S-ROM 52-3393Recalls & reported problems

Depuy (Ireland) · S-ROM Total Hip System FEMORAL STEM Standard 42 STD NECK 11/13 TAPER 18x13x160 · Class 3 · Implant

All models of S-ROM (185)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
22
Deaths reported
0
Injuries reported
22
Recalls naming it
0

Summary

The FDA's MAUDE database contains 22 adverse event reports that list this exact device (DI 10603295170990), received between Jan 9, 2017 and Mar 18, 2024 — classified as 22 injuries.

The most frequently reported specific device problem is “Osseointegration Problem” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem9
  • Osseointegration Problem4
  • Biocompatibility3
  • Degraded2
  • Insufficient Device Problem Information2
  • Corroded1
  • Fracture1
  • Migration1

Patient problems

  • Pain13
  • No Code Available8
  • Test Result7
  • Foreign Body Reaction6
  • Unspecified Infection5
  • Discomfort4
  • Inadequate Osseointegration4
  • Tissue Damage3

Recent adverse event reports

The 22 most recent of 22 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 18, 2024Migration; Migration

    IT WAS REPORTED THAT PATIENT WAS REVISED DUE TO STEM SUBSIDENCE AND REMOVED SROM STEM AND SLEEVE AND REVISED TO RECLAIM MOD STEM. IT WAS UNKNOWN THAT THERE WAS ANY SURGICAL DELAY. DOI: ON (B)(6) 2021, DOR: ON (B)(6) 2024, AFFECTED SIDE: UNKNOWN HIP.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 18920637 ↗
  • InjuryJul 8, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CONTACTED PATIENT VIA PHONE. PATIENT ANSWERED. LEFT HIP WAS IMPLANTED WITH PINNACLE IN (B)(6) 2004 AND RIGHT HIP WAS IMPLANTED WITH PINNACLE IN (B)(6) 2004. IN 2021 SHE HAD PAIN AND ELEVATED METAL ION LEVELS AND WAS RECOMMENDED FOR REVISION SURGERY AND HAS UNDERGONE THE REVISION. PATIENT WAS INTERESTED IN IF THE IMPLANTS WERE INVOLVED IN A RECALL. PATIENT WAS INFORMED PINNACLE WAS NOT PART OF THE ASR RECALL. PATIENT WAS INTERESTED IN COMPENSATION FOR THE REVISION SURGERIES. CONTACT INFORMATION WAS PROVIDED FOR THE LEGAL TEAM AND LEGAL TEAM WAS EMAILED THROUGH ECM. DOI: (B)(6) 2004. DOR: UNKNOWN. AFFECTED SIDE: RIGHT HIP.

    Patient problems: Metal Related Pathology; Pain

    MAUDE report 14955307 ↗
  • InjuryMay 5, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PINNACLE MEDICAL RECORDS RECEIVED. AFTER REVIEW OF THE MEDICAL RECORDS, POST REVISION CLINICAL VISIT REPORTED PAIN IN LEFT GROIN, LOWER BACK, WEAKNESS, NUMBNESS SENSATION, FLEXOR TENDINITIS, BONE LOSS IN THE PROXIMAL PORTION OF THE FEMUR, LOCAL TISSUE REACTION, ONGOING ILIOPSOAS TENDINOPATHY. X-RAYS REVEALED HETEROTOPIC BONY FORMATION ON THE GREATER TROCHANTER. DOI: JUN 11, 2018 ; DOR: UNKNOWN; LEFT HIP.

    Patient problems: Ambulation or Postural Difficulties; Calcium Deposits/Calcification; Extraskeletal ossification; Fatigue; Foreign Body Reaction; Limb Fracture; Loss of Range of Motion; Muscle/Tendon Damage; Pain; Unspecified Tissue Injury

    MAUDE report 14286703 ↗
  • InjuryJan 31, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION COMPLETED DUE TO INFECTION. PATIENT HAS UNDERGONE A FEW OTHER REVISIONS. DOI: SEVERAL YEARS AGO (STEM, CUP), DOI: (B)(6) 2021 (HEAD, LINER), DOR: (B)(6) 2022, RIGHT HIP.

    Patient problems: Unspecified Infection

    MAUDE report 13393392 ↗
  • InjuryOct 1, 2021Osseointegration Problem; Osseointegration Problem

    PATIENT WAS REVISED DUE TO PAINFUL LEFT HIP AND LOOSENING OF THE STEM AT BONE TO IMPLANT INTERFACE. DOI: (B)(6) 2003, DOR: (B)(6) 2021, LEFT HIP.

    Patient problems: Inadequate Osseointegration; Pain

    MAUDE report 12561212 ↗
  • InjurySep 30, 2021Osseointegration Problem; Osseointegration Problem

    PATIENT WAS REVISED DUE TO PAINFUL LEFT HIP AND LOOSENING OF THE STEM AT BONE TO IMPLANT INTERFACE. DOI: (B)(6) 2003, DOR: (B)(6) 2021, LEFT HIP.

    Patient problems: Inadequate Osseointegration; Pain

    MAUDE report 12555076 ↗
  • InjurySep 28, 2021Osseointegration Problem; Osseointegration Problem

    PATIENT WAS REVISED DUE TO PAINFUL LEFT HIP AND LOOSENING OF THE STEM AT BONE TO IMPLANT INTERFACE. DOI: (B)(6) 2003, DOR: (B)(6) 2021, LEFT HIP.

    Patient problems: Inadequate Osseointegration; Pain

    MAUDE report 12539433 ↗
  • InjuryAug 24, 2021Osseointegration Problem; Osseointegration Problem

    PATIENT WAS REVISED DUE TO PAINFUL LEFT HIP AND LOOSENING OF THE STEM AT BONE TO IMPLANT INTERFACE. DOI: (B)(6) 2003, DOR: (B)(6) 2021, LEFT HIP.

    Patient problems: Inadequate Osseointegration; Pain

    MAUDE report 12360932 ↗
  • InjurySep 3, 2020Corroded; Degraded; Corroded; Degraded

    PFS ALLEGES THAT PATIENT COULD NOT WALK VERY WELL, LIMITED MOVEMENT OF ANY PHYSICAL ACTIVITY. X-RAYS RESULT STATED THAT THERE IS A FRACTURE FRAGMENT SEEN LATERAL TO THE FEMORAL NECK. DOI: (B)(6) 2007. DOR: (B)(6) 2018. LEFT HIP.

    Patient problems: Ambulation or Postural Difficulties; Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Discomfort; Foreign Body Reaction; Hypersensitivity/Allergic reaction; Limb Fracture; Loss of Range of Motion; No Code Available; Osteolysis; Pain; Synovitis; Test Result

    MAUDE report 10488338 ↗
  • InjuryJun 2, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PATIENT HAD VERY HIGH HIP CENTER ON PRIMARY HIP PERFORMED IN (B)(6) 2019 AND AT THAT TIME PATIENT WAS LEFT SHORT. TODAY, A LONGER STEM WAS PLACED TO GET THE PATIENT BACK CLOSER TO EQUAL LEG LENGTHS. DOI: (B)(6) 2019. DOR: (B)(6) 2020. RIGHT HIP.

    Patient problems: No Code Available

    MAUDE report 10111316 ↗
  • InjuryApr 13, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION RECEIVED THAT THE AFFECTED SIDE IS THE LEFT HIP.

    Patient problems: No Code Available; Unspecified Infection

    MAUDE report 9953665 ↗
  • InjuryMar 10, 2020Degraded; Degraded

    PINNACLE CLAIM SUBMISSION FORM AND MEDICAL RECORDS RECEIVED. AFTER REVIEW OF MEDICAL RECORDS, THE PATIENT WAS REVISED TO ADDRESS A FAILED LEFT TOTAL HIP ARTHROPLASTY WITH PAIN AND SIGNS OF METALLOSIS. OPERATIVE FINDINGS INCLUDE SEVERE REACTIVE METALLOSIS, SOFT TISSUE DAMAGE, EROSION, SIGNIFICANT AMOUNT OF WEAR ON THE SURFACE OF THE HEAD AND BLACK METALLIC APPEARING RUST OVER THE TRUNNION. SAMPLES TAKEN FROM A CYST AND PSEUDOTUMOR WERE SENT TO THE LABORATORY FOR ANALYSIS. PREOPERATIVELY, THE PATIENT WAS SLIGHTLY LONGER ON THE RIGHT. DOI: (B)(6) 2004; DOR: (B)(6) 2016; RIGHT HIP.

    Patient problems: Cyst(s); Foreign Body Reaction; Hypersensitivity/Allergic reaction; No Code Available; Pain; Pocket Erosion; Tissue Damage

    MAUDE report 9813622 ↗
  • InjuryJan 8, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PPF AND STICKER SHEETS RECEIVED. PPF ALLEGES METAL WEAR AND METALLOSIS. DOI: (B)(6) 2002 - DOR: NONE REPORTED (LEFT HIP).

    Patient problems: Foreign Body Reaction; Test Result

    MAUDE report 9565388 ↗
  • InjuryJan 8, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT WAS REVISED TO ADDRESS INFECTION AND PAIN. REVISION NOTES REPORTED SMALL AMOUNT OF CLOUDY SEROUS FLUID WITHIN THE BURSA AND DEEP TISSUES OF HIP CONSISTENT WITH SEROMA AND INFECTED SEROMA. PRIOR TO REVISION, THERE WAS NOTED SIGNIFICANT LOWER EXTREMITY EDEMA, SWELLING AND INABILITY TO AMBULATE. DOI: (B)(6) 2017 (HEAD & LINER). DOI: (B)(6) 2001 (CUP, STEM & SLEEVE). DOR: (B)(6) 2017 RIGHT HIP.

    Patient problems: Edema; No Code Available; Pain; Seroma; Unspecified Infection

    MAUDE report 9564532 ↗
  • InjurySep 25, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PPF AND MEDICAL RECORDS RECEIVED. THERE WERE NO NEW ALLEGATION REPORTED FROM PPF. AFTER REVIEW OF MEDICAL RECORDS, PATIENT WAS REVISED TO ADDRESS CHRONIC DISCOMFORT AND BURSITIS VERSUS ABDUCTOR TENDON TEARS BUT OPERATIVE NOTES REPORTED THAT ABDUCTOR TENDON APPEAR TO BE INTACT. REVISION NOTE REPORTED METALLOSIS AND THE POSTERIOR ASPECT OF THE FEMORAL NECK WAS IMPINGING ON THE RETAINING RING ON THE ACETABULAR COMPONENT. DOI: (B)(6) 2013; DOR: (B)(6) 2015; (LEFT HIP) THIRD REVISION. PLEASE SEE (B)(4) FOR THE FIRST REVISION. PLEASE SEE (B)(4) FOR THE SECOND REVISION.

    Patient problems: Discomfort; Foreign Body Reaction; Joint Disorder; No Code Available

    MAUDE report 9120571 ↗
  • InjuryJul 2, 2019Naturally Worn; Naturally Worn

    IT AS REPORTED THAT THE PATIENT HAS MULTI-LEVEL DEGENERATIVE CHANGES IN LUMBAR SPINE. USES NO WALKING AIDS TO AMBULATE. EXPERIENCED RIGHT HIP GROIN PAIN IN PREVIOUS MONTHS. THE TAPER ON THE FEMORAL STEM INDICATES MODERATE SIGNS OF WEAR. NO VISIBLE SIGNS OF METALLOSIS IN JOINT. ION STUDY ON (B)(6) 2019: CHROMIUM 2.1, COBALT 11.2, TITANIUM -. THE METAL INSERT AND FEMORAL HEAD WERE CHANGED. THE STEM HAS BEEN ADDED TO THE COMPLAINT DUE ELEVATED METAL IONS. DOI: (B)(6) 2004; DOR: (B)(6) 2019; RIGHT HIP.

    Patient problems: No Code Available; Pain; Test Result

    MAUDE report 8752844 ↗
  • InjuryApr 15, 2019Biocompatibility; Adverse Event Without Identified Device or Use Problem; Biocompatibility; Adverse Event Without Identified Device or Use Problem

    PPF ALLEGES METAL WEAR/METALLOSIS AND ELEVATED METAL IONS. DOI: (B)(6) 2002; DOR: (B)(6) 2012; (RIGHT SIDE).

    Patient problems: Test Result; Tissue Damage

    MAUDE report 8514094 ↗
  • InjuryApr 9, 2019Fracture; Fracture

    PPF ALLEGES INFECTION AND FRACTURE (COMPONENT). DOI: (B)(6) 2008 - DOR: (B)(6) 2013 (LEFT HIP).

    Patient problems: Discomfort; Inflammation; Pain; Test Result; Unspecified Infection

    MAUDE report 8497103 ↗
  • InjuryMar 14, 2019Biocompatibility; Biocompatibility

    PPF ALLEGES ELEVATED METAL IONS. DOI: (B)(6) 2008 - DOR: (B)(6) 2012 (RIGHT SIDE).

    Patient problems: Discomfort; Inflammation; Pain; Test Result

    MAUDE report 8419871 ↗
  • InjuryFeb 14, 2019Biocompatibility; Biocompatibility

    PATIENT REVISED FOR METALOSIS. UPDATE: 10/18/2012 PFS WAS RECEIVED FROM LEGAL, MEDICAL RECORDS WERE RECEIVED FROM LEGAL. UPDATE AD 12 JUN 2018 RECEIPT OF PPF AND STICKER SHEETS. IN ADDITION TO WHAT PREVIOUSLY ALLEGED, PPF ALLEGES PSEUDOTUMOR, METAL WEAR AND ELEVATED METAL IONS BEFORE FIRST REVISION. ADDED STEM TO ADDRESS ELEVATED METAL IONS.

    Patient problems: No Code Available; Test Result; Tissue Damage

    MAUDE report 8339271 ↗
  • InjuryJan 3, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    NEW UNITY RECORD CREATED IN ORDER TO UPDATE LEGACY COMPLAINT NUMBER (B)(4). LITIGATION ALLEGES THAT PATIENT EXPERIENCED HIP PAIN, CAUSING DIFFICULTY AMBULATING AND SLEEPING. ADDITIONALLY, IT IS ALLEGED THAT IMPLANT IS RELEASING METAL IONS INTO PATIENT'S BODY. UPDATE DEC 05, 2017: PFS AND MEDICAL RECORDS RECEIVED. PFS ALSO ALLEGES SUPERFICIAL THROMBOSIS, MUSCLE DAMAGE REQUIRING SURGICAL REPAIR, METALLOSIS AND PHYSICAL LIMITATIONS. AFTER REVIEW OF MEDICAL RECORDS FOR MDR REPORTABILITY, IT WAS STATED THAT THE PATIENT WAS REVISED TO ADDRESS PAIN, ELEVATED METAL IONS AND LARGE FLUID COLLECTIONS. REVISION NOTES REPORTED NO TISSUE AND BONE DESTRUCTION, CORROSIVE BLACK DEBRIS, METAL STAINING AND MINIMAL FLUID STAINING IN THE HIP. MRI REPORTED GREATER TROCHANTERIC BURSITIS. CLINIC NOTES REPORTED MUSCLE WEAKNESS AND STIFFNESS. ADDED SROM SLEEVE FOR THE REPORTED CORROSIVE BLACK DEBRIS. THIS COMPLAINT WAS UPDATED ON: DECEMBER 15, 2017. DOI: (B)(6) 2010, DOR: (B)(6) 2012 (RIGHT HIP).

    Patient problems: Foreign Body Reaction; Host-Tissue Reaction; Limited Mobility Of The Implanted Joint; Pain; Thrombosis; Weakness

    MAUDE report 7159756 ↗
  • InjuryJan 9, 2017Insufficient Device Problem Information; Insufficient Device Problem Information

    PATIENT WAS REVISED TO ADDRESS AN INFECTION.

    Patient problems: Unspecified Infection

    MAUDE report 6234214 ↗

Other Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented devices

All Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented devices →