Skip to content

SIGMA 97-2340Recalls & reported problems

Depuy (Ireland) · SIGMA CURVED PLUS INSERT TRIAL SIZE 2.5 8mm · Class 1

All models of SIGMA (380)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10603295251033), received between Jun 1, 2022 and Jul 13, 2023 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Break2
  • Scratched Material1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 13, 2023Break; Scratched Material; Break; Scratched Material

    IT WAS REPORTED THAT THE POLY TRIAL WAS SCRATCHED AND CHIPPED. IT DID NOT HAPPEN IN SURGERY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17315001 ↗
  • MalfunctionJun 1, 2022Break; Break

    TRIAL IS WORN. SMALL PIECE WAS CRACKED ON UNDERSIDE AND NOTICED WHILE WASHING IN SPD. ALL PIECES WERE RECOVERED. NO SURGICAL DELAY. NO ADVERSE AFFECTS ON THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14565681 ↗

Other TEMPLATE devices

All TEMPLATE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page