The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10603295077152), received between Dec 6, 2017 and Dec 22, 2025 — classified as 4 injuries.
The most frequently reported specific device problem is “Loss of Osseointegration” (1 report).
3 other recalls cover devices cleared under the same FDA submission (K102080); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Loss of Osseointegration1
- Migration1
- Osseointegration Problem1
Patient problems
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available2
- Inadequate Osseointegration2
- Limb Fracture1
- Pain1
- Unspecified Infection1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryDec 22, 2025Osseointegration Problem; Migration; Osseointegration Problem; Migration
IT WAS REPORTED THAT RECLAIM PRX BDY CONE 20X85, RECLAIM DISTAL TAPERED 14X190A, BI MENTUM ALTRX LNR 49 28, AND DELTA CER HEAD 12/14 28MM +5 WERE INVOLVED IN A REPORTED EVENT. THE EVENT CONCERNED REVISION OF A RECLAIM STEM DUE TO LOOSENING, WITH THE STEM DESCRIBED AS UNDERSIZED AND HAVING SUBSIDED, RESULTING IN THE DISTAL TIP PROTRUDING THROUGH THE LATERAL CORTEX. THE EVENT REQUIRED A CORRECTIVE INVASIVE PROCEDURE IN WHICH THE DEVICE WAS REPLACED OR REVISED. OTHER THAN THE NEED FOR REVISION, THERE WERE NO ADDITIONAL ADVERSE CONSEQUENCES REPORTED.
Patient problems: Inadequate Osseointegration; Limb Fracture
MAUDE report 23862642 ↗InjurySep 22, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT PRESENTED WITH AN INFECTION. THE PATIENT WENT THROUGH SEVERAL I&DS AND WOULD NOT GET BETTER. THE SURGEON DECIDED TO DO A HIP DISARTICULATION. THE STEM, LINER AND CUP HAD TO COME OUT. THERE WERE NO INSTRUMENTS BROKEN OR DAMAGED. ALL COMPONENTS WERE REMOVED. DOI: (B)(6) 2021 - DOR: (B)(6) 2021 (LEFT HIP).
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Unspecified Infection
MAUDE report 12517272 ↗InjuryJun 4, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT PATIENT WAS ALSO OPERATED ON ON (B)(6) 2017. AN DER WAS REPORTED AT THAT TIME PATIENT HAS HISTORY OF RECURRENT INFECTION AND SEVERE PSORIATIC ARTHRITIS. PATIENT PRESENTS WITH PAIN AND XRAYS REVEALING VISIBLE GAS IN XRAYS, LEADING SURGEON TO BELIEVE PATIENT IS INFECTED. ALL COMPONENTS EXCEPT THE CUP WERE REMOVED. SURGEON FELT THAT IF THE CUP WERE REMOVED, THERE WAS NOT ENOUGH BONE TO PLACE ANOTHER SHELL INTO. A THOROUGH DEBRIDEMENT AND SUBSEQUENT IRRIGATION WAS PERFORMED. A NEW SET UP WAS UTILIZED TO REIMPLANT THE PATIENT ALONG WITH PLACEMENT OF ANTIBIOTIC BEADS. SURGEON ALSO COATED EXPOSED IMPLANTS WITH HIGH DOSE ANTIBIOTIC CEMENT. DOI: (B)(6) 2017 DOR: (B)(6) 2021 LEFT HIP.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Pain
MAUDE report 11938977 ↗InjuryDec 6, 2017Loss of Osseointegration; Loss of Osseointegration
THE PATIENT WAS REVISED TO ADDRESS INSTABILITY AND FEMORAL STEM LOOSENING AT THE BONE/IMPLANT INTERFACE.
Patient problems: Inadequate Osseointegration
MAUDE report 7088100 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K102080. One submission often covers many models, so check the product and lot details in each record.
- Z-2084-2014 · Jun 3, 2014 · TerminatedRECLAIM DISTAL TAPERED Distal Stem, various sizes. Taper Protector Sleeve. RECLAIM Revision Hip System Orthopedic Manual Surgical Instrument, used to ensure the locking taper surf
- Z-2083-2014 · Jun 3, 2014 · TerminatedRECLAIM DISTAL TAPERED, Angled Distal Stem, various sizes. Taper Protector Sleeve. RECLAIM Revision Hip System Orthopedic Manual Surgical Instrument, used to ensure the locking ta
- Z-2082-2014 · Jun 3, 2014 · TerminatedRECLAIM Taper Protector Sleeve. RECLAIM Revision Hip System Orthopedic Manual Surgical Instrument, used to ensure the locking taper surface of the Distal Stem is protected during
Other Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices
- BIOLOX DELTA 1365-32-310Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented551 reports
- PINNACLE ALTRX 1221-36-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented481 reports
- BIOLOX DELTA 1365-32-320Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death314 reports
- BIOLOX DELTA 1365-36-720Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death189 reports
- DJO SURGICAL 400-03-362Encore Medical, L.P. · Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented187 reports
- Anthology 71365705Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented176 reports
- BIOLOX DELTA 1365-40-710Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented170 reports
- PINNACLE GRIPTION 1217-32-054Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented169 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page