Skip to content

COUGAR 187105108Recalls & reported problems

Depuy Spine, LLC · COUGAR SYSTEM SMALL IMPLANT 8mm, 5 DEGREES · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034135342), received between Sep 29, 2017 and Sep 29, 2017 — classified as 1 malfunction.

The most frequently reported specific device problem is “Torn Material” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Torn Material1

Patient problems

  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 29, 2017Torn Material; Torn Material

    ANTERIOR SCOLIOSIS. 173205110 ALIF CAGE SMALL 5DEGREE 10MM THIS ITEM BROKE AS IT WAS POSITIONED IN THE PATIENT AND THEN REMOVED. ALL PIECES OF THE IMPLANT WERE OBTAINED AND DISCARDED BY THE SURGICAL TEAM. A DIFFERENT SIZED CAGE WAS THEN IMPLANTED AT THIS LEVEL OF THE SPINE AND THERE WAS NO DELAY IN SURGERY. 187105108 ALIF CAGE SMALL 5DEGREE 8MM THE THREAD OF THIS ITEM WAS STRIPPED DURING IMPLANTATION WHEN THE INSERTION INSTRUMENT WAS USED TO MANOEUVRE THE IMPLANT INTO POSITION. THE SURGEON NO LONGER NEEDED TO POSITION THE IMPLANT ANY FURTHER AFTER THIS MANOEUVRE AND THEREFORE THE IMPLANT STAYED INSITU AND THERE WAS NO ADDED DELAY IN SURGERY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6904203 ↗

FDA clearance and classification

Cleared through 510(k) K173787 on Jun 11, 2018 (decision: Substantially Equivalent). Submitted by Medos International SARL as “X-MESH® Expandable Cage System, OCELOT® Stackable Cage System, Stackable Cage System, Surgical Titanium Mesh System, BENGAL Stackable Cage System, BENGAL System, CONCORDE® System, CONCORDE® Inline Lumbar Interbody System, CONCORDE® Curve Lumbar Interbody System, CONCORDE® Bullet Lumbar Interbody System, COUGAR® System, COUGAR® LS Lateral Cage System, DEVEX® System, LEOPARD® System, DePuy PULSE Cervical Cage System, DePuy PULSE Lumbar Cage System, LUMBAR I/F CAGE® System”. The FDA review took 179 days. FDA record ↗

Cleared through 510(k) K081917 on May 22, 2009 (decision: Substantially Equivalent). Submitted by Depuy Spine, Inc. as “Depuy Spine Bengal, Concorde, Cougar, Devex And Leopard Systems”. The FDA review took 323 days. FDA record ↗

Cleared through Special 510(k) K030833 on Apr 10, 2003 (decision: Substantially Equivalent). Submitted by Depuyacromed as “Depuy Acromed Vbr System”. The FDA review took 24 days. FDA record ↗

The FDA regulates product code MQP (spinal vertebral body replacement device) under 21 CFR 888.3060 as a Class II device. 21 CFR 888.3060 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the COUGAR 187105108

Has the COUGAR 187105108 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10705034135342), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the COUGAR 187105108?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 29, 2017. That report lists device problem “Torn Material” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the COUGAR 187105108?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the COUGAR 187105108 FDA approved?

It was cleared through Special 510(k) K030833 on Apr 10, 2003; its record lists 3 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the COUGAR 187105108 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the COUGAR 187105108, and is it still sold?

The FDA's device database lists Depuy Spine, LLC as the company responsible for it (brand COUGAR, model 187105108). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices

All SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices →

Sources and updates