016 UTILIZING ATTUNE IMPLANTS WITH NO INDICATION OF CEMENT MANUFACTURER. ON (B)(6) 2023, THE PATIENT BEGAN TO HAVE PAIN AND WAS LIMPING. XRAY REVIEW IDENTIFIED GROSS LOOSENING AND EARLY COLLAPSE OF THE RIGHT TIBIA. ON (B)(6) 2023, THE PATIENT WAS REVISED AND THE TRAY WAS CONFIRMED TO BE LOOSE AT THE IMPLANT TO CEMENT INTERFACE. DOI: (B)(6) 2016. DOR: (B)(6) 2023 (RIGHT KNEE).
Patient problems: Adhesion(s); Ambulation or Postural Difficulties; Pain; Unspecified Musculoskeletal problem
MAUDE report 18825094 ↗InjuryJan 29, 2024Migration; Migration
IT WAS REPORTED THAT PATIENT WAS REVISED DUE TO PROXIMAL TIBIA COLLAPSE. REVISION SURGERY WENT WELL, ATTUNE 12 X 110 PRESS FIT STEM, 45 SLEEVE, AND A REVISION TIBIA WAS UTILIZED. PATIENT STATUS/ OUTCOME / CONSEQUENCES -YES, PATIENT CONSEQUENCE DESCRIPTION/WAS THERE A CLINICAL OUTCOME EXPERIENCED BY THE PATIENT (INFECTION, INFLAMMATION, ETC.)? TKA HAD TO BE REVISED, WAS OTHER MEDICAL INTERVENTION (E.G. X-RAYS, ADDITIONAL PROCEDURES, PRESCRIPTIONS, OTC, REVISION) REQUIRED: YES, IF YES, DESCRIBE: TKA HAD TO BE REVISED. IS THE PATIENT PART OF A CLINICAL STUDY: UNKNOWN. (B)(4), DEVICE PROPERTY OF: NONE, DEVICE IN POSSESSION OF: NONE. (B)(4), DEVICE PROPERTY OF: NONE, DEVICE IN POSSESSION OF: NONE. BY CHECKING THIS BOX I CERTIFY THAT ALL INFORMATION THAT ARE KNOWN/AVAILABLE HAS BEEN DISCLOSED. IF ANY NEW INFORMATION WILL BE MADE AVAILABLE, THE ADDITIONAL INFORMATION WILL BE SUBMITTED THROUGH CST.- TRUE.
Patient problems: Insufficient Information
MAUDE report 18598761 ↗InjuryJan 4, 2024Loss of or Failure to Bond; Loss of or Failure to Bond
(B)(6). CLINICAL NOTIFICATION RECEIVED FOR REVISION ASEPTIC LOOSENING. DATE OF IMPLANT: (B)(6) 2017. DATE OF REVISION: (B)(6) 2023 (LEFT KNEE). TREATMENT: FEMORAL COMPONENT, TIBIAL BASE, AND INSERT WERE REVISED.
Patient problems: Insufficient Information
MAUDE report 18443354 ↗InjuryDec 28, 2023Loss of or Failure to Bond; Loss of or Failure to Bond
PATIENT'S TIBIA WAS REVISED DUE TO PAIN AND BONE SHOWING UP HOT ON BONE SCAN. SURGEON DID NOT FEEL THAT THE TIBIAL TRAY WAS GROSSLY LOOSE AND DID REQUIRE SOME WORK TO REMOVE. NO CEMENT WAS BONDED TO THE BOTTOM OF THE TRAY. THE SURGEON DID NOTE THAT THE TISSUE AT THE BONE-CEMENT INTERFACE WAS GRAY IN COLOR AND HE FELT THE DISCOLORATION WAS THE RESULT OF MICROMOTION. THERE WAS NO DELAY IN SURGERY. DOI: (B)(6) 2015. DOR: (B)(6) 2023. AFFECTED SIDE: LEFT KNEE.
Patient problems: Pain
MAUDE report 18409097 ↗InjuryOct 11, 2023Loss of or Failure to Bond; Loss of or Failure to Bond
PATIENT UNDERWENT AN ATTUNE RPPS CONSTRUCT UTILIZING THE PRE S+ ATTUNE TIBIA WITH NO UNDERSIDE POCKETS. RECENTLY SHE WAS EXPERIENCING PAIN IN HER KNEE. UPON OPENING HER KNEE IT WAS DISCOVERED THAT HER TIBIAL WAS LOOSE. THE FEMUR AND INSERT WERE REMOVED AS WELL. THE PATELLA COMPONENT WAS RETAINED AND A FULL ATTUNE CRS REVISION CONSTRUCT WAS PLACED. SHE IS NOT CONFIRMED FOR INFECTION. DOI: (B)(6) 2015, DOR: (B)(6) 2023, AFFECTED SIDE: RIGHT KNEE.
Patient problems: Pain
MAUDE report 17916525 ↗InjuryOct 11, 2023Loss of or Failure to Bond; Loss of or Failure to Bond
PATIENT UNDERWENT AN ATTUNE RPPS CONSTRUCT UTILIZING THE PRE S+ ATTUNE TIBIA WITH NO UNDERSIDE POCKETS. RECENTLY SHE WAS EXPERIENCING PAIN IN HER KNEE. UPON OPENING HER KNEE IT WAS DISCOVERED THAT HER TIBIAL WAS LOOSE. THE FEMUR AND INSERT WERE REMOVED AS WELL. THE PATELLA COMPONENT WAS RETAINED AND A FULL ATTUNE CRS REVISION CONSTRUCT WAS PLACED. SHE IS NOT CONFIRMED FOR INFECTION. DOI: (B)(6) 2015, DOR: (B)(6) 2023, AFFECTED SIDE: RIGHT KNEE.
Patient problems: Pain
MAUDE report 17916413 ↗InjurySep 26, 2023Loss of or Failure to Bond; Loss of or Failure to Bond
PATIENT WAS REVISED DUE TO PAIN AND LOOSENING OF TIBIA AT UNKNOWN INTERFACE. DOI: UNKNOWN . DOR: (B)(6) 2023. AFFECTED SIDE: RIGHT KNEE.
Patient problems: Pain
MAUDE report 17816168 ↗InjurySep 6, 2023Loss of or Failure to Bond; Loss of or Failure to Bond
PATIENT WAS REVISED DUE TO ASEPTIC LOOSENING OF THE TIBIAL COMPONENT AT THE CEMENT/IMPLANT INTERFACE. DEPUY CEMENT WAS USED. DOI: (B)(6) 2016. DOR: (B)(6) 2023. AFFECTED SIDE: RIGHT KNEE.
Patient problems: Insufficient Information
MAUDE report 17689844 ↗
Other Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing devices
- ATTUNE 1506-10-004Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing442 reports
- ATTUNE 1518-20-038Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing3 deaths393 reports
- LCS SIGMA 1294-33-130Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing1 recall310 reports
- ATTUNE 1518-20-035Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing342 reports
- P.F.C. SIGMA 96-0102Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing1 death319 reports
- ATTUNE 1518-20-041Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing308 reports
- ATTUNE 1506-10-007Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing284 reports
- P.F.C. SIGMA 96-0103Depuy (Ireland) · Prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing257 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page