Skip to content

P.F.C. SIGMA 1581-25-108Recalls & reported problems

Depuy (Ireland) · P.F.C. SIGMA TIBIAL INSERT FIXED BEARING STABILIZED 5 8mm XLK · Class 2 · Implant

All models of P.F.C. SIGMA (487)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
13
Deaths reported
0
Injuries reported
11
Recalls naming it
0

Summary

The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 10603295064657), received between May 17, 2018 and Aug 12, 2026 — classified as 11 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Defective Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 1 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem10
  • Defective Device1
  • Device Damaged Prior to Use1
  • Difficult to Insert1
  • Noise, Audible1

Patient problems

  • Unspecified Infection6
  • No Code Available4
  • Insufficient Information3
  • Pain3
  • Joint Laxity1
  • Not Applicable1
  • Osteolysis1

Recent adverse event reports

The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 12, 2026Adverse Event Without Identified Device or Use Problem

    Patient problems: Unspecified Infection

    MAUDE report 50226536 ↗
  • InjuryJun 6, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT WAS REVISED DUE TO INSTABILITY. SURGEON DID DEBRIDEMENT AND EXCHANGED INSERT TO 10MM. THERE WAS NO ADVERSE CONSEQUENCE AND NO SURGICAL DELAY. AFFECTED SIDE: LEFT KNEE.

    Patient problems: Joint Laxity

    MAUDE report 22157737 ↗
  • InjuryMay 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PATIENT COMPLAINED OF KNEE PAIN. UPON REVIEW ON X-RAY, TIBIAL COMPONENT LOOKED LOOSE AND SLIGHTLY COLLAPSED INTO VARUS. THERE WAS SIGNIFICANT WEAR AROUND THE FEMUR AS WELL. IT IS UNKNOWN IF THERE WAS A SURGICAL DELAY. PROCEDURE AND PATIENT OUTCOME ARE UNKNOWN. DOI: (B)(6) 2011, DOR: (B)(6) 2025, AFFECTED AREA: RIGHT KNEE.

    Patient problems: Osteolysis; Pain

    MAUDE report 21988213 ↗
  • InjuryApr 22, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT UNDERWENT SURGERY TO SWAP POLY FOR AN UNKNOWN REASON. AFFECTED SIDE: LEFT KNEE.

    Patient problems: Insufficient Information

    MAUDE report 21884778 ↗
  • InjuryNov 9, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION WAS RECEIVED AND STATED THAT NO DELAYS IN SURGERY OCCURRED OR ANY PATIENT HARMS WERE REPORTED. THE EVENT OCCURRED DURING PRIMARY SURGERY.

    Patient problems: Unspecified Infection

    MAUDE report 18101243 ↗
  • InjuryAug 8, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT WAS REVISED DUE TO INFECTION. WASHOUT AND POLY EXCHANGE PERFORMED. DOI: UNKNOWN, DOR: (B)(6), 2023, AFFECTED SIDE: LEFT KNEE.

    Patient problems: Unspecified Infection

    MAUDE report 17479435 ↗
  • MalfunctionJul 21, 2023Device Damaged Prior to Use; Defective Device; Device Damaged Prior to Use; Defective Device

    ADDITIONAL INFORMATION WAS RECEIVED AND STATED THAT ONE OF THE SIDES OF THE PRODUCT WAS BURR WHICH MADE THE INSERTION IMPOSSIBLE. THIS CAUSED A 1-HOUR SURGICAL DELAY AND THE SURGEON HAD TO USE A TC3 INSERT CONFIRMING ADVERSE CONSEQUENCES OCCURRED TO THE PATIENT. THIS EVENT OCCURRED DURING PRIMARY SURGERY ON THE RIGHT SIDE.

    Patient problems: Insufficient Information

    MAUDE report 17369847 ↗
  • InjuryAug 16, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT UNDERWENT POLY EXCHANGE DUE TO INFECTION. DOI: (B)(6) 2020, DOR: (B)(6) 2022, AFFECTED SIDE: LEFT KNEE.

    Patient problems: Unspecified Infection

    MAUDE report 15232940 ↗
  • MalfunctionMay 31, 2022Difficult to Insert; Difficult to Insert

    IT WAS REPORTED THAT THE IMPLANT WAS NOT FITTED AS IT SHOULD, SO HE REQUESTED THE OPENING OF ANOTHER UNIT OF THE SAME CODE. 5 MINUTE DELAY.

    Patient problems: Insufficient Information

    MAUDE report 14547210 ↗
  • InjurySep 2, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS REVISED TO ADDRESS PAIN. DOI: UNKNOWN, DOR: (B)(6) 2020, LEFT KNEE.

    Patient problems: No Code Available; Pain

    MAUDE report 10482910 ↗
  • InjuryJan 15, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS REVISED DUE TO INFECTION. I&D WITH POLY EXCHANGE WAS PERFORMED. DOI: UNKNOWN; DOR: (B)(6) 2019; LEFT KNEE.

    Patient problems: No Code Available; Unspecified Infection

    MAUDE report 9591445 ↗
  • InjuryNov 8, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT WAS REVISED TO ADDRESS KNEE WAS BELIEVED TO BE INFECTED. COMPONENTS REMOVED AND REPLACED IN A ONE STAGE REVISION WITH PLACEMENT OF ANTIBIOTIC BEADS. NO LOT AVAILABLE FOR CEMENT AS IT IS HOSPITAL INVENTORY. DOI: (B)(6) 2019, DOR: (B)(6) 2019 LEFT KNEE.

    Patient problems: No Code Available; Unspecified Infection

    MAUDE report 9297339 ↗
  • InjuryMay 17, 2018Noise, Audible; Noise, Audible

    PATIENT PRESENTED IN CLINIC WITH A UNSTABLE LEFT KNEE, ¿CLICKING¿, AND MEDIAL PAIN. DR. (B)(6) DECIDED A FULL REVISION WAS BEST CORRECTIVE ACTION. DR. (B)(6) REMOVED FEMUR, INSERT, AND TIBIA AND REPLACED WITH REVISION COMPONENTS. THERE WAS NO LOOSENING OF THE COMPONENTS. THERE WAS NO MENTION OF THE PRODUCTS NOT DOING WHAT THEY WERE SUPPOSED TO. NO INSTRUMENTATION BROKE DURING SURGERY AND THERE WERE NO DELAYS. INDEX SURGERY WAS PERFORMED BY DR. (B)(6) AT (B)(6) COMMUNITY HOSPITAL ON (B)(6) 2012. DR. (B)(6) ELECTED TO KEEP THE PATELLA IMPLANTED.

    Patient problems: No Code Available; Not Applicable; Pain

    MAUDE report 7522356 ↗

Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page