EXPEDIUM 179702640Recalls & reported problems

Medos International Sàrl · EXPEDIUM SPINE SYSTEM MONOAXIAL SCREW 5.5 x 6 x 40mm · Class 2 · Implant

All models of EXPEDIUM (291)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10705034064871), received between Nov 21, 2017 and Oct 18, 2023 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Loose or Intermittent Connection” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loose or Intermittent Connection1
  • Material Twisted/Bent1

Patient problems

  • Failure of Implant1
  • Injury1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 18, 2023Material Twisted/Bent; Material Twisted/Bent

    DEVICE REPORT FROM COLOMBIA REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, DURING THE CLOSURE OF THE SYSTEM AT THE TIME OF THE REDUCTION OF THE BAR AND TORQUING, THE THREAD PITCHES OF THE NUTS WERE FOUND TO BE DAMAGED ALONG WITH THE INTERNAL THREAD OF THE MONO-AXIAL SCREWS. TABLE TESTS OF THE CLOSING PROCESS WERE PERFORMED WITHOUT RESISTANCE OF THE BAR AND THE SAME DIFFICULTY PRESENTED. POLY-AXIAL SCREWS WERE PASSED, AND SYSTEM SHUTDOWN WAS COMPLETED SUCCESSFULLY. NO FURTHER INFORMATION IS AVAILABLE TO REPORT. THIS REPORT IS FOR AN EXPEDIUM SPINE SYSTEM MONOAXIAL SCREW 5.5 X 6 X 40MM. THIS IS REPORT 2 OF 8 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17956367 ↗
  • InjuryNov 21, 2017Loose or Intermittent Connection; Loose or Intermittent Connection

    ON (B)(6) 2016, SURGERY FOR SCOLIOSIS WAS PERFORMED USING THE EXPEDIUM SYSTEM. THE FIXED AREA WAS T11 ¿ L4. RECENTLY, SURGEON CONFIRMED THROUGH AN X-RAY THAT SET SCREWS (PART#: UNK) FIXED AT CAUDAL END WERE LOOSENED AND THAT RODS HAD MOVED IN UPPER POSITION, RESULTING IN LOSS OF THE CORRECTIVE FORCE. THE SURGEON DECIDED TO CONDUCT RE-OPERATION NEXT WEEK BECAUSE SUCH LOOSENED SET SCREWS MIGHT CONTACT THE HEART OF THE PATIENT. HE WILL USE NON-J&J REPLACEMENTS AT THE RE-OPERATION SCHEDULED NEXT WEEK.

    Patient problems: Failure of Implant; Injury

    MAUDE report 7048966 ↗