EXPEDIUM VERSE 199723650SRecalls & reported problems
Medos International Sàrl · EXPEDIUM VERSE SPINE SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 6.0 x 50mm · Class 2 · Implant
All models of EXPEDIUM VERSE (90)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 10
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 10705034443522), received between Apr 20, 2019 and Jan 8, 2024 — classified as 10 injuries.
The most frequently reported specific device problem is “Break” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem5
- Break3
- Insufficient Device Problem Information1
- Migration1
Patient problems
- Insufficient Information2
- Low Blood Pressure/ Hypotension2
- No Code Available2
- Nonunion/Delayed-union Bone Fracture2
- Pain2
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Nerve Damage1
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
InjuryJan 8, 2024Insufficient Device Problem Information; Insufficient Device Problem Information
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN SWITZERLAND AS FOLLOWS: THIS REPORT IS BEING FILED AFTER THE REVIEW OF A CLINICAL EVALUATION REPORT (CER) FROM A DATABASE RELATED RESEARCH ACTIVITY (DRRA): SPINE TANGO SOA REPORT - TLIF. THE FOLLOWING COMPLICATIONS HAVE BEEN IDENTIFIED: IMPLANT FAILURE COMPLICATION TIME/INTERVENTION. REPEAT SURGERY THIS REPORT INVOLVES ONE EXPEDIUM VERSE SPINE SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 6.0 X 50MM THIS IS REPORT 2 OF 4 FOR (B)(4).
Patient problems: Insufficient Information
MAUDE report 18466236 ↗InjuryJan 8, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN SWITZERLAND AS FOLLOWS: THIS REPORT IS BEING FILED AFTER THE REVIEW OF A CLINICAL EVALUATION REPORT (CER) FROM A DATABASE RELATED RESEARCH ACTIVITY (DRRA): SPINE TANGO SOA REPORT - TLIF THE FOLLOWING COMPLICATIONS HAVE BEEN IDENTIFIED: NON-UNION; COMPLICATION TIME/INTERVENTION; REPEAT SURGERY; THIS REPORT INVOLVES ONE EXPEDIUM VERSE SPINE SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 6.0 X 50MM; THIS IS REPORT 2 OF 3 FOR (B)(4).
Patient problems: Nonunion/Delayed-union Bone Fracture
MAUDE report 18462987 ↗InjuryJan 5, 2024Migration; Migration
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN SWITZERLAND AS FOLLOWS: THIS REPORT IS BEING FILED AFTER THE REVIEW OF A CLINICAL EVALUATION REPORT (CER) FROM A DATABASE RELATED RESEARCH ACTIVITY (DRRA): SPINE TANGO SOA REPORT - TLIF. THE FOLLOWING COMPLICATIONS HAVE BEEN IDENTIFIED: IMPLANT MALPOSITION, COMPLICATION TIME/INTERVENTION, AND REPEAT SURGERY. THIS IS FOR DEPUY SYNTHES SPINE EXPEDIUM /OTHER, EXPEDIUM VERSE FENESTRATED AND MOSS MIAMI SI /OTHER PRODUCTS. THIS IS REPORT 2 OF 4 FOR COMPLAINT (B)(4).
Patient problems: Insufficient Information
MAUDE report 18455581 ↗InjuryJan 5, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THIS REPORT IS BEING FILED AFTER THE REVIEW OF A CLINICAL EVALUATION REPORT (CER) FROM A DATABASE RELATED RESEARCH ACTIVITY (DRRA): SPINE TANGO SOA REPORT - TLIF. THE FOLLOWING COMPLICATIONS HAVE BEEN IDENTIFIED: NON-UNION, COMPLICATION TIME/INTERVENTION, REPEAT SURGERY, THIS REPORT IS FOR ONE (1) 5.5 EXP VERSE FEN SCR 6.0X50. THIS IS REPORT 2 OF 3 FOR COMPLAINT (B)(4).
Patient problems: Nonunion/Delayed-union Bone Fracture
MAUDE report 18454949 ↗InjuryJan 5, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN SWITZERLAND AS FOLLOWS: THIS REPORT IS BEING FILED AFTER THE REVIEW OF A CLINICAL EVALUATION REPORT (CER) FROM A DATABASE RELATED RESEARCH ACTIVITY (DRRA): SPINE TANGO SOA REPORT - TLIF. THE FOLLOWING COMPLICATIONS HAVE BEEN IDENTIFIED: NEUROCOMPRESSION. COMPLICATION TIME/INTERVENTION. REPEAT SURGERY. THIS IS FOR DEPUY SYNTHES SPINE EXPEDIUM VERSE SPINE SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 6.0 X 50MM. THIS IS REPORT 3 OF 4 FOR (B)(4).
Patient problems: Nerve Damage
MAUDE report 18453861 ↗InjurySep 20, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT THIS WAS A SPINAL FUSION(T10) FOR TREATING DEGENERATIVE DISEASE ON (B)(6) 2022. TWO SCREWS WERE APPLIED TO LESION. THEN, THE PATIENT'S BLOOD PRESSURE DECREASED DURING SURGERY. THE SURGEON FINISHED THE OPERATION IMMEDIATELY. NO SURGICAL DELAY WAS REPORTED. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT INVOLVES ONE EXPEDIUM VERSE SPINE SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 6.0 X 50MM. THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: Low Blood Pressure/ Hypotension
MAUDE report 15453848 ↗InjurySep 20, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT THIS WAS A SPINAL FUSION(T10) FOR TREATING DEGENERATIVE DISEASE ON (B)(6) 2022. TWO SCREWS WERE APPLIED TO LESION. THEN, THE PATIENT'S BLOOD PRESSURE DECREASED DURING SURGERY. THE SURGEON FINISHED THE OPERATION IMMEDIATELY. NO SURGICAL DELAY WAS REPORTED. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT INVOLVES ONE EXPEDIUM VERSE SPINE SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 6.0 X 50MM. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: Low Blood Pressure/ Hypotension
MAUDE report 15453826 ↗InjuryDec 14, 2021Break; Break
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT THE PATIENT UNDERWENT SURGERY ON (B)(6) 2021 WITH THE IMPLANTS IN QUESTION TREATING DORSAL SPONDYLODESIS L5/ S1. ON AN UNKNOWN DATE, TWO (2) EXPEDIUM SCREWS BROKE IN THE PATIENT. THE SCREWS WERE REMOVED FROM THE PATIENT ON (B)(6) 2021 AND THE PATIENT RECEIVED A NEW FIXATEUR INTERN. THE PATIENT OUTCOME WAS REPORTED AS GOOD. THERE IS NO FURTHER INFORMATION AVAILABLE. THIS REPORT IS FOR ONE (1) EXPEDIUM VERSE SPINE SYSTEM FENESTRATED CORTICAL FIX POLYAXIAL SCREW 6.0 X 50MM. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 13003292 ↗InjuryApr 20, 2019Break; Break
IT WAS REPORTED THAT THE SURGEON PERFORMED A SINGLE LEVEL FUSION AT L5S1 6 MONTHS PREVIOUSLY USING EXPEDIUM VERSE ADVANCED IMPLANTS. AT THE 6 MONTH FOLLOW UP THE SURGEON TOOK X RAYS AND NOTED BOTH THE TIPS OF THE 6.0 X 50 MM S1 SCREWS HAD BROKEN. THE PATIENT IS NOW EXPERIENCING BACK PAIN AND WE ARE LOOKING TO REVISE THE CASE IN THE FUTURE.
Patient problems: No Code Available; Pain
MAUDE report 8534172 ↗InjuryApr 20, 2019Break; Break
IT WAS REPORTED THAT THE SURGEON PERFORMED A SINGLE LEVEL FUSION AT L5S1 6 MONTHS PREVIOUSLY USING EXPEDIUM VERSE ADVANCED IMPLANTS. AT THE 6 MONTH FOLLOW UP THE SURGEON TOOK X RAYS AND NOTED BOTH THE TIPS OF THE 6.0 X 50 MM S1 SCREWS HAD BROKEN. THE PATIENT IS NOW EXPERIENCING BACK PAIN AND WE ARE LOOKING TO REVISE THE CASE IN THE FUTURE.
Patient problems: No Code Available; Pain
MAUDE report 8534171 ↗
Other Appliance, fixation, spinal intervertebral body devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- XLP 7565050Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430344Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- ATLANTIS® Anterior Cervical Plate System 876-170Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- XLP 7565060Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430113Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page