Skip to content

EMPHASYS 4722-54-240Recalls & reported problems

Depuy Orthopaedics, Inc. · EMPHASYS POLYETHYLENE LINER AOX ELEVATED RIM 54MM 40MM · Class 2 · Implant

All models of EMPHASYS (34)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10603295500230), received between Aug 5, 2026 and Sep 29, 2026 — classified as 3 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 2 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated2
  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Joint Dislocation2
  • Unspecified Infection1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjurySep 29, 2026Device Dislodged or Dislocated

    It was reported that Due to dislocation, Dr. removed head, cup and liner and replaced with competitor cup and liner and new Depuy headDOI(B)(6) 2026DOR (B)(6) 2026Affected side-Left

    Patient problems: Joint Dislocation

    MAUDE report 50931181 ↗
  • InjuryAug 17, 2026Device Dislodged or Dislocated

    It was reported that the patient was dislocated. Cup, head and liner were explanted and replaced with a larger DM construct.DOI: (b)(6) 2025.DOR: (b)(6) 2026.Affected side: Right hip.

    Patient problems: Joint Dislocation

    MAUDE report 50283774 ↗
  • InjuryAug 5, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that washout and head and liner exchange for infection.Affected Side: Right Hip.

    Patient problems: Unspecified Infection

    MAUDE report 50140920 ↗

Other Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices

All Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page