Skip to content

ATTUNE 2545-06-002Recalls & reported problems

Depuy (Ireland) · ATTUNE KNEE SYSTEM FEMORAL TENSOR POST RIGHT · Class 1

All models of ATTUNE (1475)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10603295496960), received between Oct 29, 2021 and Sep 26, 2024 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Mechanical Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Mechanical Problem2
  • Unintended Movement2
  • Device-Device Incompatibility1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 26, 2024Device-Device Incompatibility; Device-Device Incompatibility

    INTRAOPERATIVELY IT WAS NOTICED THAT THE TWO INSTRUMENTS BELONGING TOGETHER CANNOT BE CONNECTED/ASSEMBLED. NO PATIENT HARM REPORTED, NO SURGICAL DELAY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20310295 ↗
  • MalfunctionOct 29, 2021Mechanical Problem; Unintended Movement; Mechanical Problem; Unintended Movement

    COMPLAINT LINK TO THE COMPLAINT (B)(4): SECOND COMPLAINT OPEN REGARDING THE INCIDENT OCCURRED ON "A FEW WEEKS AGO" : "END OF AFTERNOON, THE SURGEON HAD ISSUE TO DISTRACT THE KNEE WITH THE THEMIS. THE INSTRUMENT WAS INTRODUCED IN EXTENSION, THE SURGEON WAS SUPPORTING THE BACK OF THE KNEE BUT WHEN HE WAS QUIZZING THE HANDLE TO DISTRACT THE SPRING WAS COMPRESSING (UP TO MAXIMUM) BUT THE TENSER WAS NOT APPLYING ANY TENSION ON THE ARTICULATION (HE WAS NOT MOVING); THE TENSER HAD SPACE IN THE ARTICULATION, IT WAS MOVING A BIT BUT WAS NOT DISTRACTING. OUT SIDE THE KNEE THE TENSER WAS DISTRACTING WHEN SQUEEZING THE HANDLE BUT IT WAS A BIT DIFFICULT TO BRING IT BACK TO 0 AND WHEN THE SALES REP WAS MOUNTING IT SHE FILLED DIFFICULT TO PUT THE FEMORAL PART IN THE TIBIAL PART. THIS PROBLEM HAPPENED ALREADY ONCE A FEW WEEK AGO WITH THE SAME PROBLEM. BUT THEY WERE NOT THINKING OF ISSUE WITH THE THEMIS. THE SALES REP COME ON 18 OCT 2021 TO SEE WHAT WAS HAPPENING. IT WAS A RIGHT KNEE. NO ADDITIONAL TIME OF THE SURGERY AND NO NEGATIVE EFFECT FOR THE PATIENT THE SURGEON USED THE SPACER BOCK TO CHECK THE SPACES. THE THEMIS IS ON CONSIGNMENT, IT WILL BE SENT BACK TO SAINT PRIEST FOR INVESTIGATION. (B)(

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12721712 ↗
  • MalfunctionOct 29, 2021Mechanical Problem; Unintended Movement; Mechanical Problem; Unintended Movement

    END OF AFTERNOON, THE SURGEON HAD ISSUE TO DISTRACT THE KNEE WITH THE THEMIS. THE INSTRUMENT WAS INTRODUCED IN EXTENSION, THE SURGEON WAS SUPPORTING THE BACK OF THE KNEE BUT WHEN HE WAS QUIZZING THE HANDLE TO DISTRACT THE SPRING WAS COMPRESSING (UP TO MAXIMUM) BUT THE TENSER WAS NOT APPLYING ANY TENSION ON THE ARTICULATION (HE WAS NOT MOVING); THE TENSER HAD SPACE IN THE ARTICULATION, IT WAS MOVING A BIT BUT WAS NOT DISTRACTING. OUT SIDE THE KNEE THE TENSER WAS DISTRACTING WHEN SQUEEZING THE HANDLE BUT IT WAS A BIT DIFFICULT TO BRING IT BACK TO 0 AND WHEN THE SALES REP WAS MOUNTING IT SHE FILLED DIFFICULT TO PUT THE FEMORAL PART IN THE TIBIAL PART. THIS PROBLEM HAPPENED ALREADY ONCE A FEW WEEK AGO WITH THE SAME PROBLEM. BUT THEY WERE NOT THINKING OF ISSUE WITH THE THEMIS (SEE COMPLAINT (B)(4)). THE SALES REP COME ON (B)(6) 2021 TO SEE WHAT WAS HAPPENING. IT WAS A RIGHT KNEE. NO ADDITIONAL TIME OF THE SURGERY AND NO NEGATIVE EFFECT FOR THE PATIENT THE SURGEON USED THE SPACER BOCK TO CHECK THE SPACES. THE THEMIS IS ON CONSIGNMENT, IT WILL BE SENT BACK TO SAINT PRIEST FOR INVESTIGATION. (B)(6) 2021 THE SURGEON DID A SECOND KNEE WITH THEMIS AND IT WORKS WELL.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12721578 ↗

Other TEMPLATE devices

All TEMPLATE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page