CONDUIT TFT30101TRecalls & reported problems
Medos International Sàrl · CONDUIT Curved TLIF Transforaminal Lumbar Interbody Implant Inserter Outer Shaft · Class 2
All models of CONDUIT (27)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 20
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 20 adverse event reports that list this exact device (DI 10705034557489), received between Mar 8, 2023 and Feb 12, 2026 — classified as 1 injury, 19 malfunctions.
The most frequently reported specific device problem is “Device-Device Incompatibility” (14 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Device-Device Incompatibility14
- Material Deformation6
- Material Twisted/Bent4
- Material Integrity Problem1
- No Apparent Adverse Event1
Patient problems
- No Clinical Signs, Symptoms or Conditions17
- Insufficient Information2
- Nerve Damage1
Recent adverse event reports
The 20 most recent of 20 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 12, 2026Device-Device Incompatibility; Material Deformation
IT WAS REPORTED THAT DURING A CONDUIT TLIF DEGENERATIVE CASE PERFORMED ON (B)(6) 2026 THE TIP OF THE INSERTION INSTRUMENT BENT DURING INSERTION OF THE CONDUIT TLIF CAGE, MAKING REMOVAL FROM THE IMPLANT DIFFICULT. THE INSTRUMENT WAS DAMAGED AND COULD NOT BE USED IN FUTURE SURGERIES. THE BACKUP INNER SHAFT WAS ALSO BENT, AND THE TIP OF THE OUTER SHAFT WAS DAMAGED DURING THE PROCEDURE. THERE WAS NO CONSEQUENCE TO THE PATIENT, NO DELAY IN SURGERY, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH THE AFFECTED INSTRUMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24325019 ↗MalfunctionFeb 4, 2026Material Deformation
IT WAS REPORTED THAT WHILE HAMMERING THE CONDUIT TLIF IMPLANT INSERTER THE INNER SHAFT BENT AND IT WAS VERY HARD TO DETACH THE INSERTER FROM THE IMPLANT. THERE WAS A 15 MINUTES OF SURGICAL DELAY. THERE WAS NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24260483 ↗MalfunctionDec 29, 2025Device-Device Incompatibility; Material Deformation; Device-Device Incompatibility; Material Deformation
IT WAS REPORTED THE CAGE INSERTER IS BENT AND DOESN'T HOLD THE CAGE. PROCEDURE WAS COMPLETED SUCCESSFULLY WITH NO SURGICAL DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23907753 ↗MalfunctionNov 17, 2025Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT THIS WAS AN INTERBODY FUSION (L5/S) FOR LUMBAR DEGENERATIVE DISEASE ON (B)(6) 2025. IN THE SURGERY, DUE TO THE SEVERE DEGENERATION, IT WAS CONFIRMED THAT THE ANGLE FORMED BY THE CRANIOCAUDAL ENDPLATES WAS MISALIGNED WITH THE ANGLE AT WHICH THE INSERTERS IN QUESTION COULD BE INSERTED. THE SURGEON ATTEMPTED TO ROTATE THE IMPLANT, BUT THE MISALIGNMENT MADE IT DIFFICULT. THE SURGEON FINALLY MANAGED TO ROTATE THE IMPLANT BY HAMMERING IT AND PLACED IN THE PROPER POSITION. WHEN THE INSERTER WAS REMOVED FROM THE IMPLANT, ITS TIP WAS DEFORMED. THIS WAS THOUGHT TO BE DUE TO THE TIP DEFORMING TO ACCOMMODATE THE DIFFERENCE IN ANGLE. BECAUSE THE TIP OF THE INNER SHAFT HAD BECOME DEFORMED, IT COULD NO LONGER BE REMOVED FROM THE OUTER SHAFT. THE OPERATION WAS COMPLETED WITHOUT ANY PROBLEMS, AS THE IMPLANT DID NOT BECOME STUCK OR REQUIRE REPLACEMENT. THE SURGERY WAS COMPLETED SUCCESSFULLY WITHIN 30 MINUTES SURGICAL DELAY. THE OUTER SHAFT WAS NOT DAMAGED. HOWEVER, THE INNER SHAFT, WHICH CAN NORMALLY BE PULLED APART, COULD NO LONGER BE REMOVED. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23571130 ↗MalfunctionJul 10, 2025Material Deformation; Material Deformation
IT WAS REPORTED THAT THIS WAS AN UNKNOWN SURGERY PERFORMED ON (B)(6) 2025. IN THE SURGERY, WHEN THE SURGEON ATTEMPTED TO ATTACH THE CONDUIT CURVED CAGE IMPLANT TO THE INSERTER, THE INSERTER WAS NOT TURN AND THE CONDUIT CURVED CAGE IMPLANT COULD NOT BE ATTACHED. THEREFORE, THE SALES REP EXPLAINED THE INSTALLATION PROCEDURE TO THE SURGEON AGAIN, BUT THE SURGEON STILL HAD DIFFICULTY WITH INSTALLATION. HOWEVER, THE SURGEON WAS ABLE TO ATTACH IT, AND THE SALES REP ALSO CHECKED THE CONDITION AND CONFIRMED WITH THE SURGEON THAT THERE WERE NO VISIBLE PROBLEMS AND THAT THERE WAS NO WOBBLING. AFTER PLACING THE IMPLANT, THE SURGEON TRIED TO REMOVE THE INSERTER BUT IT WOULD NOT COME OFF. THE SURGEON HAD EXPERIENCE WITH THE CONDUIT CURVED AND WAS FAMILIAR WITH ITS USE. THE SALES REP ALSO EXPLAINED HOW TO REMOVE IT, BUT THE SURGEON WAS UNABLE TO DO SO SUCCESSFULLY. HOWEVER, AFTER APPLYING MORE FORCE, THE INSERTER WAS ABLE TO BE REMOVED. AFTER SURGERY, IT WAS CONFIRMED THAT THE TIP OF THE INSERTER WAS BENT. THE SURGERY WAS COMPLETED SUCCESSFULLY WITHOUT ANY SURGICAL DELAY. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22469680 ↗MalfunctionJul 8, 2025No Apparent Adverse Event; No Apparent Adverse Event
IT WAS REPORTED THAT THE IMPLANT OUTER SHAFT AND THE KNOB INVERTER WHEN TWISTED/ ASSEMBLED GOT STUCK, AND DURING THE PROCESS OF DISASSEMBLY IT RELEASED FILINGS/ METAL PARTS. SOME ARE STUCK ON THE KNOB INSERTER. THE SURGERY WAS NOT DELAYED, AND THERE WAS NO PATIENT CONSEQUENCE. UPON RETURN TO THE MANUFACTURER, IT WAS NOTED THAT THE IMPLANT INSERTER OUTER SHAFT WAS STRIPPED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22439010 ↗MalfunctionJun 4, 2025Material Deformation; Material Deformation
ADDITIONAL INFORMATION RECEIVED STATES THAT THE THE SURGERY COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22141030 ↗MalfunctionMay 13, 2025Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED DURING A TLIF MIS PROCEDURE ON (B)(6) 2025 THE INSTRUMENT FOR BOTH TRAIL AND FINAL INSERTION OF THE IMPLANT BECAME DAMAGED IN A WAY THAT IT IS NOT LONGER USABLE FOR FUTURE CASES. NO PATIENT CONSEQUENCES. SURGERY WAS COMPLETED SUCCESSFULLY WITHOUT SURGICAL DELAY OR COMPLICATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22008456 ↗MalfunctionJan 30, 2025Material Deformation; Material Deformation
IT WAS REPORTED THAT THIS WAS A TLIF (L5/S) FOR LUMBAR CANAL STENOSIS ON (B)(6) 2025. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH NO SURGICAL DELAY. AFTER THE SURGERY, REGARDING THE IMPLANT INSERTER INNER SHAFTS, THE TIPS OF THE PART THAT GRASP IMPLANTS WERE FOUND TO HAVE BEEN BENT. DURING THE SURGERY, NO PROBLEMS HAD BEEN OBSERVED, SO THE SALES REP DID NOT NOTICE THE BENDS. THE SALES REP NOTICED THE BENDS WHEN THE PRODUCTS IN QUESTION WERE RETURNED AFTER INSTRUMENT WASHING. PATIENT IS LISTED AS STABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21277475 ↗MalfunctionJan 2, 2025Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED DURING A SPINAL FUSION PROCEDURE ON (B)(6) 2024, THE CONDUIT TLIF INSERTER CANNOT BE DISMANTLED. THE PROCEDURE WAS COMPLETED WITH NO CONSEQUENCES TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21055461 ↗MalfunctionSep 18, 2024Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE INSERTERS ARE WORN AND THE IMPLANT CAN NO LONGER BE PROPERLY SECURED. THERE WERE NO PATIENT CONSEQUENCES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20248236 ↗MalfunctionSep 18, 2024Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE INSERTERS ARE WORN AND THE IMPLANT CAN NO LONGER BE PROPERLY SECURED. THERE WERE NO PATIENT CONSEQUENCES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20248095 ↗MalfunctionSep 18, 2024Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE INSERTERS ARE WORN AND THE IMPLANT CAN NO LONGER BE PROPERLY SECURED. THERE WERE NO PATIENT CONSEQUENCES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20248001 ↗MalfunctionSep 18, 2024Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE INSERTERS ARE WORN AND THE IMPLANT CAN NO LONGER BE PROPERLY SECURED. THERE WERE NO PATIENT CONSEQUENCES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20247953 ↗InjuryMay 20, 2024Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT THE PATIENT UNDERWENT A SPINAL FUSION SURGERY ON (B)(6) 2024 FOR A SINGLE-SEGMENTAL MIS TLIF TREATMENT. THE PRE-PREPARED INTERVERTEBRAL DISC SPACE L4-L5 WAS PREPARED WITH AN INTERVERTEBRAL DISC KNIFE TO A HEIGHT OF 11MM. THE INSTRUMENT TECHNICIAN THEN CORRECTLY ASSEMBLED THE CONDUIT IMPLANT HOLDER AND CONNECTED IT TO A CONDUIT TLIF CAGE 9MM/10X28/8°. IT WAS ENSURED THAT THE ROTARY KNOB OF THE IMPLANT HOLDER WAS TURNED CLOCKWISE AS TIGHTLY AS POSSIBLE. THE DOCTOR PLACED THE IMPLANT AT THE ENTRANCE TO THE INTERVERTEBRAL DISC SPACE AND HIT THE IMPLANT KNOB OF THE IMPLANT HOLDER WITH THE HAMMER. THE CONDUIT TLIF CAGE ONLY PENETRATED THE INTERVERTEBRAL DISC SPACE WITH THE "BULLET NOSE" BEFORE THE RIGID CONNECTION BETWEEN THE CAGE AND THE IMPLANT HOLDER BECAME LOOSE AND THE IMPLANT HOLDER SWIVELED 90° INTO THE SPINAL CANAL IN AN UNPLANNED MANNER. DR REMOVED THE IMPLANT HOLDER WITH CAGE WITH A KNOCK-OUT HAMMER AND HAD THE CAGE CONNECTED FROM THE INSTRUMENT ATRINE TO ANOTHER IDENTICAL IMPLANT HOLDER. WITH THIS "NEW" IMPLANT HOLDER, INSERTING THE SAME CONDUIT CAGE WAS POSSIBLE WITHOUT ANY PROBLEMS. WHEN THE CAGE WAS FLIPPED THREE TIMES EARLY, A SENSITIVE ROOT INJURY OCC
Patient problems: Nerve Damage
MAUDE report 19352590 ↗MalfunctionDec 20, 2023Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM GERMANY REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023 WHILE INSERTING THE IMPLANT, THE IMPLANT TWISTED 90 DEGREES INTO THE VERTEBRAL BODY. THE IMPLANT WAS ATTACHED FIRMLY TO THE IMPLANT INSERTER, IT WAS NO LONGER POSSIBLE TO ROTATE THE IMPLANT PROPERLY INTRAOPERATIVELY. IT WAS NOT POSSIBLE TO ATTACH THE IMPLANT CORRECTLY TO THE IMPLANT INSERTER. THE PROCEDURE WAS COMPLETED SUCCESSFULLY AFTER A SURGICAL DELAY OF 40 MINUTES. THE IMPLANT WAS TWISTED 90 DEGREES INTO THE VERTEBRAL BODY. THIS REPORT IS FOR A CONDUIT CURVED TLIF TRANSFORAMINAL LUMBAR INTERBODY IMPLANT INSERTER OUTER SHAFT. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: Insufficient Information
MAUDE report 18365963 ↗MalfunctionDec 20, 2023Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM GERMANY REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023 WHILE INSERTING THE IMPLANT, THE IMPLANT TWISTED 90 DEGREES INTO THE VERTEBRAL BODY. THE IMPLANT WAS ATTACHED FIRMLY TO THE IMPLANT INSERTER, IT WAS NO LONGER POSSIBLE TO ROTATE THE IMPLANT PROPERLY INTRAOPERATIVELY. IT WAS NOT POSSIBLE TO ATTACH THE IMPLANT CORRECTLY TO THE IMPLANT INSERTER. THE PROCEDURE WAS COMPLETED SUCCESSFULLY AFTER A SURGICAL DELAY OF 40 MINUTES. THE IMPLANT WAS TWISTED 90 DEGREES INTO THE VERTEBRAL BODY. THIS REPORT IS FOR A CONDUIT CURVED TLIF TRANSFORAMINAL LUMBAR INTERBODY IMPLANT INSERTER OUTER SHAFT. THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: Insufficient Information
MAUDE report 18365929 ↗MalfunctionApr 26, 2023Device-Device Incompatibility; Device-Device Incompatibility
IT WAS FURTHER REPORTED THAT THE PATIENT WAS NOT AFFECTED BY THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16814623 ↗MalfunctionApr 26, 2023Device-Device Incompatibility; Device-Device Incompatibility
IT WAS FURTHER REPORTED THAT THE PATIENT WAS NOT AFFECTED BY THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16814619 ↗MalfunctionMar 8, 2023Device-Device Incompatibility; Device-Device Incompatibility
THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16504395 ↗
Other Intervertebral fusion device with bone graft, lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page