S-ROM ZTT 55-0503Recalls & reported problems
Depuy (Ireland) · S-ROM Modular Hip System ZTT Proximal Sleeve POROUS COATED 14 D SML FITS: 14 x 09 OR 14 x 08 STEM Cone: D Triangle: SML · Class 3 · Implant
All models of S-ROM ZTT (36)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10603295175193), received between Jan 31, 2018 and Mar 15, 2022 — classified as 4 injuries, 1 malfunction.
The most frequently reported specific device problem is “Loss of Osseointegration” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Loss of Osseointegration2
- Osseointegration Problem1
Patient problems
- Hypersensitivity/Allergic reaction3
- Inadequate Osseointegration2
- Pain2
- Swelling/ Edema2
- Extraskeletal ossification1
- Foreign Body Reaction1
- Nerve Damage1
- No Code Available1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryMar 15, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
MOM MEDICAL RECORDS RECEIVED. AFTER REVIEW OF THE MEDICAL RECORDS, THE PATIENT WAS REVISED TO ADDRESS PSEUDOTUMOR, ELEVATED METAL IONS, NEUROLYSIS OF SCIATIC NERVE, COMPLEX WOUND OF HIP, HETEROTOPIC OSSIFICATION AND CAPSULAR REDUNDANCY. OPERATIVE NOTE REPORTED SCARS, METALLOSIS, PSEUDOTUMOR AND METALLIC DEBRIS. THERE WAS A LARGE AMOUNT OF FLUID PRESENT IN THE HIP JOINT, SCIATIC NERVE WAS COMPRESSED BY THE PSEUDOTUMOR. THERE WAS ALSO A LARGE AMOUNT OF CAPSULAR DEBRIS, PSEUDOTUMOR AND SOME HETEROTOPIC BONE. MEDICAL RECORDS INDICATE THE CUP WAS LOOSENED AND CYSTIC CHANGES WERE CURETTED FROM BEHIND THE CUP. DOI: (B)(6) 2009; DOR: (B)(6) 2012 ; RIGHT HIP.
Patient problems: Extraskeletal ossification; Foreign Body Reaction; Hypersensitivity/Allergic reaction; Nerve Damage; Pain; Scar Tissue; Swelling/ Edema
MAUDE report 13769631 ↗MalfunctionFeb 18, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THIS PC IS RELATED TO (B)(4) WHICH REPORTS ABOUT THE PRIMARY SURGERY VIA TKA. THIS PC REPORTS ABOUT THE REVISION SURGERY WAS PERFORMED DUE TO THE ACCUMULATION OF THE WATER IN PSEUDOTUMOR EXCISION SITE. AFTER THE REMOVAL SURGERY OF PSEUDOTUMOR PERFORMED IN (B)(6) 2021, IT WAS FOUND THAT THE ACCUMULATION OF THE WATER IN PSEUDOTUMOR EXCISION SITE. THE PATIENT WAS SUSPECTED OF HAVING AN INFECTION, SO THE REVISION SURGERY WAS PERFORMED ON (B)(6) 2021, AND THE IMPLANTS WERE REMOVED. THE SURGERY WAS COMPLETED SUCCESSFULLY WITHIN 30 MINUTES DELAY. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Hypersensitivity/Allergic reaction; Swelling/ Edema; Unspecified Infection
MAUDE report 13558366 ↗InjuryDec 2, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THIS PC IS RELATED TO (B)(4) WHICH REPORTS ABOUT THE REVISION SURGERY WAS PERFORMED DUE TO THE ACCUMULATION OF THE WATER IN PSEUDOTUMOR EXCISION SITE. THIS PC REPORTS ABOUT THE PRIMARY SURGERY. IT WAS REPORTED THAT ON UNKNOWN DATE, THE PATIENT UNDERWENT THE PRIMARY SURGERY VIA TKA, AND THE SURGERY WAS COMPLETED SUCCESSFULLY. AFTER THE PRIMARY SURGERY, ON AN UNKNOWN DATE, PSEUDOTUMOR WAS IDENTIFIED IN MUSCLE TISSUE. ON AN UNKNOWN DATE, (B)(6) 2021, THE PATIENT UNDERWENT THE REMOVAL SURGERY OF PSEUDOTUMOR, AND THE SURGERY WAS COMPLETED SUCCESSFULLY. NO FURTHER INFORMATION IS AVAILABLE. DOI: (B)(6) 2021.
Patient problems: Hypersensitivity/Allergic reaction
MAUDE report 12917198 ↗InjuryAug 22, 2019Loss of Osseointegration; Osseointegration Problem; Loss of Osseointegration; Osseointegration Problem
THE PRIMARY SURGERY WAS PERFORMED ON (B)(6) 2011 VIA THA. IT WAS REPORTED THAT THE PATIENT COMPLAINED PAIN AND THE STEM BREAKAGE WAS REVEALED BY X-RAY WHEN SHE VISITED TO THE HOSPITAL. THUS, THE REVISION SURGERY WAS PERFORMED ON (B)(6) 2019 BY REPLACING THE STEM (P/N: 900527210) WITH THE SLEEVE (P/N: 550503) TO SIZE 18-12 DUE TO PAIN, DISTAL-STEM BREAKAGE, LOOSENING OF THE SLEEVE. THE SURGERY WAS COMPLETED WITHOUT PROBLEM, AND THE SIZE OF THE SURGICAL WOUND WAS THE SAME AS THE PRIMARY SURGERY. IT WAS UNKNOWN WHETHER THERE WAS A SURGICAL DELAY OR NOT. DR¿S COMMENT: THE SLEEVE CAME OFF WITH THE STEM STUCK TOGETHER WHEN THE SURGEON ATTEMPTED TO REMOVE ONLY THE STEM, SO IT WAS CONSIDERED THAT THE STEM WAS BROKEN BY THE STRESS TO THE DISTAL END DUE TO THE LOOSENING OF THE SLEEVE. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Inadequate Osseointegration; No Code Available; Pain
MAUDE report 8920803 ↗InjuryJan 31, 2018Loss of Osseointegration; Loss of Osseointegration
PATIENT WAS REVISED TO ADDRESS LOOSENING OF THE FEMORAL COMPONENT AT BONE TO IMPLANT INTERFACE. DOI: (B)(6) 2015; DOR: (B)(6) 2018; UNKNOWN HIP.
Patient problems: Inadequate Osseointegration
MAUDE report 7230190 ↗
Other Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented devices
- BIOLOX DELTA 1365-36-310Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented839 reports
- BIOLOX DELTA 1365-36-320Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented643 reports
- PINNACLE POROCOAT 1217-22-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented335 reports
- PINNACLE POROCOAT 1217-22-054Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented263 reports
- BIOLOX DELTA 1365-36-330Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented255 reports
- PINNACLE POROCOAT 1217-22-050Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented253 reports
- PINNACLE POROCOAT 1217-22-056Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented220 reports
- SUMMIT POROCOAT 1570-11-120Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/ceramic/metal, cemented or uncemented1 death204 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page