PROLENE W8667Recalls & reported problems

Ethicon, LLC · Blue Monofilament (Polypropylene), Nonabsorbable Surgical Suture · Class 2 · Implant

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10705031201897), received between Dec 4, 2024 and Mar 4, 2026 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Break” (4 reports).

21 other recalls cover devices cleared under the same FDA submission (K133356); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 2 reportsMar 2026: 2 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break4
  • Material Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 4, 2026Break

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN AORTIC VALVE MECHANICAL VALVE REPLACEMENT SURGERY ON (B)(6) 2026 AND SUTURE WAS USED. DURING THE SURGICAL PROCEDURE FOR THE PATIENT, SUTURE WAS USED TO SUTURE THE INTERIOR OF THE HEART. HOWEVER, DURING USE, THE SUTURE WAS PRONE TO BREAKAGE WHEN KNOTTED, AND THE SAME SITUATION PERSISTED FOR SEVERAL CONSECUTIVE SUTURES. THE DOCTOR USED ALTERNATIVE SUTURE INSTEAD. THERE WERE NO PATIENT CONSEQUENCES REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24511895 ↗
  • MalfunctionMar 4, 2026Break

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN AORTIC VALVE MECHANICAL VALVE REPLACEMENT SURGERY ON (B)(6) 2026 AND SUTURE WAS USED. DURING THE SURGICAL PROCEDURE FOR THE PATIENT, SUTURE WAS USED TO SUTURE THE INTERIOR OF THE HEART. HOWEVER, DURING USE, THE SUTURE WAS PRONE TO BREAKAGE WHEN KNOTTED, AND THE SAME SITUATION PERSISTED FOR SEVERAL CONSECUTIVE SUTURES. THE DOCTOR USED ALTERNATIVE SUTURE INSTEAD. THERE WERE NO PATIENT CONSEQUENCES REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24505748 ↗
  • MalfunctionFeb 19, 2026Break

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN AORTIC VALVE MECHANICAL VALVE REPLACEMENT SURGERY ON (B)(6) 2026 AND SUTURE WAS USED. DURING THE PROCEDURE, DURING THE SURGICAL PROCEDURE FOR THE PATIENT, SUTURE WAS USED TO SUTURE THE INTERIOR OF THE HEART. HOWEVER, DURING USE, THE SUTURE WAS PRONE TO BREAKAGE WHEN KNOTTED, AND THE SAME SITUATION PERSISTED FOR SEVERAL CONSECUTIVE SUTURES. THE DOCTOR USED ALTERNATIVE SUTURE INSTEAD. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24388030 ↗
  • MalfunctionFeb 19, 2026Break

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN AORTIC VALVE MECHANICAL VALVE REPLACEMENT SURGERY ON (B)(6) 2026 AND SUTURE WAS USED. DURING THE PROCEDURE, DURING THE SURGICAL PROCEDURE FOR THE PATIENT, SUTURE WAS USED TO SUTURE THE INTERIOR OF THE HEART. HOWEVER, DURING USE, THE SUTURE WAS PRONE TO BREAKAGE WHEN KNOTTED, AND THE SAME SITUATION PERSISTED FOR SEVERAL CONSECUTIVE SUTURES. THE DOCTOR USED ALTERNATIVE SUTURE INSTEAD. NO ADVERSE PATIENT CONSEQUENCES WERE REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24388018 ↗
  • MalfunctionDec 4, 2024Material Separation; Material Separation

    IT WAS REPORTED THAT A PATIENT UNDERWENT A LOBECTOMY PROCEDURE ON (B)(6) 2024 AND SUTURE WAS USED. IT WAS REPORTED THAT THE PROBLEM OF PULLING OFF SUTURE NEEDLE HAPPENED IN SURGERY. CHANGED ANOTHER ONE TO COMPLETE THE SURGERY. THERE WERE NO PATIENT CONSEQUENCES REPORTED. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20843337 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K133356. One submission often covers many models, so check the product and lot details in each record.

  • Z-1515-2025 · Mar 7, 2025 · Open, Classified
    PROLENE BLU 18IN(45CM) USP6-0(M0.7) S/A P-1 PRM
  • Z-1096-2025 · Dec 20, 2024 · Open, Classified
    PROLENE Polypropylene Suture, REF: EH7585H, 8706H, 8833H, 8963H, 8935H PROLENE Suture is indicated for use in general soft tissue approximation and/or ligation, including use in ca
  • Z-2458-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE 24"(60CM) 7-0 BLUE, D8881
  • Z-2463-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE MONO BLUE BV1755 Taperpoint 3/8C, D9995
  • Z-2466-2018 · May 7, 2018 · Terminated
    PRONOVA SUTURE BLUE 122CM M1.5, D10189
  • Z-2450-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE 4-36"(90CM) 4-0 BLUE, D5988
  • Z-2464-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE BLUE 18" 7-0 D/A BV-1, DC631
  • Z-2454-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE BLUE 4X18"5/0 DA RB-2 +PLG, D7879
  • Z-2459-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE 36"(90CM) 4-0 BLUE, D9067
  • Z-2461-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE BLUE 48" 4-0 D/A SH-1, D9746
  • Z-2462-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE 36"(90CM) 3-0 BLU, D9844
  • Z-2451-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE 4-36" (90CM) 3-0 BLUE, D6416
  • Z-2456-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE 30"(75CM) 6-0 BLUE, D8647
  • Z-2457-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE 24"(60CM) 6-0 BLUE, D8688
  • Z-2460-2018 · May 7, 2018 · Terminated
    PROLENE SUTURE 4"(10CM) 8-0 BLUE, D9662

…and 6 more.