Summary
The FDA's MAUDE database contains 20 adverse event reports that list this exact device (DI 10705031008106), received between Mar 25, 2019 and Feb 21, 2025 — classified as 20 malfunctions.
The most frequently reported specific device problem is “Delivered as Unsterile Product” (12 reports).
8 other recalls cover devices cleared under the same FDA submission (K946173); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Delivered as Unsterile Product12
- Packaging Problem12
- Break7
- Device Contaminated During Manufacture or Shipping1
Patient problems
- No Clinical Signs, Symptoms or Conditions16
- No Consequences Or Impact To Patient4
Recent adverse event reports
The 20 most recent of 20 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 21, 2025Break; Break
IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON (B)(6) 2024 AND SUTURE WAS USED. DURING THE PROCEDURE, PER USER FACILITY MEDWATCH FORM #MW5164421, THE 0 SILK ON FSL (FOR SKIN LARGE) NEEDLE BEING USED TO SECURE CHEST TUBE. SMALL TIP OF NEEDLE BROKE OFF AND WAS NOT FOUND. X-RAY DONE BEFORE PRIOR TO LEAVING THE OR (OPERATING ROOM). DEVICE IS AVAILABLE FOR RETURN. THERE WERE NO ADVERSE CONSEQUENCES REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21432406 ↗MalfunctionJun 21, 2024Device Contaminated During Manufacture or Shipping; Device Contaminated During Manufacture or Shipping
IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON AN UNKNOWN DATE AND SUTURE WAS USED. IT FOUND THAT THERE HAD BEEN A ONE FOREIGN MATTER IN THE STERILIZATION PACKAGE BY AN INSPECTION IN THE TESTING SECTION OF THE PLANT. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19588318 ↗MalfunctionNov 20, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18174547 ↗MalfunctionNov 20, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18174446 ↗MalfunctionNov 20, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18174443 ↗MalfunctionNov 20, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18174419 ↗MalfunctionNov 20, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18174399 ↗MalfunctionNov 20, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18174390 ↗MalfunctionOct 13, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17931287 ↗MalfunctionOct 13, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17931285 ↗MalfunctionOct 13, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17931284 ↗MalfunctionOct 13, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17931276 ↗MalfunctionOct 13, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17931268 ↗MalfunctionOct 13, 2023Delivered as Unsterile Product; Packaging Problem; Delivered as Unsterile Product; Packaging Problem
IT WAS REPORTED THAT THE CUSTOMER RECEIVED A THREAD PACK WITH RED MARKED AND OPENED THREADS. THE PACKAGING BLISTER HAS THE RED MARKING AND THESE BLISTERS ARE ALSO OPEN. THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17931244 ↗MalfunctionOct 13, 2023Break; Break
IT WAS REPORTED THAT A PATIENT UNDERWENT A CHOLECYSTECTOMY ON (B)(6) 2023 AND SUTURE WAS USED. DURING THE PROCEDURE, WHILE SUTURING UNKNOWN TISSUE, WHEN THE DOCTOR PULLED THE SUTURE THROUGH THE TISSUE, THE SUTURE BROKE. ANOTHER LIKE DEVICE WAS USED TO CONTINUE WITH THE PROCEDURE. THERE WERE NO ADVERSE CONSEQUENCES FOR THE PATIENT. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17929825 ↗MalfunctionMar 20, 2022Break; Break
IT WAS REPORTED THAT A PATIENT UNDERWENT AN CABG PROCEDURE ON (B)(6) 2022 AND SUTURE WAS USED. THE SUTURE BROKE WHILE NOT PUTTING MUCH PRESSURE ON IT. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13828362 ↗MalfunctionOct 16, 2020Break; Break
IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON (B)(6) 2020, AND SUTURE WAS USED. DURING THE PROCEDURE, THE TIP OF THE NEEDLE BROKE. THE TIP OF NEEDLE WAS RETRIEVED BY THE PHYSICIAN. THE DEVICE IS NOT AVAILABLE FOR RETURN. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10692279 ↗MalfunctionMar 25, 2019Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A VATS PROCEDURE ON (B)(6) 2019 AND SUTURE WAS USED. WHILE THE DOCTOR WAS KNOTTING THE SUTURE, IT WAS BROKEN. ANOTHER SUTURE WAS USED TO COMPLETE THE PROCEDURE. NO ADVERSE PATIENT OUTCOME WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8450537 ↗MalfunctionMar 25, 2019Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A VATS PROCEDURE ON (B)(6) 2019 AND SUTURE WAS USED. WHILE THE DOCTOR WAS KNOTTING THE SUTURE, IT WAS BROKEN. ANOTHER SUTURE WAS USED TO COMPLETE THE PROCEDURE. NO ADVERSE PATIENT OUTCOME WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8450532 ↗MalfunctionMar 25, 2019Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A VATS PROCEDURE ON (B)(6) 2019 AND SUTURE WAS USED. WHILE THE DOCTOR WAS KNOTTING THE SUTURE, IT WAS BROKEN. ANOTHER SUTURE WAS USED TO COMPLETE THE PROCEDURE. NO ADVERSE PATIENT OUTCOME WAS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8450528 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K946173. One submission often covers many models, so check the product and lot details in each record.
- Z-1516-2025 · Mar 7, 2025 · Open, ClassifiedETHIBOND EXCEL GRN 36IN(90CM) USP2-0(M3) D/A MH
- Z-1097-2025 · Dec 20, 2024 · Open, ClassifiedPERMA-HAND Silk Suture, REF: K872H, W723H, 623H, K833H; Perma-hand Silk Suture is indicated for use in general soft tissue approximation and/or ligation, including use in cardiovas
- Z-2486-2020 · Jun 10, 2020 · Open, ClassifiedPERMA-HAND/MERSILK SILK BLU and VIRGIN SILK BLU, Product Codes EH7457G EH7983G FV768 FV769 FV7771 U7058 U7059 W1782 W1784 W1819 W1820 W818 W819 W870
- Z-1842-2019 · Apr 19, 2019 · TerminatedETHIBOND EXCEL ETHIBOND Polvester Suture-Green 75cm USP1 Single Armed CTX Product Code: X865W Product Usage: ETHIBOND EXCEL Suture is intended for use in general soft tissue appr
- Z-1841-2019 · Apr 19, 2019 · TerminatedETHIBOND EXCEL Polyester Suture-ETHIBOND Green 75cm USP1 Single Armed CT-1 Product Code: X425H Product Usage: ETHIBOND EXCEL Suture is intended for use in general soft tissue app
- Z-0747-2019 · Dec 18, 2018 · TerminatedPERMA-HAND Silk Suture Size 5, Black 30" (75cm) Double Armed LR Needles, Product Code 485T Product Usage: PERMA-HAND* suture is indicated for use in general soft tissue approxima
- Z-1839-2015 · May 8, 2015 · TerminatedEthicon Fast Absorbing Plain Gut - MultiPass Needles, Sterile, Absorbable Surgical Suture, 5-0 (1.5 metric), 18" (45 cm), Conventional Cutting, Lot #JD6163, Exp: July 2019. Fast ab
- Z-0492-2015 · Oct 17, 2014 · TerminatedEthicon PERMA-HAND Silk siliconized black braided 10 strands per packet Ethicon LLC- Made in USA.
Other SUTURE, NONABSORBABLE, SILK devices
- Sofsilk S-2782KCovidien LP · SUTURE, NONABSORBABLE, SILK3 recalls0 reports
- PERMA-HAND SA86GEthicon, LLC · SUTURE, NONABSORBABLE, SILK120 reports
- Sofsilk S-1768KCovidien LP · SUTURE, NONABSORBABLE, SILK2 recalls5 reports
- Sofsilk S-316Covidien LP · SUTURE, NONABSORBABLE, SILK2 recalls2 reports
- Sofsilk S-304Covidien LP · SUTURE, NONABSORBABLE, SILK2 recalls2 reports
- Sofsilk S-187Covidien LP · SUTURE, NONABSORBABLE, SILK2 recalls1 report
- Sofsilk S-605Covidien LP · SUTURE, NONABSORBABLE, SILK2 recalls1 report
- Sofsilk S-176Covidien LP · SUTURE, NONABSORBABLE, SILK2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page