Skip to content

BOWTI 172802020Recalls & reported problems

Depuy Spine, LLC · BOWTI ANTERIOR BUTTRESS STAPLE 20mm · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034015644), received between Aug 27, 2024 and Aug 27, 2024 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 27, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ON (B)(6) 2021 THE SURGEON AND SURGICAL TEAM PERFORMED SEVERAL PROCEDURES INCLUDING AN ANTERIOR LUMBAR INTERBODY FUSION AND BONE GRAFT. ALL PROCEDURES WERE PERFORMED PURSUANT TO THE STANDARD OF CARE, WITH NO DEVIATION FROM THE SURGICAL STEPS. THESE PROCEDURES INCLUDED THE IMPLANTATION OF THE DEPUY PRODUCTS. ON (B)(6) 2021 THE SURGEON AND SURGICAL TEAM PERFORMED SEVERAL PROCEDURES INCLUDING REVISION PROCEDURES, OSTEOTOMY PROCEDURES, AND REMOVAL OF HARDWARE. DURING THE SPINE PROCEDURE THE SURGEON CUT THE DEPUY TRANSITION RODS BETWEEN THE C6 AND T1 SPINAL LEVELS. THE CERVICAL PORTION OF THESE WERE REMOVED. THE SET CAPS WERE REMOVED. LATERAL MASS SCREWS AT C4-C5 AND C6 WERE REMOVED. THE SURGEON ALSO OBSERVED THAT THE FUSION MASS AROUND C3-4 WAS WEAK AND WAS EASILY SPREAD APART. THE SURGEON THEN IMPLANTED CERVICAL RODS WITH CONNECTORS TO THE T1 LEVEL. THESE PROCEDURES INCLUDED THE IMPLANTATION OF THE DEPUY PRODUCTS. THIS REPORT IS FOR ONE (1) STAPLE, 20 MM. THIS IS REPORT 2 OF 4 FOR COMPLAINT (B)(4).

    Patient problems: Insufficient Information

    MAUDE report 20081248 ↗

Other APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY devices

All APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page