GLOBAL ICON 1140-20-048Recalls & reported problems
Depuy (Ireland) · GLOBAL ICON STEMLESS SHOULDER SYSTEM HUMERAL HEAD DIAMETER 48mm · Class 2 · Implant
All models of GLOBAL ICON (20)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10603295381259), received between Jan 29, 2020 and Mar 7, 2024 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- No Code Available1
- Unspecified Musculoskeletal problem1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMar 7, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
SUBJECT ID: (B)(6). STUDY NO: (B)(4). CLINICAL ADVERSE EVENT RECEIVED FOR REMOVAL OF OSTEOPHYTES AND SUBSCAPULARIS REPAIR. EVENT IS SERIOUS AND IS CONSIDERED MODERATE. EVENT IS POSSIBLY RELATED TO BOTH DEVICE AND PROCEDURE. DATE OF IMPLANT: (B)(6) 2019; DATE OF EVENT: (B)(6) 2023, (RIGHT SHOULDER). TREATMENT: REMOVAL OF OSTEOPHYTES AND SUBSCAPULARIS REPAIR.
Patient problems: Unspecified Musculoskeletal problem
MAUDE report 18857862 ↗InjuryJan 29, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
CLINICAL ADVERSE EVENT RECEIVED FOR BURSITIS. EVENT IS NOT SERIOUS AND IS CONSIDERED MILD. EVENT IS PROBABLY RELATED TO BOTH DEVICE AND PROCEDURE. DATE OF IMPLANTATION: (B)(6) 2018; DATE OF EVENT (ONSET): (B)(6) 2020; (RIGHT SHOULDER).
Patient problems: No Code Available
MAUDE report 9641659 ↗
Other Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained devices
- Tornier Perform DWM003ATornier, Inc. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained1 recall1 report
- Sidus® Stem-Free Shoulder 01.04555.500Zimmer GmbH · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained1 recall1 report
- DJO SURGICAL 520-08-021Encore Medical, L.P. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained20 reports
- INHANCE 5200-00-036Depuy (Ireland) · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained17 reports
- Easytech Anatomical Shoulder System 314-0038Fx Solutions · Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained14 reports
- Tornier Simpliciti® Shoulder System 7122872Tornier, Inc. · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained9 reports
- Sidus® Stem-Free Shoulder 01.04555.110Zimmer GmbH · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained6 reports
- GLOBAL ICON 1140-10-054Depuy (Ireland) · Prosthesis, total anatomic shoulder, uncemented metaphyseal humeral stem with no diaphyseal incursion, semi-constrained6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page