S-ROM 2576-11-100Recalls & reported problems

Depuy (Ireland) · S-ROM DISTAL STEM TRIAL, STANDARD SIZE 11 · Class 1

All models of S-ROM (185)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
15
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 10603295146063), received between Sep 14, 2017 and Apr 11, 2026 — classified as 15 malfunctions.

The most frequently reported specific device problem is “Device-Device Incompatibility” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility5
  • Illegible Information3
  • Material Twisted/Bent3
  • Material Deformation2
  • Naturally Worn2
  • No Apparent Adverse Event2
  • Appropriate Device Problem Term/Code Not Available1
  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions9
  • No Consequences Or Impact To Patient2
  • No Information2
  • Insufficient Information1
  • No Code Available1

Recent adverse event reports

The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 11, 2026No Apparent Adverse Event

    IT WAS REPORTED THAT THESE PRODUCTS HAD REACHED END OF LIFE DUE TO WEAR AND TEAR. THE SURGEONS COMPLAINED THAT INSTRUMENTS WERE DULL, ILLEGIBLE, AND GENERALLY WORN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24846149 ↗
  • MalfunctionNov 17, 2025Device-Device Incompatibility; Material Deformation; Device-Device Incompatibility; Material Deformation

    IT WAS REPORTED THAT REAMER SHAFT WOULD NOT FIT INTO THE REAMER ADAPTER, AND IT LOOKED BENT. IT WAS FURTHER OBSERVED THAT THE NECK TRIAL AND STEM TRIAL WOULD NOT SCREW TOGETHER AND SEEM TO BE STRIPPED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23576007 ↗
  • MalfunctionOct 22, 2025No Apparent Adverse Event; Illegible Information; No Apparent Adverse Event; Illegible Information

    IT WAS REPORTED THAT THE SROM TRIALS ARE TOO WORN AND DIFFICULT TO READ. NO SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23362466 ↗
  • MalfunctionFeb 25, 2025Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT INSTRUMENTS WOULD NOT TIGHTEN TOGETHER FOR TRIALING FROM THE SROM HIP INSTRUMENT HIT WHICH MADE THE CASE VERY DIFFICULT FOR SURGEON AND ADDED TIME. THE NECK TRIAL WOULDN'T TIGHTEN TO THE STEM TRIAL, AND THE SURGEON HAD GREAT DIFFICULTY IN TRIALING. THERE WAS NO PATIENT CONSEQUENCE.

    Patient problems: Insufficient Information

    MAUDE report 21459615 ↗
  • MalfunctionSep 7, 2023Material Deformation; Naturally Worn; Material Deformation; Naturally Worn

    IT WAS REPORTED THAT S-ROM DISTAL STEM TRIAL (11MM) IS GOUGED. DID THE EVENT OCCUR DURING FIELD INSPECTION? NO. DID THE EVENT OCCUR DURING INTERNAL SERVICE ACTIVITIES SUCH AS CALIBRATION? NO. PATIENT STATUS/ OUTCOME / CONSEQUENCES : NO. WAS OTHER MEDICAL INTERVENTION (E.G. X-RAYS, ADDITIONAL PROCEDURES, PRESCRIPTIONS, OTC, REVISION) REQUIRED: UNKNOWN. IS THE PATIENT PART OF A CLINICAL STUDY: UNKNOWN. (B)(6). DEVICE PROPERTY OF: NONE. DEVICE IN POSSESSION OF: NONE. BY CHECKING THIS BOX I CERTIFY THAT ALL INFORMATION THAT ARE KNOWN/AVAILABLE HAS BEEN DISCLOSED. IF ANY NEW INFORMATION WILL BE MADE AVAILABLE, THE ADDITIONAL INFORMATION WILL BE SUBMITTED THROUGH CST. TRUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17697592 ↗
  • MalfunctionApr 19, 2023Corroded; Corroded

    DEVICES APPEAR RUSTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16767562 ↗
  • MalfunctionJan 4, 2022Device-Device Incompatibility; Naturally Worn; Device-Device Incompatibility; Naturally Worn

    IT WAS REPORTED THAT THE END WITH LOCKING GROOVES IS STRIPPED AND WILL NOT LOCK WITH NECK. NO SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13151063 ↗
  • MalfunctionAug 23, 2021Material Integrity Problem; Material Integrity Problem

    INSTRUMENTS DAMAGED FROM PREVIOUS SROM CASES. FOUND TO BE DAMAGED AT THE CASE. X2 DAMAGED SLEEVE TRIALS NEED REPLACING -DAMAGED. X1 11X16 STEM TRIAL NEEDS REPLACING -DAMAGED. X1 PLASTIC FRAME SLEEVE NEEDS REPLACING -IS LOST.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12356541 ↗
  • MalfunctionApr 13, 2021Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent

    IT WAS REPORTED THAT WHILE SURGERY WAS TAKING PLACE, THE PRODUCTS LISTED BELOW WERE ALL TRIALED AND SHOWED SIGNS OF DYSFUNCTION. NEITHER THE BODIES OR THE STEMS WOULD FULLY LOCKED DOWN AND CONNECT TO EACH OTHER. SOME OF THE BODY SHOWED SIGNS OF THREADED THREADS. SURGERY WAS DELAYED. THERE WERE NO PARTS BROKEN OFF.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11657073 ↗
  • MalfunctionFeb 11, 2021Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent

    ADDITIONAL INFORMATION RECEIVED INDICATED THAT THE DEVICE WAS STRIPPED. THERE WAS NO SURGICAL DELAY AND NO PIECES WERE BROKEN OFF FROM THE INSTRUMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11313919 ↗
  • MalfunctionFeb 20, 2020Illegible Information; Illegible Information

    IT WAS REPORTED THAT THE SIZES OF THE SROM INSTRUMENTS WERE DIFFICULT OR IMPOSSIBLE TO READ. NO SURGICAL DELAY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9734654 ↗
  • MalfunctionFeb 20, 2020Material Twisted/Bent; Illegible Information; Material Twisted/Bent; Illegible Information

    IT WAS REPORTED THAT THE INSTRUMENT WERE DIFFICULT OR IMPOSSIBLE TO READ ETCHING DUE TO WEAR AND TEAR OVER THE YEARS. THE SURGEON IS CONCERNED ABOUT THE PATIENT SAFETY ISSUE AND THE INSTRUMENTS NEED TO BE REPLACED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9732499 ↗
  • MalfunctionSep 17, 2018Break; Break

    AT TRAILING PHASE, SURGEON WENT TO USE TRAIL AS PREPARED FOR. THIS WAS THE 16X11 TRIAL, WITH A 36 STANDARD NECK. THESE TWO ARE JOINED WITH A SCREW AND THREAD, AND INTERLOCK WITH TEETH ON BOTH COMPONENTS. TO CHANGE THE VERSION, THE NECK CAN BE ROTATED, AND THEN LOCKED ONTO THE STEM. HOWEVER THIS LOCKING MECHANISM WAS BROKEN, CAUSING SIGNIFICANT PROBLEMS AND DELAY TO SURGERY AS HE COULD NOT TRAIL THE STEM VERSION. TO COMPLETE THE PROCEDURE, THE SURGEON HAD TO OPEN THE DEFINITIVE IMPLANT AND APPROXIMATE IDEAL VERSION OF THE STEM. SURGEON INDICATED THIS IS NOT THE FIRST TIME IT HAS HAPPENED. A 30 MINUTE DELAY TO THE PROCEDURE.

    Patient problems: No Code Available

    MAUDE report 7880372 ↗
  • MalfunctionOct 4, 2017Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    DER STATES THAT THE STERILE PROCESSING CALLED THE REP TO COME TO THEM AND SAID THEY COULD NOT GET THESE TWO INSTRUMENTS APART. THEY TRIED SOAKING THEM OVER THE WEEKEND BUT IT DID NOT WORK. ALSO TRIED TO PRY THEM OPEN, IT DID NOT WORK. DID NOT KNOW THEY WERE STUCK TOGETHER UNTIL TUESDAY (B)(6) AFTER THE LONG WEEKEND. IT WAS STATED THAT IT WAS NOT BROKEN BUT JAMMED TOGETHER.

    Patient problems: No Information

    MAUDE report 6914647 ↗
  • MalfunctionSep 14, 2017Misconnection; Misconnection

    IT WAS REPORTED THAT THE STEM BODY TRIAL STRIPPED AND WON'T CONNECT TO THE NECK TRIALS AND NEED TO BE REPLACED.

    Patient problems: No Information

    MAUDE report 6864262 ↗