PROLENE M8710Recalls & reported problems
Ethicon, LLC · Blue Monofilament (Polypropylene), Nonabsorbable Surgical Suture · Class 2 · Implant
- Adverse event reports
- 18
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 18 adverse event reports that list this exact device (DI 10705031045842), received between Apr 22, 2019 and Apr 20, 2026 — classified as 18 malfunctions.
The most frequently reported specific device problem is “Break” (8 reports).
21 other recalls cover devices cleared under the same FDA submission (K133356); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break8
- Material Separation7
- Material Frayed2
- Packaging Problem1
Patient problems
- No Consequences Or Impact To Patient11
- No Clinical Signs, Symptoms or Conditions7
Recent adverse event reports
The 18 most recent of 18 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 20, 2026Material Separation
IT WAS REPORTED THAT A PATIENT UNDERWENT A CABG PROCEDURE ON (B)(6) 2026 AND SUTURE WAS USED. DURING THE PROCEDURE, IT WAS REPORTED TO THE SALES REPRESENTATIVE THAT DURING A CABG PROCEDURE, THE NEEDLE POPPED OFF FROM THE SUTURE AT THE END OF THE SUTURE WHILE PERFORMING THE ANASTOMOSIS. NO PATIENT CONSEQUENCES WERE REPORTED. THE DEVICE IS NOT RETURNING. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24932292 ↗MalfunctionMay 26, 2023Break; Break
IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON AN UNKNOWN DATE AND SUTURE WAS USED. THE SUTURE BROKE DURING USE. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17010266 ↗MalfunctionFeb 28, 2023Material Frayed; Material Frayed
IT WAS REPORTED THAT A PATIENT UNDERWENT A PEDIATRIC CARDIOVASCULAR PROCEDURE ON (B)(6) 2023 AND SUTURE WAS USED. DURING THE PROCEDURE, THE SUTURE IS FRAYING WHILE SUTURING UNKNOWN TISSUE. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE CONSEQUENCES FOR THE PATIENT. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16453318 ↗MalfunctionFeb 28, 2023Material Frayed; Material Frayed
IT WAS REPORTED THAT A PATIENT UNDERWENT A PEDIATRIC CARDIOVASCULAR PROCEDURE ON (B)(6) 2023 AND SUTURE WAS USED. DURING THE PROCEDURE, THE SUTURE IS FRAYING WHILE SUTURING UNKNOWN TISSUE. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE CONSEQUENCES FOR THE PATIENT. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16453179 ↗MalfunctionDec 19, 2022Material Separation; Material Separation
IT WAS REPORTED THAT A PATIENT UNDERWENT WOUND CLOSURE PROCEDURE ON (B)(6) 2022 AND SUTURE WAS USED. THE PROBLEM OF PULLING OFF SUTURE NEEDLE HAPPENED IN THE SURGERY. CHANGED ANOTHER ONE TO COMPLETE THE SURGERY. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16009999 ↗MalfunctionDec 19, 2022Material Separation; Material Separation
IT WAS REPORTED THAT A PATIENT UNDERWENT A BRAIN HERNIA PROCEDURE ON (B)(6) 2022 AND SUTURE WAS USED. THE PROBLEM OF SUTURE PULLING OFF THE NEEDLE HAPPENED IN THE SURGERY. CHANGED ANOTHER ONE TO COMPLETE THE SURGERY. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16008048 ↗MalfunctionDec 19, 2022Material Separation; Material Separation
IT WAS REPORTED THAT A PATIENT UNDERWENT A BRAIN HERNIA PROCEDURE ON (B)(6) 2022 AND SUTURE WAS USED. THE PROBLEM OF SUTURE PULLING OFF THE NEEDLE HAPPENED IN THE SURGERY. CHANGED ANOTHER ONE TO COMPLETE THE SURGERY. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16007939 ↗MalfunctionApr 2, 2020Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A PEDIATRIC THORACIC PROCEDURE ON (B)(6) 2020 AND THE SUTURE WAS USED. DURING THE SURGERY, THE SUTURE BROKE. THE PROCEDURE WAS DELAYED BY AN UNDETERMINED AMOUNT OF TIME. ANOTHER LIKE SUTURE WAS USED TO COMPLETE THE PROCEDURE WITH NO PATIENT CONSEQUENCES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9916445 ↗MalfunctionApr 2, 2020Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A PEDIATRIC THORACIC PROCEDURE ON (B)(6) 2020 AND THE SUTURE WAS USED. DURING THE SURGERY, THE SUTURE BROKE. THE PROCEDURE WAS DELAYED BY AN UNDETERMINED AMOUNT OF TIME. ANOTHER LIKE SUTURE WAS USED TO COMPLETE THE PROCEDURE WITH NO PATIENT CONSEQUENCES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9916437 ↗MalfunctionApr 2, 2020Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A PEDIATRIC THORACIC PROCEDURE ON (B)(6) 2020 AND THE SUTURE WAS USED. DURING THE SURGERY, THE SUTURE BROKE. THE PROCEDURE WAS DELAYED BY AN UNDETERMINED AMOUNT OF TIME. ANOTHER LIKE SUTURE WAS USED TO COMPLETE THE PROCEDURE WITH NO PATIENT CONSEQUENCES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9916372 ↗MalfunctionApr 2, 2020Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A PEDIATRIC THORACIC PROCEDURE ON (B)(6) 2020 AND THE SUTURE WAS USED. DURING THE SURGERY, THE SUTURE BROKE. THE PROCEDURE WAS DELAYED BY AN UNDETERMINED AMOUNT OF TIME. ANOTHER LIKE SUTURE WAS USED TO COMPLETE THE PROCEDURE WITH NO PATIENT CONSEQUENCES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9916275 ↗MalfunctionApr 2, 2020Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A PEDIATRIC THORACIC PROCEDURE ON (B)(6) 2020 AND THE SUTURE WAS USED. DURING THE SURGERY, THE SUTURE BROKE. THE PROCEDURE WAS DELAYED BY AN UNDETERMINED AMOUNT OF TIME. ANOTHER LIKE SUTURE WAS USED TO COMPLETE THE PROCEDURE WITH NO PATIENT CONSEQUENCES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9916261 ↗MalfunctionApr 2, 2020Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A PEDIATRIC THORACIC PROCEDURE ON (B)(6) 2020 AND THE SUTURE WAS USED. DURING THE SURGERY, THE SUTURE BROKE. THE PROCEDURE WAS DELAYED BY AN UNDETERMINED AMOUNT OF TIME. ANOTHER LIKE SUTURE WAS USED TO COMPLETE THE PROCEDURE WITH NO PATIENT CONSEQUENCES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9916248 ↗MalfunctionApr 2, 2020Break; Break
IT WAS REPORTED THAT THE PATIENT UNDERWENT A PEDIATRIC THORACIC PROCEDURE ON (B)(6) 2020 AND THE SUTURE WAS USED. DURING THE SURGERY, THE SUTURE BROKE. THE PROCEDURE WAS DELAYED BY AN UNDETERMINED AMOUNT OF TIME. ANOTHER LIKE SUTURE WAS USED TO COMPLETE THE PROCEDURE WITH NO PATIENT CONSEQUENCES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9916246 ↗MalfunctionFeb 7, 2020Packaging Problem; Packaging Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON (B)(6) 2020 AND THE SUTURE WAS USED. IT WAS REPORTED THAT DURING SURGERY, WHEN OPENING THE PACKAGE, IT WAS FOUND THAT THERE HAD BEEN A FOREIGN SUBSTANCE LIKE A HAIR ON THE NEEDLE PARK FOAM. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9681957 ↗MalfunctionOct 23, 2019Material Separation; Material Separation
IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN PROCEDURE ON (B)(6) 2019 AND SUTURE WAS USED. DURING THE PROCEDURE, THE SUTURE NEEDLE WAS RELEASING TOO QUICKLY. IT IS UNKNOWN IF ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE CONSEQUENCES FOR THE PATIENT. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9224865 ↗MalfunctionApr 24, 2019Material Separation
IT WAS REPORTED THAT THE PATIENT UNDERWENT A CARDIAC PROCEDURE ON (B)(6) 2019 AND SUTURE WAS USED. THE NEEDLE SEPARATED FROM THE SUTURE DURING USE. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. NO DEVICES WILL BE RETURNED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8544927 ↗MalfunctionApr 22, 2019Material Separation; Material Separation
IT WAS REPORTED THAT THE PATIENT UNDERWENT A CARDIOVASCULAR PROCEDURE ON (B)(6) 2019 AND SUTURE WAS USED. THE NEEDLE SEPARATED FROM THE SUTURE DURING USE. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8537054 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K133356. One submission often covers many models, so check the product and lot details in each record.
- Z-1515-2025 · Mar 7, 2025 · Open, ClassifiedPROLENE BLU 18IN(45CM) USP6-0(M0.7) S/A P-1 PRM
- Z-1096-2025 · Dec 20, 2024 · Open, ClassifiedPROLENE Polypropylene Suture, REF: EH7585H, 8706H, 8833H, 8963H, 8935H PROLENE Suture is indicated for use in general soft tissue approximation and/or ligation, including use in ca
- Z-2459-2018 · May 7, 2018 · TerminatedPROLENE SUTURE 36"(90CM) 4-0 BLUE, D9067
- Z-2462-2018 · May 7, 2018 · TerminatedPROLENE SUTURE 36"(90CM) 3-0 BLU, D9844
- Z-2466-2018 · May 7, 2018 · TerminatedPRONOVA SUTURE BLUE 122CM M1.5, D10189
- Z-2457-2018 · May 7, 2018 · TerminatedPROLENE SUTURE 24"(60CM) 6-0 BLUE, D8688
- Z-2463-2018 · May 7, 2018 · TerminatedPROLENE SUTURE MONO BLUE BV1755 Taperpoint 3/8C, D9995
- Z-2453-2018 · May 7, 2018 · TerminatedPROLENE SUTURE 36"(90CM) 4-0 BLUE, D7768
- Z-2456-2018 · May 7, 2018 · TerminatedPROLENE SUTURE 30"(75CM) 6-0 BLUE, D8647
- Z-2460-2018 · May 7, 2018 · TerminatedPROLENE SUTURE 4"(10CM) 8-0 BLUE, D9662
- Z-2458-2018 · May 7, 2018 · TerminatedPROLENE SUTURE 24"(60CM) 7-0 BLUE, D8881
- Z-2464-2018 · May 7, 2018 · TerminatedPROLENE SUTURE BLUE 18" 7-0 D/A BV-1, DC631
- Z-2450-2018 · May 7, 2018 · TerminatedPROLENE SUTURE 4-36"(90CM) 4-0 BLUE, D5988
- Z-2449-2018 · May 7, 2018 · TerminatedPROLENE SUTURE BLUE 4X90CM M1.5 USP 4/0 DA RB-1 +P, D5981
- Z-2448-2018 · May 7, 2018 · TerminatedPROLENE SUTURE MONO BLUE - BV1755 Taper Point 3/8C, D10031
…and 6 more.
Other SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE devices
- PROLENE 8706HEthicon, LLC · SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE2 recalls294 reports
- PROLENE 8702HEthicon, LLC · SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE3 deaths254 reports
- PROLENE 8556HEthicon, LLC · SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE1 death240 reports
- PROLENE 8805HEthicon, LLC · SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE1 death209 reports
- PROLENE 8521HEthicon, LLC · SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE3 deaths183 reports
- PROLENE 8735HEthicon, LLC · SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE163 reports
- PROLENE 8711HEthicon, LLC · SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE1 recall89 reports
- PROLENE 9702HEthicon, LLC · SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE130 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.