ULTRAPRO UPPM6Recalls & reported problems
Johnson & Johnson International Inc. · Polypropylene partially absorbable medium blue / undyed Plug and Onlay Patch · Class 2 · Implant
All models of ULTRAPRO (18)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10705031132597), received between Oct 25, 2021 and Sep 16, 2024 — classified as 4 injuries.
The most frequently reported specific device problem is “Material Integrity Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Material Integrity Problem1
Patient problems
- Pain2
- Swelling/ Edema2
- Hernia1
- Insufficient Information1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjurySep 16, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY AN ATTORNEY THAT THE PATIENT UNDERWENT RECURRENT INGUINAL HERNIA REPAIR SURGERY ON (B)(6)2017 AND MESH WAS IMPLANTED. IT WAS REPORTED THAT THE PATIENT EXPERIENCED PAIN, RIGHT GROIN PAIN AND BULGE. IT WAS PREVIOUSLY REPORTED THAT THE PATIENT HAD RECURRENT HERNIA REPAIR ON (B)(6)2012, (B)(6)2013, (B)(6)2013, AND ON (B)(6)2016. OTHER PROCEDURES WERE CAPTURED IN A SEPARATE FILE. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: Pain; Swelling/ Edema
MAUDE report 20232887 ↗InjuryAug 8, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY AN ATTORNEY THAT THE PATIENT UNDERWENT RECURRENT LEFT INGUINAL HERNIA REPAIR SURGERY ON (B)(6) 2013 AND MESH WAS IMPLANTED. IT WAS REPORTED THAT THE PATIENT UNDERWENT MESH REPAIR ON (B)(6) 2015 AND MESH WAS IMPLANTED. OTHER PROCEDURE WAS CAPTURED IN A SEPARATE FILE. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: Insufficient Information
MAUDE report 19944220 ↗InjuryOct 29, 2021Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT AN INGUINAL HERNIA REPAIR ON AN UNKNOWN DATE AND THE MESH WAS IMPLANTED. IT WAS REPORTED THAT THE PATIENT EXPERIENCED A RECURRING HERNIA FIVE YEARS POST OP. IT WAS REPORTED THAT THE ORIGINAL MESH WAS COMPLETELY GONE, BUT THE MESH FIXATION SUTURE WAS VISIBLE. IT WAS ALSO REPORTED THAT THE MESH DISAPPEARED. ADDITIONAL INFORMATION WAS REQUESTED.
Patient problems: Hernia
MAUDE report 12724035 ↗InjuryOct 25, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT A HERNIA REPAIR PROCEDURE ON AN UNKNOWN DATE A YEAR AGO AND THE MESH WAS IMPLANTED. IT WAS REPORTED THAT THE PATIENT WAS HAVING PAIN. IT WAS ALSO REPORTED THAT ON (B)(6) 2021 THE PATIENT'S DOCTOR FOUND A BULGE IN THE PATIENT'S ABDOMEN AND RECOMMENDED REMOVAL OF THE MESH. ADDITIONAL INFORMATION HAS BEEN REQUESTED.
Patient problems: Pain; Swelling/ Edema
MAUDE report 12694139 ↗
FDA clearance and classification
The FDA regulates product code FTL (mesh, surgical, polymeric) under 21 CFR 878.3300 as a Class II device. 21 CFR 878.3300 ↗
Devices of this type normally need 510(k) clearance before sale.
Common questions about the ULTRAPRO UPPM6
Has the ULTRAPRO UPPM6 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10705031132597), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the ULTRAPRO UPPM6?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Oct 25, 2021 and Sep 16, 2024. In those reports, the most common specific device problem is “Material Integrity Problem” (1); the most common patient problems are “Pain” (2), “Swelling/ Edema” (2) and “Hernia” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the ULTRAPRO UPPM6?
None of the reports are classified as deaths, 4 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the ULTRAPRO UPPM6 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.
Who makes the ULTRAPRO UPPM6, and is it still sold?
The FDA's device database lists Johnson & Johnson International Inc. as the company responsible for it (brand ULTRAPRO, model UPPM6). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Mesh, surgical, polymeric devices
- PROCEED PVPMJohnson & Johnson International Inc. · Mesh, surgical, polymeric1,233 reports
- PROCEED PCDN1Johnson & Johnson International Inc. · Mesh, surgical, polymeric744 reports
- PROCEED PCDG1Johnson & Johnson International Inc. · Mesh, surgical, polymeric1 recall1 death637 reports
- PROCEED PVPSJohnson & Johnson International Inc. · Mesh, surgical, polymeric622 reports
- ProGrip LPG1510Sofradim Production · Mesh, surgical, polymeric2 deaths616 reports
- VENTRALEX 0010302Davol Inc. · Mesh, surgical, polymeric4 deaths530 reports
- BARD 0112680Davol Inc. · Mesh, surgical, polymeric1 death493 reports
- ProGrip TEM1509GSofradim Production · Mesh, surgical, polymeric2 deaths470 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page