Skip to content

P.F.C. SIGMA 96-0055Recalls & reported problems

Depuy (Ireland) · P.F.C. SIGMA FEMORAL CRUCIATE SUBSTITUTING CEMENTED 5 RIGHT · Class 2 · Implant

All models of P.F.C. SIGMA (487)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10603295232407), received between Aug 3, 2020 and Dec 13, 2022 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Loss of or Failure to Bond” (2 reports).

24 other recalls cover devices cleared under the same FDA submission (K241000, K950010, K952830, K971189); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Loss of or Failure to Bond2
  • Adverse Event Without Identified Device or Use Problem1
  • Difficult to Open or Close1

Patient problems

  • No Code Available2
  • Adhesion(s)1
  • Foreign Body Reaction1
  • Insufficient Information1
  • Not Applicable1
  • Pain1
  • Unspecified Infection1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 13, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    PATIENT UNDERWENT REVISION TKR AS PART OF A SECOND STAGE DUE TO INFECTION. PATIENT HAS PRESENTED TO DR DAVID LIU AND UNDERGONE A POLY EXCHANGE AND WASHOUT. AT THIS STAGE, ON OPENING THE KNEE, THE KNEE WAS OBVIOUSLY PUSS AND INFECTED. THE KNEE WAS WASHED OUT AND THE POLY BEARING EXCHANGED. SAMPLES TAKEN AT THIS STAGE ARE POSITIVE FOR BACTERIA (SENSITIVE STRAIN). A DECISION WAS MADE TO GO BACK INTO THE KNEE AND REMOVE ALL COMPONENTS AS PART OF A TWO STAGE PROCEDURE. ON OPENING THE KNEE IT APPEARED RELATIVELY ANGRY BUT NOT OVERTLY PUSS. THE COMPONENTS WERE REMOVED, THE TISSUE DEBRIDED AND A TEMPORARY "KIWI" SPACER IMPLANTED (ATTUNE PS FEMUR AND AN ATTUNE PS RP INSERT) AS PART OF THE TEMPORARY SPACER. THESE WILL BE REMOVED IN DUE COURSE AND EXCHANGED FOR A REVISION SYSTEM.

    Patient problems: Unspecified Infection

    MAUDE report 15973927 ↗
  • InjuryJun 1, 2021Loss of or Failure to Bond; Loss of or Failure to Bond

    ASEPTIC REVISION RIGHT KNEE. FEMUR AND TIBIAL TRAY WERE BOTH LOOSE, THE TIBIAL TRAY BEING LOOSER THAN THE FEMUR. THE LOOSENING WAS PRESENT AT BOTH INTERFACES (CEMENT TO BONE, CEMENT TO IMPLANT) FOR BOTH FEMUR AND TIBIAL TRAY PRODUCTS. THERE WAS NO REPORTED PRODUCT ISSUE WITH THE INSERT. THE PATELLA PRODUCT WAS RETAINED, NOT REVISED. NO INFORMATION AS TO THE ORIGINAL SURGERY WAS PROVIDED, AND NO INFORMATION REGARDING CEMENT MANUFACTURER.

    Patient problems: Insufficient Information

    MAUDE report 11913101 ↗
  • InjurySep 16, 2020Loss of or Failure to Bond; Loss of or Failure to Bond

    IT WAS REPORTED THAT REVISION OPERATIVE NOTES (B)(6) 2013 INDICATE THE PATIENT RECEIVED A RIGHT TOTAL KNEE REVISION DUE TO LOOSE AND PAINFUL RIGHT TOTAL KNEE. UPON ENTERING THE JOINT, METAL STAINED FLUID WAS ENCOUNTERED, SYNOVIUM SHOWED SEVERE METAL STAINING. SCAR TISSUE WAS DEBRIDED. THE TIBIAL INSERT WAS NOTED TO HAVE SLIGHT WEAR. THE TIBIAL AND FEMORAL COMPONENTS WERE STATED TO BE LOOSE, INTERFACE NOT PROVIDED. THE PATELLA WAS ALSO NOTED TO HAVE MINIMAL WEAR, IT WAS NOT REVISED. THE SURGERY WAS COMPLETED WITHOUT INDICATION OF COMPLICATION BY THE SURGEON. PRODUCTS IMPLANTED AT THIS REVISION ARE LOCATED ON PAGE 13-15. DOI: (B)(6) 2004 DOR: (B)(6) 2013 RIGHT KNEE.

    Patient problems: Adhesion(s); Foreign Body Reaction; No Code Available; Pain

    MAUDE report 10542289 ↗
  • MalfunctionAug 3, 2020Difficult to Open or Close; Difficult to Open or Close

    ADDITIONAL INFORMATION RECEIVED STATES THAT THE  IMPLANT WAS FIXED TO THE BOX. IT WAS STERILE BUT WHEN THEY OPEN THE BOX, THEY CANNOT EXTRACT IT.

    Patient problems: No Code Available; Not Applicable

    MAUDE report 10356581 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K241000, K950010, K952830, K971189. One submission often covers many models, so check the product and lot details in each record.

  • Z-2949-2018 · Jul 18, 2018 · Terminated
    P.F.C. SIGMA Revision Knee System Distal Augment, Model Number 960830
  • Z-0389-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 71 mm M/L, 47 mm A/P, 8.0 mm, 3, UHMWPE, sterile; Product Code/REF 96-0440.
  • Z-0390-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 71 mm M/L, 47 mm A/P, 10.0 mm, 3, UHMWPE, sterile; Product Code/REF 96-0441.
  • Z-0418-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized All-Polyethylene Tibia, 71mm M/L, 47mm A/P, 15.0mm, 3, UHMWPE, sterile; REF Product Code/96-2643.
  • Z-0391-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 71 mm M/L, 47 mm A/P, 12.5 mm, 3, UHMWPE, sterile; Product Code/REF 96-0442.
  • Z-0401-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System TC3 Tibial Insert, 5, 12.5mm, 83mm M/L, 55mm A/P, UHMWPE/Ti-6AI-4V, sterile; Product Code/REF 96-0551.
  • Z-0419-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized All-Polyethylene Tibia, 76mm M/L, 51mm A/P, 8.0mm, 4, UHMWPE, sterile; Product Code/REF 96-2650.
  • Z-0422-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Plus Tibial Insert (STAB PLUS), 64 mm M/L, 43 mm A/P, 17.5 mm, 2, UHMWPE, sterile; Product Code/REF 96-2713.
  • Z-0385-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 67 mm M/L, 45 mm A/P, 8.0 mm, 2.5, sterile; Product Code/REF 96-0430.
  • Z-0396-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System TC3 Tibial Insert, 2.5, 12.5mm, 67 mm M/L, 45 mm A/P, UHMWPE/Ti-6AI-4V, sterile; Product Code/REF 96-0521.
  • Z-0421-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Plus Tibial Insert (STAB PLUS), 64 mm M/L, 43 mm A/P, 15 mm, 2, UHMWPE, sterile; Product Code/REF 96-2712.
  • Z-0394-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee SystemStabilized Tibial Insert (STAB), 76 mm M/L, 51 mm A/P, 15.0 mm, 4, UHMWPE, sterile; Product Code/REF 96-0453.
  • Z-0395-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 89 mm M/L, 59 mm A/P, 10.0 mm, 6, UHMWPE, sterile; Product Code/REF 96-0471.
  • Z-0420-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized All-Polyethylene Tibia, 76mm M/L, 51mm A/P, 12.5mm, 4, UHMWPE, sterile; Product Code/REF 96-2652.
  • Z-0387-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 67 mm M/L, 45 mm A/P, 12.5 mm, 2.5, UHMWPE, sterile; Product Code/REF 96-0432.

…and 9 more.

Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page