S-ROM 2576-30-000Recalls & reported problems
Depuy (Ireland) · S-ROM NECK TRIAL 30 STD · Class 1
All models of S-ROM (185)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 10603295147039), received between Apr 18, 2018 and Nov 17, 2025 — classified as 8 malfunctions.
The most frequently reported specific device problem is “Device-Device Incompatibility” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device-Device Incompatibility5
- Material Twisted/Bent4
- Appropriate Device Problem Term/Code Not Available1
- Loose or Intermittent Connection1
- Material Deformation1
- Naturally Worn1
Patient problems
- No Consequences Or Impact To Patient4
- No Clinical Signs, Symptoms or Conditions3
- No Code Available1
- Not Applicable1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 17, 2025Device-Device Incompatibility; Material Deformation; Device-Device Incompatibility; Material Deformation
IT WAS REPORTED THAT REAMER SHAFT WOULD NOT FIT INTO THE REAMER ADAPTER, AND IT LOOKED BENT. IT WAS FURTHER OBSERVED THAT THE NECK TRIAL AND STEM TRIAL WOULD NOT SCREW TOGETHER AND SEEM TO BE STRIPPED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23576013 ↗MalfunctionMar 16, 2023Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT THE 30 STD NECK NO LONGER LOCKS ONTO STEM TRIALS. IT JUST SPINS ON THE STEM TRIAL. NO SURGICAL DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16554084 ↗MalfunctionApr 13, 2021Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent
IT WAS REPORTED THAT WHILE SURGERY WAS TAKING PLACE, THE PRODUCTS LISTED BELOW WERE ALL TRIALED AND SHOWED SIGNS OF DYSFUNCTION. NEITHER THE BODIES OR THE STEMS WOULD FULLY LOCKED DOWN AND CONNECT TO EACH OTHER. SOME OF THE BODY SHOWED SIGNS OF THREADED THREADS. SURGERY WAS DELAYED. THERE WERE NO PARTS BROKEN OFF.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11657122 ↗MalfunctionAug 31, 2020Material Twisted/Bent; Material Twisted/Bent
THIS EVENT OCCURRED DURING "SALES TRAINING"; SA LOAN INSTRUMENT KIT = BROKEN INSTRUMENT. STANDARD NECK TRIAL FROM THE SROM INSTRUMENT LOAN KIT IS CROSS THREADING AND A REPLACEMENT IS REQUIRED PLEASE. ITEM: D25763000; LOT: MT0606 (CORRECT).
Patient problems: No Code Available; No Consequences Or Impact To Patient
MAUDE report 10471803 ↗MalfunctionFeb 25, 2020Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent
IT WAS REPORTED THAT THE TRIAL NECK DOES NOT ENGAGE WITH THE STEM. NEEDS REPLACEMENT TO LEYVA'S WH.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9752118 ↗MalfunctionDec 9, 2019Device-Device Incompatibility; Material Twisted/Bent; Naturally Worn; Device-Device Incompatibility; Material Twisted/Bent; Naturally Worn
MalfunctionSep 7, 2018Loose or Intermittent Connection; Loose or Intermittent Connection
IT WAS REPORTED THAT THE NECK WON¿T TIGHTEN TO STEM. NO SURGICAL DELAY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7854950 ↗MalfunctionApr 18, 2018Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT THE IMPACTOR HANDLE CRACKED AFTER YEARS OF USE. THE TWO NECK TRIALS ALSO STRIPPED AND IT WILL NOT STAY ON THE STEM TRIAL. NO SURGICAL DELAY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7439420 ↗
Other TEMPLATE devices
- ATTUNE 2544-01-014Depuy (Ireland) · TEMPLATE802 reports
- ATTUNE 2545-00-546Depuy (Ireland) · TEMPLATE1 recall301 reports
- ARTICUL/EZE 2531-51-000Depuy (Ireland) · TEMPLATE323 reports
- DELTA XTEND 2307-95-000Depuy (Ireland) · TEMPLATE315 reports
- ATTUNE 2545-00-547Depuy (Ireland) · TEMPLATE1 recall231 reports
- ATTUNE 2544-00-520Depuy (Ireland) · TEMPLATE279 reports
- ATTUNE 2545-00-545Depuy (Ireland) · TEMPLATE1 recall221 reports
- ARTICUL/EZE 2530-91-000Depuy (Ireland) · TEMPLATE271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page