BENGAL 177300310Recalls & reported problems
Depuy Spine, LLC · BENGAL STACKABLE CAGE SYSTEM CAGE MIDDLE, LARGE 14 x 16 x 10mm, 0 DEGREES · Class 2 · Implant
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034060521), received between Jun 28, 2017 and Jun 28, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Migration or Expulsion of Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Migration or Expulsion of Device1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 28, 2017Migration or Expulsion of Device; Migration or Expulsion of Device
PROCEDURE: CERVICAL CORPECTOMY. THE PATIENT WAS PREVIOUSLY OPERATED ON (B)(6) 2017 FOR A 3/4 CERVICAL FUSION, 4/5 CERVICAL DISC ARTHROPLASTY AND C5-7 CERVICAL FUSION. ON THE DAY THE C5-7 FUSION RESULTED IN A CORPECTOMY OF C6 AND A BENGAL STACKABLE CAGE AND SKYLINE PLATE WAS IMPLANTED. THE PATIENT HAS PRESENTED WITH CAGE SUBSIDENCE AT C5-7. THE SURGEON HAS INDICATED THAT THIS WAS NOT A RESULT OF IMPLANT FAILURE BUT DUE TO THE PATIENT POOR QUALITY BONE. SUBSEQUENTLY THE C5-7 SKYLINE PLATE AND CAGE HAS BEEN REMOVED, A CORPECTOMY OF C7 HAS BEEN PERFORMED AND A LONGER STACKABLE CAGE AND PLATE HAS BEEN IMPLANTED. UNFORTUNATELY THE NURSE HAD DISPOSED OF THE IMPLANTS SO THEY ARE NOT ABLE TO BE RETURNED, HOWEVER AS STATED EARLIER THE SURGEON HAS SAID THAT THE SUBSIDENCE WAS NOT DUE TO ANY IMPLANT FAILURE BUT DUE TO POOR BONE QUALITY.
Patient problems: Failure of Implant
MAUDE report 6674106 ↗
Other SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices
- X-CORE 7160014Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7220016Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 23-32 mm, 2-5 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- X-CORE 7180018Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 33-54 mm, 7-10 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 18-22 mm, 5-8 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- X-CORE 7220018Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7180016Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.