Skip to content

Deltec 21-4182-24Recalls & reported problems

Icu Medical, Inc. · Class 2 · Implant

All models of Deltec (97)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
0
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

No MAUDE adverse event reports in our data reference this device identifier directly.

1 FDA recall record name this device's identifier, 1 still open.

11 other recalls cover devices cleared under the same FDA submission (K994216); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Feb 13, 2025Class IOpen, Classified

    The plastic port housing and port reservoir of the ProPort Plastic Implantable Ports may separate because of a manufacturing defect.

    Z-1286-2025 · Root cause: Process control · Recall details · FDA record ↗

FDA clearance and classification

Cleared through 510(k) K994216 on Jan 27, 2000 (decision: Substantially Equivalent). Submitted by Sims Deltec, Inc. as “Plastic Port Implantable Venous Access System”. The FDA review took 43 days. FDA record ↗

The FDA regulates product code LJT (port & catheter, implanted, subcutaneous, intravascular) under 21 CFR 880.5965 as a Class II device. 21 CFR 880.5965 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K994216. One submission often covers many models, so check the product and lot details in each record.

  • Z-1280-2025 · Feb 13, 2025 · Open, Classified
    smiths medical ProPort Plastic Venous Access System, PolyFlow Polyurethane Catheter, 1.9mm (5.8Fr) O.D. x 1.0mm I.D., 6Fr Introducer, REF 21-4153-24
  • Z-1287-2025 · Feb 13, 2025 · Open, Classified
    smiths medical ProPort Low Profile Plastic Venous Access System, PolyFlow Polyurethane Catheter, 1.9mm (5.8Fr) O.D. x 1.0mm., 6Fr Introducer, REF 21-4183-24
  • Z-1283-2025 · Feb 13, 2025 · Open, Classified
    smiths medical ProPort Plastic Venous Access System, PolyFlow Catheter, 2.6 (7.8Fr) O.D. x 1.6mm I.D., 8.5Fr Introducer, REF 21-4171-24
  • Z-1288-2025 · Feb 13, 2025 · Open, Classified
    smiths medical ProPort Low Profile Plastic Venous Access System, Silicone Catheter, 2.8mm (8.4Fr) O.D. x 1.0mm I.D., 9Fr Introducer, REF 21-4187-24
  • Z-1282-2025 · Feb 13, 2025 · Open, Classified
    smiths medical ProPort Plastic Venous Access System, Pre-assembled with PolyFlow Polyurethane Catheter, 2.6mm (7.8Fr) O.D. x 1.6mm I.D., 8.6Fr Introducer, REF 21-4165-24
  • Z-1281-2025 · Feb 13, 2025 · Open, Classified
    smiths medical ProPort Plastic Venous Access System, PolyFlow Polyurethane Catheter, 2.6mm O.D. (7.8Fr) x 1.6mm I.D., REF 21-4155-24
  • Z-0871-04 · Mar 29, 2004 · Terminated
    ProPort Plastic Venous Access System, with PolyFlow Polyurethane Catheter, 2.6mm O.D. x 1.6mm I.D., 8.5 French Introducer Set, REF 21-4155-24
  • Z-0875-04 · Mar 29, 2004 · Terminated
    Port-A-Cath P.A.S. Port T2 Titanium Venous Access System, with PolyFlow Polyurethane Catheter, 1.9mm O.D. x 1.0mm I.D., 6 French Introducer Set, REF 21-4573-24
  • Z-0873-04 · Mar 29, 2004 · Terminated
    ProPort Low Profile Plastic Venous Access System, with PolyFlow Polyurethane Catheter, 2.6mm O.D. x 1.6mm I.D., 8.5 French Introducer Set, REF 21-4171-24
  • Z-0874-04 · Mar 29, 2004 · Terminated
    ProPort Low Profile Plastic Venous Access System, with PolyFlow Polyurethane Catheter, 1.9mm O.D. x 1.0mm I.D., 6 French Introducer Set, REF 21-4183-24
  • Z-0872-04 · Mar 29, 2004 · Terminated
    ProPort Plastic Venous Access System, Pre-assembled with PolyFlow Polyurethane Catheter, 2.6mm O.D. x 1.6mm I.D., 8.5 French Introducer Set, REF 21-4165-24

Common questions about the Deltec 21-4182-24

Has the Deltec 21-4182-24 been recalled?

Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-1286-2025 (Class I), began on Feb 13, 2025: The plastic port housing and port reservoir of the ProPort Plastic Implantable Ports may separate because of a manufacturing defect. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

Is the Deltec 21-4182-24 FDA approved?

It was cleared through 510(k) K994216 on Jan 27, 2000. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the Deltec 21-4182-24 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.

Who makes the Deltec 21-4182-24, and is it still sold?

The FDA's device database lists Icu Medical, Inc. as the company responsible for it (brand Deltec, model 21-4182-24). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR devices

All PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR devices →

Sources and updates