SIGMA 2011-03-009Recalls & reported problems
Depuy (Ireland) · SIGMA HP REVISION INSTRUMENTS NOTCH GUIDE SIZE 5 · Class 1
All models of SIGMA (380)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10603295081302), received between Jan 27, 2020 and Jun 4, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Device-Device Incompatibility” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device-Device Incompatibility2
- Break1
- Physical Resistance/Sticking1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 4, 2025Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT THE HEADED PIN DRIVER STUCK IN THE SZ 5 NOTCH GUIDE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22140801 ↗MalfunctionJan 22, 2021Break; Break
IT WAS REPORTED THAT THE SCREW LEVER ON FRONT RIGHT OF NOTCH BLOCK BROKE OFF, ONE PIECE. DISCARDED BY OPERATING ROOM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11214852 ↗MalfunctionJan 27, 2020Device-Device Incompatibility; Physical Resistance/Sticking; Device-Device Incompatibility; Physical Resistance/Sticking
DURING THE CASE A PIN GOT STUCK ONTO A SIZE 5 SIGMA HP FEMORAL NOTCH GUIDE. THE THREADS ON THE PIN PREVENTED THE SCRUB NURSE TO DISENGAGE THE TWO ITEMS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9634621 ↗
Other TEMPLATE devices
- ATTUNE 2544-01-014Depuy (Ireland) · TEMPLATE802 reports
- ATTUNE 2545-00-546Depuy (Ireland) · TEMPLATE1 recall301 reports
- ARTICUL/EZE 2531-51-000Depuy (Ireland) · TEMPLATE323 reports
- DELTA XTEND 2307-95-000Depuy (Ireland) · TEMPLATE315 reports
- ATTUNE 2545-00-547Depuy (Ireland) · TEMPLATE1 recall231 reports
- ATTUNE 2544-00-520Depuy (Ireland) · TEMPLATE279 reports
- ATTUNE 2545-00-545Depuy (Ireland) · TEMPLATE1 recall221 reports
- ARTICUL/EZE 2530-91-000Depuy (Ireland) · TEMPLATE271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page