Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10610586023521), received between Nov 5, 2024 and Dec 12, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Air/Gas in Device” (2 reports).
1 other recall cover devices cleared under the same FDA submission (K830730); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Air/Gas in Device2
- Crack1
- Material Split, Cut or Torn1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 12, 2024Crack; Air/Gas in Device; Crack; Air/Gas in Device
IT WAS REPORTED THAT THE IRRIGATION CANNULA WAS CONNECTED TO THE CATHETER, AND WHEN ASPIRATION OCCURRED, AIR CAME BACK INSTEAD OF LIQUID. THEY NOTICED THAT THE END OF THE CATHETER WAS CRACKED. THE DEVICE WAS OPERATED BY THE PHYSICIAN. THE EVENT OCCURRED INTRAOPERATIVELY; THERE WAS PATIENT INVOLVEMENT, AND NO PATIENT HARM/ADVERSE EVENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20915341 ↗MalfunctionNov 5, 2024Material Split, Cut or Torn; Air/Gas in Device; Material Split, Cut or Torn; Air/Gas in Device
IT WAS REPORTED THAT WHEN THE CATHETER WAS INSERTED AND ASPIRATION WAS ATTEMPTED, AIR RESURFACED INSTEAD OF BLOOD. IT WAS NOTICED THAT THE COATING OF THE CATHETER WAS TORN. A NEW CATHETER WAS USED AND THERE WERE NO NEGATIVE CONSEQUENCES FOR THE PATIENT. THE EVENT OCCURRED IN THE HOSPITAL, WHILE IN USE WITH THE PATIENT. THE OPERATOR OF THE DEVICE WAS A HEALTHCARE PROFESSIONAL. THERE WAS PATIENT INVOLVEMENT, AND NO PATIENT HARM/ADVERSE EVENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20613318 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K830730. One submission often covers many models, so check the product and lot details in each record.
- Z-0152-2016 · Sep 14, 2015 · TerminatedPORT-A-CATH Plastic Hub Needles, 0.9mm (20G) x 19mm (3/4 in.) 90-degree. REF 21-2287-24 The Plastic hub PORT-A-CATH (PAC) needles are intended to access the implantable portal sy
Other PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR devices
- PowerPort M.R.I., Groshong 9808560Bard Access Systems, Inc. · PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR3 deaths834 reports
- PowerPort ClearVUE 1608062Bard Access Systems, Inc. · PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR18 deaths571 reports
- PowerPort ClearVUE 5608062Bard Access Systems, Inc. · PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR31 deaths542 reports
- PowerPort M.R.I., ChronoFlex 1808000Bard Access Systems, Inc. · PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR19 deaths513 reports
- PowerPort M.R.I., ChronoFlex 1808060Bard Access Systems, Inc. · PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR1 recall15 deaths383 reports
- PowerPort M.R.I., Groshong 1808560Bard Access Systems, Inc. · PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR10 deaths304 reports
- PowerPort M.R.I., ChronoFlex 1829500Bard Access Systems, Inc. · PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR6 deaths197 reports
- BardPort M.R.I. 0602680Bard Access Systems, Inc. · PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR2 deaths179 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page