NA 2531-07-000Recalls & reported problems
Depuy (Ireland) · 12/14 ARTICULEZE TRIAL 40mm +8.5 · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 16
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 10603295129073), received between Mar 30, 2020 and Jun 20, 2025 — classified as 16 malfunctions.
The most frequently reported specific device problem is “Naturally Worn” (12 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Naturally Worn12
- Scratched Material8
- Break4
- Crack4
- Peeled/Delaminated2
- Material Twisted/Bent1
Patient problems
- No Clinical Signs, Symptoms or Conditions10
- No Consequences Or Impact To Patient6
Recent adverse event reports
The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 20, 2025Break; Break
IT WAS REPORTED THAT THE INSTRUMENT IS BROKEN. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22302254 ↗MalfunctionJan 3, 2024Naturally Worn; Scratched Material; Naturally Worn; Scratched Material
COMPLAINT IS RELATED TO (B)(4). THIS COMPLAINT WAS CREATED DUE TO THE EXCESS IMPACTED PRODUCTS IN (B)(4). DAMAGED PLASTIC FEMORAL HEAD TRIALS - NEED REPLACEMENT. PLASTIC IS WORN AND SCRATCHED ON HEAD TRIALS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18434844 ↗MalfunctionJan 3, 2024Naturally Worn; Scratched Material; Naturally Worn; Scratched Material
COMPLAINT IS RELATED TO (B)(4).. THIS COMPLAINT WAS CREATED DUE TO THE EXCESS IMPACTED PRODUCTS IN (B)(4). DAMAGED PLASTIC FEMORAL HEAD TRIALS - NEED REPLACEMENT PLASTIC IS WORN AND SCRATCHED ON HEAD TRIALS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18434841 ↗MalfunctionJan 3, 2024Naturally Worn; Scratched Material; Naturally Worn; Scratched Material
COMPLAINT IS RELATED TO (B)(4). THIS COMPLAINT WAS CREATED DUE TO THE EXCESS IMPACTED PRODUCTS IN (B)(4). DAMAGED PLASTIC FEMORAL HEAD TRIALS - NEED REPLACEMENT PLASTIC IS WORN AND SCRATCHED ON HEAD TRIALS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18434838 ↗MalfunctionNov 21, 2023Break; Naturally Worn; Scratched Material; Break; Naturally Worn; Scratched Material
IT WAS REPORTED THAT THE FEMORAL TRIAL HEAD HAS DAMAGED PLASTIC POSSIBLY SHEDDING PLASTIC SHARDS. NO PATIENT CONSEQUENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18180867 ↗MalfunctionNov 21, 2023Break; Naturally Worn; Scratched Material; Break; Naturally Worn; Scratched Material
IT WAS REPORTED THAT THE FEMORAL TRIAL HEAD HAS DAMAGED PLASTIC POSSIBLY SHEDDING PLASTIC SHARDS. NO PATIENT CONSEQUENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18180850 ↗MalfunctionNov 21, 2023Break; Naturally Worn; Scratched Material; Break; Naturally Worn; Scratched Material
IT WAS REPORTED THAT THE FEMORAL TRIAL HEAD HAS DAMAGED PLASTIC POSSIBLY SHEDDING PLASTIC SHARDS. NO PATIENT CONSEQUENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18180840 ↗MalfunctionFeb 8, 2023Peeled/Delaminated; Naturally Worn; Peeled/Delaminated; Naturally Worn
IT WAS REPORTED THAT THE TRIAL HEADS WERE WORN TO THE POINT THE PLASTIC WAS FLAKING OFF.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16325573 ↗MalfunctionFeb 8, 2023Peeled/Delaminated; Naturally Worn; Peeled/Delaminated; Naturally Worn
IT WAS REPORTED THAT THE TRIAL HEADS WERE WORN TO THE POINT THE PLASTIC WAS FLAKING OFF.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16325557 ↗MalfunctionMay 6, 2021Material Twisted/Bent; Material Twisted/Bent
IT WAS REPORTED THAT WORN INSTRUMENTS IDENTIFIED BY SPD AS NEEDING TO BE REPLACED. NO SURGICAL DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11783870 ↗MalfunctionOct 21, 2020Crack; Naturally Worn; Crack; Naturally Worn
IT WAS REPORTED THAT THE HEADS ARE IN A BAD SHAPE. PLASTIC IS CUT FROM RETRACTS AND INSTRUMENTS. NO SURGICAL DELAY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10711285 ↗MalfunctionOct 21, 2020Crack; Naturally Worn; Crack; Naturally Worn
IT WAS REPORTED THAT THE HEADS ARE IN A BAD SHAPE. PLASTIC IS CUT INTO FROM RETRACTS AND INSTRUMENTS. NO SURGICAL DELAY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10711284 ↗MalfunctionOct 21, 2020Crack; Naturally Worn; Crack; Naturally Worn
IT WAS REPORTED THAT THE HEADS ARE IN A BAD SHAPE. PLASTIC IS CUT FROM RETRACTS AND INSTRUMENTS. NO SURGICAL DELAY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10711283 ↗MalfunctionOct 21, 2020Crack; Naturally Worn; Crack; Naturally Worn
IT WAS REPORTED THAT THE HEADS ARE IN A BAD SHAPE. PLASTIC IS CUT FROM RETRACTS AND INSTRUMENTS. NO SURGICAL DELAY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10711282 ↗MalfunctionMar 30, 2020Scratched Material; Scratched Material
IT WAS REORTED THAT THE 32 + 40MM HEAD TRIALS NEED REPLACED DUE TO SCRATCHES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9901012 ↗MalfunctionMar 30, 2020Scratched Material; Scratched Material
IT WAS REORTED THAT THE 32 + 40MM HEAD TRIALS NEED REPLACED DUE TO SCRATCHES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9901007 ↗
Other TEMPLATE devices
- ATTUNE 2544-01-014Depuy (Ireland) · TEMPLATE802 reports
- ATTUNE 2545-00-546Depuy (Ireland) · TEMPLATE1 recall301 reports
- ARTICUL/EZE 2531-51-000Depuy (Ireland) · TEMPLATE323 reports
- DELTA XTEND 2307-95-000Depuy (Ireland) · TEMPLATE315 reports
- ATTUNE 2545-00-547Depuy (Ireland) · TEMPLATE1 recall231 reports
- ATTUNE 2544-00-520Depuy (Ireland) · TEMPLATE279 reports
- ATTUNE 2545-00-545Depuy (Ireland) · TEMPLATE1 recall221 reports
- ARTICUL/EZE 2530-91-000Depuy (Ireland) · TEMPLATE271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page