LEOPARD 186448011Recalls & reported problems
Medos International Sàrl · LEOPARD SYSTEM CURVED, LORDOTIC 28 x 11mm · Class 2 · Implant
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034119083), received between Jan 25, 2018 and Jan 25, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Consequences Or Impact To Patient1
- Not Applicable1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 25, 2018Break; Break
L5/S1 TLIF DR (B)(6), (B)(6) PRIVATE HOSPITAL (B)(6) 2018. DR (B)(6) WAS PERFORMING A TLIF (TRANSFORAMINAL LUMBAR INTERBODY FUSION) AT L5/S1 WITH THE LEOPARD CAGE, SIZE 11MM. HE HAD PREPARED THE SITE AS PER HIS USUAL METHOD, THE SELECTED CAGE WAS PACKED WITH BONE GRAFT AND HE STARTED TO INSERT THE CAGE IN THE USUAL MANNER. THE CAGE BROKE AT THE END THAT WAS ATTACHED TO THE INSTRUMENT, THE END CLOSEST TO THE SURGEON, NOT INSIDE THE PATIENT. HE REMOVED THE INSTRUMENT AND THE BROKEN PARTS OF THE CAGE, PREPARED THE SITE AGAIN AND THEN INSERTED ANOTHER SIZE 11MM CAGE. SURGEON WAS HAPPY THAT HE HAD REMOVED ALL PARTS OF THE INITIAL CAGE. THERE WAS A MINIMAL DELAY TO THE SURGERY. NO AE TO PATIENT. MALE PATIENT. (B)(6).
Patient problems: No Consequences Or Impact To Patient; Not Applicable
MAUDE report 7219549 ↗
Other SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices
- X-CORE 7160014Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7220016Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 23-32 mm, 2-5 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- X-CORE 7180018Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 33-54 mm, 7-10 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 18-22 mm, 5-8 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- X-CORE 7220018Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7180016Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.