DELTA XTEND 2307-82-001Recalls & reported problems

Depuy (Ireland) · DELTA Xtend DELTA CTA HEAD REAMING GUIDE · Class 1

All models of DELTA XTEND (194)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
10
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 10603295116349), received between Aug 18, 2017 and May 13, 2026 — classified as 1 injury, 9 malfunctions.

The most frequently reported specific device problem is “Device-Device Incompatibility” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility6
  • Mechanical Jam4
  • Naturally Worn2
  • Adverse Event Without Identified Device or Use Problem1
  • Bent1
  • Connection Problem1
  • Material Deformation1
  • Scratched Material1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • No Consequences Or Impact To Patient2
  • Bone Fracture(s)1
  • Insufficient Information1
  • No Code Available1
  • No Information1
  • Not Applicable1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 13, 2026Device-Device Incompatibility; Scratched Material

    IT WAS REPORTED THAT THE CTA HEAD REAMER AND GUIDE WERE SCORED AND BECAME BOUND TOGETHER. SURGEON FINISHED THE BONE PREPARATION BY HAND.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25164946 ↗
  • MalfunctionNov 13, 2024Device-Device Incompatibility; Material Deformation; Device-Device Incompatibility; Material Deformation

    ADDITIONAL INFORMATION WAS RECEIVED AND STATED THAT THERE WAS NO REPORTED PATIENT HARM.

    Patient problems: Insufficient Information

    MAUDE report 20679026 ↗
  • MalfunctionJul 1, 2022Naturally Worn; Naturally Worn

    IT WAS REPORTED THAT INSTRUMENTS WERE HIGHLY WORN AND NEEDED TO BE REPLACED. THERE WAS NO SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14885781 ↗
  • MalfunctionJul 1, 2022Naturally Worn; Naturally Worn

    IT WAS REPORTED THAT INSTRUMENTS WERE HIGHLY WORN AND NEEDED TO BE REPLACED. THERE WAS NO SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14885756 ↗
  • MalfunctionJun 28, 2021Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT THE CTA REAMER WAS WELDED ONTO THE REAMER GUIDE. SURGERY WAS NOT EXTENDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12080839 ↗
  • MalfunctionApr 8, 2021Device-Device Incompatibility; Mechanical Jam; Device-Device Incompatibility; Mechanical Jam

    SURGEON HAD CONVERTED TO EXTEND CTA DUE TO POOR GLENOID BONE QUALITY. WHEN HE ATTEMPTED TO PUT DELTA EXTEND CTA HEAD REAMER INTO THE REAMER GUIDE IT WOULD NOT FIT IN ALL THE WAY. SURGEON ATTEMPTED TO BEGIN REAMING AND IT STUCK AND ROTATED THE WHOLE CONSTRUCT, STEM, HEAD REAMER GUIDE AN REAMER. SURGICAL DELAY 10 MINUTES. SURGEON COMPLETED BONE REMOVAL WITH RONGEUR, PROCEDURE SUCCESSFULLY COMPLETED. NO PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11633355 ↗
  • MalfunctionSep 14, 2020Mechanical Jam; Mechanical Jam

    DELTA XTEND: DURING THE CASE, CTA REAMING GUIDE JAMMED WITH THE CTA REAMER. CAUSING THE REAMER TO NOT SPIN IN THE REAMING GUIDE. REAMING GUIDE REMOVED WITH REAMER AND THE CASE CONTINUED AS PER NORMAL. NO TIME ADDED TO THE CASE AS THE INSTRUMENT WAS DONE WITH AT THAT STAGE. WAS VERY DIFFICULT AND TOOK A LOT OF EFFORT TO REMOVE THE REAMER FROM THE REAMING GUIDE - DONE WITH A HAMMER. NO ADVERSE OUTCOMES EXPECTED. NO PATIENT DEMOGRAPHIC IS AVAILABLE. INSTRUMENT SEPARATED AND STERIBAGGED INDIVIDUALLY READY FOR RETURN.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10532212 ↗
  • MalfunctionJul 23, 2020Device-Device Incompatibility; Mechanical Jam; Device-Device Incompatibility; Mechanical Jam

    THE CTA REAMER GOT STUCKED TO THE CTA REAMERGUIDE AFTER REAMING.

    Patient problems: No Code Available; No Consequences Or Impact To Patient

    MAUDE report 10315584 ↗
  • InjuryJan 16, 2019Device-Device Incompatibility; Adverse Event Without Identified Device or Use Problem; Device-Device Incompatibility; Adverse Event Without Identified Device or Use Problem

    DURING PREPARATION OF THE PROXIMAL HUMERUS FOR THE CTA HEAD THE REAMER GUIDE WAS MOUNTED ON TO THE HUMERAL STEM. WHILE REAMING WITH THE CTA-HEAD-REAMER, THE REAMER SUDDENLY BLOCKED IN THE REAMER-GUIDE. THIS TURNED PRESSURE ON THE HUMERAL STEM AND GENERATED A FRACTURE OF THE PROXIMAL HUMERUS. THIS FRACTURE HAD TO BE FIXED WITH SUTURES. THE OPERATION COULD BE COMPLETED.

    Patient problems: Bone Fracture(s); Not Applicable

    MAUDE report 8252976 ↗
  • MalfunctionAug 18, 2017Bent; Connection Problem; Mechanical Jam; Bent; Connection Problem; Mechanical Jam

    IT WAS REPORTED THAT THE SURGEON ATTEMPTED TO IMPLANT AN XTEND CTA HEAD. WHEN REAMING THE LATERAL PROXIMAL HUMERUS, THE REAMER GOT STUCK ON THE GUIDE AND COULD NOT BE REMOVED.

    Patient problems: No Information

    MAUDE report 6805137 ↗

Other TEMPLATE devices

All TEMPLATE devices →