SUMMIT 1570-02-080Recalls & reported problems

Depuy Orthopaedics, Inc. · SUMMIT FEMORAL STEM 12/14 TAPER TAPERED w/DUOFIX HA SIZE 2 STD 130mm · Class 2 · Implant

All models of SUMMIT (53)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10603295059431), received between Feb 13, 2018 and Sep 22, 2021 — classified as 5 injuries.

The most frequently reported specific device problem is “Corroded” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Corroded2
  • Biocompatibility1
  • Degraded1
  • Insufficient Device Problem Information1
  • Naturally Worn1
  • Osseointegration Problem1

Patient problems

  • No Code Available2
  • Test Result2
  • Tissue Damage2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Fall1
  • Hypersensitivity/Allergic reaction1
  • Inadequate Osseointegration1
  • Injury1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjurySep 22, 2021Osseointegration Problem; Osseointegration Problem

    IT WAS REPORTED THAT THE PT. FELL AND FRACTURED THE PROXIMAL FEMUR. IT WAS ALSO INDICATED THAT THERE WAS LOOSENING OF THE STEM AND CUP AT THE BONE TO IMPLANT INTERFACE. THE STEM WAS LOOSE BUT DURING THE CASE, THEY DISCOVERED THAT THE CUP WAS ALSO LOOSE. HE REVISED BOTH GOING TO A 48 CUP AND CORAIL REVISION STEM. EVERYTHING WAS STABLE FOLLOWING THE REVISION. DOI: (B)(6) 2021. DOR: (B)(6) 2021, AFFECTED SIDE: LEFT HIP.

    Patient problems: Fall; Inadequate Osseointegration; Limb Fracture

    MAUDE report 12512907 ↗
  • InjuryMar 4, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT ADMITTED TO HOSPITAL WITH SUSPECTED C-DIFF, STOPPED TAKING ANTIBIOTICS, HIP UNSTABLE, HIP PROSTHESIS SUSPECTED TO BE INFECTED. ONCE EXPOSURE GAINED FRANK PUS EMERGED AND DECISION WAS MADE TO REMOVE ALL FEMORAL COMPONENTS.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Joint Laxity

    MAUDE report 11416375 ↗
  • InjuryMar 13, 2020Corroded; Degraded; Corroded; Degraded

    UNF AND MEDICAL RECORDS RECEIVED. AFTER REVIEW OF MEDICAL RECORDS, PATIENT WAS REVISED TO ADDRESS FAILED RIGHT TOTAL HIP REPLACEMENT SECONDARY TO METAL-METAL DISEASE. PATIENT HAS ELEVATED METAL IONS AND A SMALL PSEUDOTUMOR. OPERATIVE NOTES STATED THAT A STANDARD ANTEROLATERAL APPROACH WAS MADE THROUGH THE PREVIOUS INCISION. THERE WAS NOTED TO BE SOME ABDUCTOR DISEASE BUT MOSTLY THE ABDUCTOR WAS INTACT. THE PSEUDOCAPSULE WAS EXCISED AND THIS WAS PSEUDOTUMOROUS. THERE WAS A SIGNIFICANT CORROSION NOTED WHEN THE HEAD WAS REMOVED FROM THE NECK. DOI: (B)(6) 2005. DOR: (B)(6) 2017. (RIGHT HIP). THE PATIENT HAS BILATERAL HIP IMPLANTS. PLEASE SEE (B)(4) FOR THE LEFT HIP.

    Patient problems: Hypersensitivity/Allergic reaction; No Code Available; Test Result; Tissue Damage

    MAUDE report 9832068 ↗
  • InjuryApr 10, 2019Biocompatibility; Adverse Event Without Identified Device or Use Problem; Biocompatibility; Adverse Event Without Identified Device or Use Problem

    PPF ALLEGES METAL WEAR AND ELEVATED METAL IONS.

    Patient problems: No Code Available; Test Result; Tissue Damage

    MAUDE report 8500428 ↗
  • InjuryFeb 13, 2018Corroded; Naturally Worn; Insufficient Device Problem Information; Corroded; Naturally Worn; Insufficient Device Problem Information

    COMPLAINT DESCRIPTION: PATIENT WAS REVISED TO ADDRESS ELEVATED ION LEVELS.

    Patient problems: Injury; Limited Mobility Of The Implanted Joint; Pain

    MAUDE report 7266071 ↗

Other Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate devices

All Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate devices →