P.F.C. SIGMA 96-0652Recalls & reported problems

Depuy (Ireland) · P.F.C. SIGMA TIBIAL COMPONENT ALL POLY CURVED 4 12.5mm CEMENTED · Class 2 · Implant

All models of P.F.C. SIGMA (487)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10603295233541), received between Apr 8, 2020 and Jul 18, 2022 — classified as 2 injuries.

The most frequently reported specific device problem is “Loss of or Failure to Bond” (2 reports).

31 other recalls cover devices cleared under the same FDA submission (K241000, K943462, K950010, K961685, K971189); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Loss of or Failure to Bond2

Patient problems

  • Insufficient Information1
  • No Code Available1
  • Pain1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 18, 2022Loss of or Failure to Bond; Loss of or Failure to Bond

    PATIENT WAS REVISED DUE TO LOOSENING OF THE TIBIA AND PATELLA AT THE CEMENT TO IMPLANT INTERFACE. CEMENT MANUFACTURER WAS UNKNOWN. THERE WAS NO SURGICAL DELAY. DOI: (B)(6) 2020. DOR: (B)(6) 2022. AFFECTED SIDE: RIGHT KNEE.

    Patient problems: Insufficient Information

    MAUDE report 15046880 ↗
  • InjuryApr 8, 2020Loss of or Failure to Bond; Loss of or Failure to Bond

    THE PATIENT WAS REVISED TO ADDRESS PAIN AND LOOSENING OF BOTH RIGHT AND LEFT KNEE TIBIAL COMPONENTS AT THE BONE TO CEMENT AND CEMENT TO IMPLANT INTERFACES. DEPUY CEMENT WAS USED. SURGEON WHO PERFORMED PRIMARY TOTAL KNEES USED DEPUY MV CEMENT, WHICH WAS HOSPITAL OWNED INVENTORY SO NO INFORMATION IS AVAILABLE. BOTH ALL POLY TIBIAS HAD CEMENT ON THE BASE OF THE TRAY, BUT NO ADHERENCE TO THE KEEL. BOTH TIBIAS HAD WELL FIXED MANTLES AT THE KEEL BUT NO MANTLE AT THE PLATEAU. BOTH FEMURS AND PATELLA WERE VERY WELL FIXED. DOI: (B)(6) 2018; DOR: (B)(6) 2020; LEFT KNEE.

    Patient problems: No Code Available; Pain

    MAUDE report 9938677 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K241000, K943462, K950010, K961685, K971189. One submission often covers many models, so check the product and lot details in each record.

  • Z-1077-2014 · Dec 9, 2013 · Terminated
    PFC SIGMA Cruciate Retaining (CR); Cemented Femoral devices; (Size 5/RT) Used during primary total knee arthroplasty to improve patient mobility.
  • Z-1686-2009 · May 7, 2009 · Terminated
    DePuy P.F.C. Sigma Knee System, Non-Porous Cruciate Retaining Femoral Component, 73 mm M/L 69 mm A/P, 5 left, sterile, DePuy Orthopaedics, Inc., Warsaw, IN; REF 96-0005. The devic
  • Z-0403-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System All Polyethylene Curved Tibial Component, 3, 8 mm, 71mm M/L, 47 mm A/P, UHMWPE, sterile; Product Code/ REF 96-0640.
  • Z-0422-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Plus Tibial Insert (STAB PLUS), 64 mm M/L, 43 mm A/P, 17.5 mm, 2, UHMWPE, sterile; Product Code/REF 96-2713.
  • Z-0389-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 71 mm M/L, 47 mm A/P, 8.0 mm, 3, UHMWPE, sterile; Product Code/REF 96-0440.
  • Z-0395-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 89 mm M/L, 59 mm A/P, 10.0 mm, 6, UHMWPE, sterile; Product Code/REF 96-0471.
  • Z-0402-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System All Polyethylene Curved Tibial Component, 2.5, 8 mm, 67mm M/L, 45 mm A/P, UHMWPE, 2.5, sterile; Product Code/REF 96-0630.
  • Z-0407-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System All Polyethylene Curved Tibial Component, 5, 15mm, 83mm M/L, 55mm A/P, UHMWPE, sterile; Product Code/REF 96-0663.
  • Z-0391-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 71 mm M/L, 47 mm A/P, 12.5 mm, 3, UHMWPE, sterile; Product Code/REF 96-0442.
  • Z-0420-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized All-Polyethylene Tibia, 76mm M/L, 51mm A/P, 12.5mm, 4, UHMWPE, sterile; Product Code/REF 96-2652.
  • Z-0393-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 76 mm M/L, 51 mm A/P, 12.5 mm, 4, UHMWPE, sterile; Product Code/REF 96-0452.
  • Z-0385-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Tibial Insert (STAB), 67 mm M/L, 45 mm A/P, 8.0 mm, 2.5, sterile; Product Code/REF 96-0430.
  • Z-0419-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized All-Polyethylene Tibia, 76mm M/L, 51mm A/P, 8.0mm, 4, UHMWPE, sterile; Product Code/REF 96-2650.
  • Z-0418-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized All-Polyethylene Tibia, 71mm M/L, 47mm A/P, 15.0mm, 3, UHMWPE, sterile; REF Product Code/96-2643.
  • Z-0421-2008 · Sep 27, 2007 · Terminated
    Depuy P.F.C. E Knee System Stabilized Plus Tibial Insert (STAB PLUS), 64 mm M/L, 43 mm A/P, 15 mm, 2, UHMWPE, sterile; Product Code/REF 96-2712.

…and 16 more.

Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices →

Sources and updates