Skip to content

STRATAFIX SXMP1B451Recalls & reported problems

Ethicon, LLC · Knotless Tissue Control Device, Dyed Unidirectional (Antibacterial) Synthetic Absorbable Device · Class 2 · Implant

All models of STRATAFIX (181)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705031470088), received between Jun 4, 2025 and Jun 4, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Positioning Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Failure1

Patient problems

  • Failure to Anastomose1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 4, 2025Positioning Failure; Positioning Failure

    IT WAS REPORTED THAT A PATIENT UNDERWENT A RADICAL PROSTATECTOMY PROCEDURE ON (B)(6) 2025 AND BARBED SUTURE WAS USED. DURING A RADICAL PROSTATECTOMY PROCEDURE THAT AFTER SUTURING THE URETHRAL ANASTOMOSIS A LEAK TEST WAS DONE AND A LEAK WAS FOUND. SURGEON OVER SEWED THE ANASTOMOSIS WITH A DIFFERENT SUTURE CODE. ANOTHER LEAK TEST WAS DONE AND NO LEAKS WERE FOUND. THERE WERE NO ADVERSE CONSEQUENCES FOR THE PATIENT. NO DEVICE RETURNING. ADDITIONAL INFORMATION WAS REQUESTED.

    Patient problems: Failure to Anastomose

    MAUDE report 22144613 ↗

Other Suture, absorbable, synthetic, polyglycolic acid devices

All Suture, absorbable, synthetic, polyglycolic acid devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page