Medos International Sàrl · VIPER SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 5.5 x 5 x 45mm · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10705034282459), received between Dec 29, 2020 and Feb 18, 2026 — classified as 3 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Entrapment of Device2
  • Adverse Event Without Identified Device or Use Problem1
  • Crack1
  • Device-Device Incompatibility1

Patient problems

  • Failure of Implant2
  • No Clinical Signs, Symptoms or Conditions2
  • Hypersensitivity/Allergic reaction1
  • Pain1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 18, 2026Device-Device Incompatibility

    IT WAS REPORTED THAT THE VCFFX SCREW COULD NOT BE LOCKED WITH SET SCREW. THERE WAS A THIRTY (30) MINUTE DELAY. THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24379850 ↗
  • InjuryDec 6, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DEVICE REPORT FROM SPAIN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON AN UNKNOWN DATE IN (B)(6) 2023, THE PATIENT UNDERWENT AN OPERATION WITH THE PRODUCTS IN QUESTION. THE PATIENT¿S RADICULAR PAIN IMPROVED AFTER THE SURGERY, BUT THEY HAVE SINCE HAD DISABLING LUMBAR PAIN. TESTS PERFORMED WITH X-RAY AND CT SCAN WERE NORMAL. THE PATIENT SUSPECTS THEY HAVE AN ALLERGY TO TITANIUM. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A VIPER SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 5.5 X 5 X 45MM. THIS IS REPORT 6 OF 8 FOR (B)(4).

    Patient problems: Hypersensitivity/Allergic reaction; Pain

    MAUDE report 18277339 ↗
  • InjuryMay 2, 2023Break; Entrapment of Device; Break; Entrapment of Device

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN AUSTRALIA AS FOLLOWS: IT WAS REPORTED THAT THE PATIENT UNDERWENT SURGERY ON AN UNKNOWN DATE IN 2016 TO TREAT A FRACTURE. ON (B)(6) 2023, THREE SCREWS WERE FOUND TO BE BROKEN. THE SURGEON STATED THAT THEY BROKE DUE TO BEING IN THE PATIENT FOR TOO LONG AND THAT THEY SHOULD HAVE BEEN REMOVED 12 MONTHS POSTOPERATIVELY. THE METALWARE WAS REMOVED, AND BROKEN SCREW SHAFTS REMAINED THE PATIENT. NOTHING NEW WAS IMPLANTED; THE GOAL OF THE ORIGINAL FIXATION HAD BEEN ACHIEVED. THE PATIENT OUTCOME WAS REPORTED TO BE FINE. THIS REPORT INVOLVES ONE VIPER SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 5.5 X 5 X 45MM. THIS IS REPORT 2 OF 3 FOR (B)(4).

    Patient problems: Failure of Implant

    MAUDE report 16852747 ↗
  • InjuryMay 2, 2023Break; Entrapment of Device; Break; Entrapment of Device

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN AUSTRALIA AS FOLLOWS: IT WAS REPORTED THAT THE PATIENT UNDERWENT SURGERY ON AN UNKNOWN DATE IN 2016 TO TREAT A FRACTURE. ON (B)(6) 2023, THREE SCREWS WERE FOUND TO BE BROKEN. THE SURGEON STATED THAT THEY BROKE DUE TO BEING IN THE PATIENT FOR TOO LONG AND THAT THEY SHOULD HAVE BEEN REMOVED 12 MONTHS POSTOPERATIVELY. THE METALWARE WAS REMOVED, AND BROKEN SCREW SHAFTS REMAINED THE PATIENT. NOTHING NEW WAS IMPLANTED; THE GOAL OF THE ORIGINAL FIXATION HAD BEEN ACHIEVED. THE PATIENT OUTCOME WAS REPORTED TO BE FINE. THIS REPORT INVOLVES ONE VIPER SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 5.5 X 5 X 45MM. THIS IS REPORT 1 OF 3 FOR (B)(4).

    Patient problems: Failure of Implant

    MAUDE report 16852741 ↗
  • MalfunctionDec 29, 2020Crack; Crack

    DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED ON (B)(6) 2020 THAT THE PATIENT UNDERWENT FOR A SURGERY. DURING THE SURGERY, CROSS THREADING OF SCREW CAP LEADING TO TULIP HEAD OF SCREW DAMAGE. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH 10 MINUTES DELAY. THERE WERE NO PATIENT CONSEQUENCES REPORTED. CONCOMITANT DEVICE REPORTED: UNKNOWN SETSCREWS (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY UNKNOWN). UNKNOWN RODS (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY UNKNOWN). THIS COMPLAINT INVOLVES TWO (2) DEVICES. THIS REPORT IS FOR (1) MIS TI CFX FEN POLY 5X45. THIS REPORT IS 1 OF 1 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11088097 ↗

Other ORTHOSIS, SPINAL PEDICLE FIXATION devices

All ORTHOSIS, SPINAL PEDICLE FIXATION devices →