Skip to content

INHANCE 6105-10-040Recalls & reported problems

Depuy (Ireland) · INHANCE SHOULDER SYSTEM GLENOID SIZER MEDIUM · Class 1

All models of INHANCE (202)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 10603295538837), received between Aug 3, 2022 and Jul 8, 2026 — classified as 11 malfunctions.

The most frequently reported specific device problem is “Crack” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 3 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Crack6
  • Break5
  • No Apparent Adverse Event1

Patient problems

  • No Clinical Signs, Symptoms or Conditions8
  • Insufficient Information3

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 8, 2026Crack

    IT WAS REPORTED THAT THE TIP OF THE STEM INSERTER WAS BROKEN, AND THE MEDIUM GLENOID SIZER WAS CRACKED DUE TO GENERAL WEAR AND TEAR.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25753519 ↗
  • MalfunctionNov 26, 2025Crack; Crack

    IT WAS REPORTED THAT WHEN EXTRACTING THE HUMERAL STEM PIN PUNCH, ONE OF THE PINS BROKE OFF. IT WAS RETRIEVED AND THE MEDIUM GLENOID SIZER CRACKED WHILE PUTTING IT ON THE SIZER HANDLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23658919 ↗
  • MalfunctionMar 13, 2025Break; Crack; Break; Crack

    IT WAS REPORTED THAT BOTH THE SMALL AND MEDIUM GLENOID SIZERS WERE CRACKED WHEN PUTTING INSTRUMENTS BACK TOGETHER AFTER CASE. THESE NEEDS TO BE REPLACED. ALL BROKEN PARTS WERE RETRIEVED AND NO SURGICAL DELAYS TOOK PLACE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21597709 ↗
  • MalfunctionAug 27, 2024Break; Break

    IT WAS REPORTED THAT THE MEASURING INSTRUMENTS WERE BROKEN.

    Patient problems: Insufficient Information

    MAUDE report 20075641 ↗
  • MalfunctionAug 27, 2024Break; Break

    IT WAS REPORTED THAT THE MEASURING INSTRUMENTS WERE BROKEN.

    Patient problems: Insufficient Information

    MAUDE report 20075631 ↗
  • MalfunctionAug 27, 2024Break; Break

    IT WAS REPORTED THAT THE MEASURING INSTRUMENTS WERE BROKEN.

    Patient problems: Insufficient Information

    MAUDE report 20075614 ↗
  • MalfunctionMar 18, 2024Crack; Crack

    IT WAS REPORTED THAT THE SIZER HAS CRACKED. WAS SURGERY DELAYED DUE TO THE REPORTED EVENT? UNKNOWN. WAS PROCEDURE SUCCESSFULLY COMPLETED? UNKNOWN. WERE FRAGMENTS GENERATED? UNKNOWN, IF YES, WERE THEY REMOVED EASILY WITHOUT ADDITIONAL INTERVENTION? UNKNOWN. PATIENT STATUS/ OUTCOME / CONSEQUENCES ? NO. WAS OTHER MEDICAL INTERVENTION (E.G. X-RAYS, ADDITIONAL PROCEDURES, PRESCRIPTIONS, OTC, REVISION) REQUIRED: UNKNOWN. IS THE PATIENT PART OF A CLINICAL STUDY? UNKNOWN. (B)(4). DEVICE PROPERTY OF ? NONE. DEVICE IN POSSESSION OF ? NONE. BY CHECKING THIS BOX I CERTIFY THAT ALL INFORMATION THAT ARE KNOWN/AVAILABLE HAS BEEN DISCLOSED. IF ANY NEW INFORMATION WILL BE MADE AVAILABLE, THE ADDITIONAL INFORMATION WILL BE SUBMITTED THROUGH CST.? TRUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18922264 ↗
  • MalfunctionFeb 5, 2024Crack; Crack

    IT WAS REPORTED THAT MEDIUM HUMERAL SIZER CRACKED WHILE SIZING. SURGICAL DELAY WAS UNKNOWN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18640855 ↗
  • MalfunctionOct 13, 2023Crack; Crack

    IT WAS REPORTED THAT BOTH THE OFFSET ADAPTER AND MEDIUM GLENOID SIZE HAVE CRACKS IN THEM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17929713 ↗
  • MalfunctionMay 18, 2023Break; Break

    IT WAS REPORTED THAT SIZER BROKE DURING SURGERY, WHILE BEING USED. ALL PIECES WERE RETRIEVED. SURGICAL DELAY UNKNOWN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16952146 ↗
  • MalfunctionAug 3, 2022No Apparent Adverse Event; No Apparent Adverse Event

    IT WAS REPORTED THAT THE INHANCE GLENOID SIZERS GET LOST AT A RATE THAT FAR EXCEEDS NORMAL INSTRUMENTATION. THE SURGEON NEEDED THE SIZERS FOR THEIR CASES BUT ITS DIFFICULT WHEN THESE SIZERS ARE CONSTANTLY MISSING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15158103 ↗

Other TEMPLATE devices

All TEMPLATE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page