Halyard 13672Recalls & reported problems
Avanos Medical, Inc. · HALYARD* ON-Q* Pump Fixed Flow-270 ml-4 ml/hr (dual; 2 ml/site) · Class 2
All models of Halyard (232)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10680651136722), received between Mar 15, 2017 and Mar 4, 2019 — classified as 1 injury, 3 malfunctions.
The most frequently reported specific device problem is “Infusion or Flow Problem” (3 reports).
3 other recalls cover devices cleared under the same FDA submission (K063530); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Infusion or Flow Problem3
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- No Known Impact Or Consequence To Patient3
- Seizures1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 4, 2019Infusion or Flow Problem; Infusion or Flow Problem
AVANOS MEDICAL, INC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING TWO DIFFERENT EVENTS. THIS IS THE SECOND OF TWO REPORTS. REFER TO 2026095-2019-00034 FOR THE FIRST EVENT. FILL VOLUME: 270 ML, FLOW RATE: 4 ML/HR, PROCEDURE: UNKNOWN, CATHPLACE: UNKNOWN, START DATE/TIME: (B)(6) 2019 AT 1255, STOP DATE/TIME: (B)(6) 2019 AT 0200. IT WAS REPORTED THE ON-Q DEVICE RAN OUT SOONER THAN EXPECTED. THERE WAS NO REPORTED PATIENT INJURY. ADDITIONAL INFORMATION RECEIVED (B)(6) 2019 STATED THE REPORTING PHARMACIST CALLED TO NOTIFY THAT THE SAMPLE WAS DISCARDED AND NOT AVAILABLE TO RETURN ANYMORE. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8388570 ↗MalfunctionMar 2, 2019Infusion or Flow Problem; Infusion or Flow Problem
AVANOS MEDICAL, INC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING TWO DIFFERENT EVENTS. THIS IS THE FIRST OF TWO REPORTS. REFER TO 2026095-2019-00035 FOR THE SECOND EVENT. FILL VOLUME: 270 ML, FLOW RATE: 4 ML/HR, PROCEDURE: UNKNOWN, CATHPLACE: UNKNOWN, START DATE/TIME: (B)(6) 2019 AT 0800, STOP DATE/TIME: (B)(6) 2019 AT 2054. IT WAS REPORTED THE ON-Q DEVICE RAN OUT IN LESS THAN 40-HOURS, ACCORDING TO PHARMACY THE DEVICE SHOULD OF LASTED 67-HOURS. UPON ASSESSMENT, THERE WAS NO LEAK FOUND AT THE INSERTION SITE. ADDITIONAL INFORMATION RECEIVED (B)(6) 2019 STATED THE REPORTING PHARMACIST CALLED TO NOTIFY THAT THE SAMPLE WAS DISCARDED AND NOT AVAILABLE TO RETURN ANYMORE. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8384680 ↗MalfunctionJan 17, 2019Infusion or Flow Problem; Infusion or Flow Problem
FILL VOLUME: 270 ML. FLOW RATE: UNKNOWN. PROCEDURE: ABDOMINOPLASTY. CATHPLACE: UNKNOWN. DATE/TIME INFUSION START: (B)(6) 2019 AT 1:00PM, DATE/TIME INFUSION STOP: 48-HOURS AFTER SURGERY (B)(6) 2019. IT WAS REPORTED A FAST FLOW EVENT OCCURRED. ADDITIONAL INFORMATION RECEIVED (B)(6) 2019 STATED THE OPERATING ROOM (OR) NURSE "CUT OFF THE WHITE CLIPS AND DISPOSED OF THE PUMP". THE PATIENT REPORTED THAT THE DEVICE INFUSED IN 48-HOURS. ADDITIONAL INFORMATION RECEIVED (B)(6) 2019 STATED THE DEVICE WAS CARRIED IN ON-Q BAG SECURED THE AROUND PATIENT'S WAIST. ADDITIONAL INFORMATION RECEIVED (B)(6) 2019 STATED THE PUMP WAS FILLED "THE BEFORE OR THE MORNING OF THE SAME DAY OF USE". THERE WAS NO REPORTED INJURY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8259314 ↗InjuryMar 15, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
FILL VOLUME: 125 ML, FLOW RATE: 4 ML/HR, PROCEDURE: RIB PLATING, CATHPLACE: UNKNOWN, PUMP START TIME: (B)(6) 2017 UNKNOWN TIME, PUMP STOP TIME: (B)(6) 2017 5:36 PM. IT WAS REPORTED THAT A INTENSIVE CARE UNIT PATIENT EXPERIENCED A SEIZURE IN THE EARLY MORNING 12-HOURS AFTER USING THE ELASTOMERIC PUMP, WHICH FOLLOWED HER RIB PLATING PROCEDURE. THE PUMP WAS PLACED ON (B)(6) 2017, AND WAS NOT LABELED WITH WHAT MEDICATION WAS IN THE PUMP. THE PUMP WAS PULLED ON THE NIGHT OF (B)(6) 2017 AND WAS DISCARDED. IT WAS UNKNOWN IF THE PATIENT EXPERIENCED ANYMORE SEIZURES, AND THERE WAS NO FURTHER REPORT ON THE PATIENT'S STATUS. ADDITIONAL INFORMATION RECEIVED ON 28-FEB-2017 STATED THAT AN INTERNAL INVESTIGATION WAS PERFORMED AND IT WAS DISCOVERED THAT THE SEIZURE WAS NOT RELATED TO THE USE OF THE PUMP. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: Seizures
MAUDE report 6407611 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K063530. One submission often covers many models, so check the product and lot details in each record.
- Z-2860-2011 · Apr 15, 2011 · TerminatedI-Flow ON-Q with Select-A-Flow Pumps, Intended for continuous and/or intermittent delivery of medication to and around surgical wound sites and/or close proximity to nerves for p
- Z-2133-2008 · Feb 14, 2008 · TerminatedOn-Q C-bloc 400 ml, 1-7 ml/hr Select-A-Flow + 5 ml/60 min ONDEMAND, REF CB005 indicated for continuous and/or intermittent delivery of medication (such as local anesthetics or narc
- Z-1869-2008 · Feb 12, 2008 · TerminatedON-Q PainBuster Infusion Pump (270 ml, 5 ml/hr), REF PS6504, Part No. 5001260. The pump is indicated for continuous and/or intermittent delivery of medication (such as local anest
Other PUMP, INFUSION, ELASTOMERIC devices
- EASYPUMP 4540018-02B. Braun Medical Inc. · PUMP, INFUSION, ELASTOMERIC313 reports
- Halyard 13568Avanos Medical, Inc. · PUMP, INFUSION, ELASTOMERIC86 reports
- ON-Q* Pain Relief System with SELECT-A-FLOW 13472Avanos Medical, Inc. · Pump, infusion, elastomeric73 reports
- Halyard 13472Avanos Medical, Inc. · PUMP, INFUSION, ELASTOMERIC68 reports
- EASYPUMP 4540008-02B. Braun Medical Inc. · PUMP, INFUSION, ELASTOMERIC54 reports
- DOSI-FUSER L25915-500D1-USALeventon Sau · Pump, Infusion, Elastomeric1 recall0 reports
- DOSI-FUSER L25915-600D1-USALeventon Sau · Pump, Infusion, Elastomeric1 recall0 reports
- Halyard 13561Avanos Medical, Inc. · PUMP, INFUSION, ELASTOMERIC42 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page