VIPER PRIME 186770340Recalls & reported problems
Medos International Sàrl · VIPER PRIME CFX X-TAB POLYAXIAL SCREW 5.5 7 x 40mm · Class 2 · Implant
All models of VIPER PRIME (60)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034509532), received between Mar 20, 2023 and Mar 20, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Migration1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 20, 2023Migration; Migration
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, THIS WAS A FUSION OF PELVIS FOR PELVIC FRACTURE. PROCEDURE WAS COMPLETED SUCCESSFULLY WITH OUT ANY SURGICAL DELAY. AFTER SURGERY, ON (B)(6) 2023, THE SURGEON SUSPECTED THAT THE SCREW IN QUESTION MIGHT BE OUT OF PROPER POSITION. ON (B)(6) 2023, IT WAS CONFIRMED THAT THE SCREW WAS OUT OF PROPER POSITION, AND A REOPERATION WAS PERFORMED ON THE SAME DAY. IN THE REOPERATION, A SCREW OF THE SAME PRODUCT CODE WAS RE-INSERTED PROPERLY, AND THE REOPERATION WAS COMPLETED SUCCESSFULLY. POSTOPERATIVE CT ALSO SHOWED NO PROBLEMS. THE SURGEON COMMENTED AS FOLLOWS; THERE WAS NO PROBLEMS IN THE SCREW OR INSTRUMENTS. THE SURGEON THOUGHT THAT THE SCREW HAD BEEN INSERTED PROPERLY AT THE TIME OF THE INITIAL SURGERY, BUT THE SCREW BECAME OUT OF POSITION BECAUSE THE PATIENT'S BONE HARDENING WAS SEVERE. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR ONE (1) VIPER PRIME CFX X-TAB POLYAXIAL SCREW 5.5 7 X 40MM. THIS IS REPORT 1 OF 1 FOR COMPLAINT: (B)(4).
Patient problems: Failure of Implant
MAUDE report 16577554 ↗
Other APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- Mariner RDX MX1-000040Seaspine Orthopedics Corporation · Appliance, fixation, spinal intervertebral body1 recall0 reports
- Mariner RDX MX1-000030Seaspine Orthopedics Corporation · Appliance, fixation, spinal intervertebral body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430112Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430224Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- XLP 7565050Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page