Synthes GmbH · SELF-RETAINING SCREWDRIVER · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10705034731377), received between Dec 11, 2019 and Dec 18, 2025 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Compatibility Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Compatibility Problem3
  • Device-Device Incompatibility2
  • Material Twisted/Bent1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Consequences Or Impact To Patient3

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 18, 2025Compatibility Problem; Compatibility Problem

    IT WAS REPORTED THAT DURING THE CASE, WHILE USING THE CASPAR DRIVER, A DIFFICULTY IN SECURING THE CASPAR PINS WAS ENCOUNTERED. THEY HAD TO USE BONE WAX TEMPORARILY TO HOLD THE PINS IN PLACE AND PREVENT THEM FROM FALLING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23844067 ↗
  • MalfunctionJun 16, 2025Compatibility Problem; Compatibility Problem

    IT WAS REPORTED THAT DURING THE CASE, WHILE USING THE CASPAR DRIVER, THERE WAS A DIFFICULTY SECURING THE CASPAR PINS. SURGEON HAD TO USE BONE WAX TEMPORARILY TO HOLD THE PINS IN PLACE AND PREVENT THEM FROM FALLING. ADDITIONALLY, ANOTHER DRIVER DID NOT FIT PROPERLY WITH THE LOCKING NUT OF THE RETAINERS. SURGEON HAD TO FORCEFULLY INSERT IT, LIKELY DUE TO A SLIGHT DEFORMATION AT THE TIP.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22211688 ↗
  • MalfunctionNov 18, 2022Compatibility Problem; Compatibility Problem

    IT WAS REPORTED THAT ON (B)(6) 2022, THE DISTRIBUTOR REPORTED THAT THERE WAS A NON-FUNCTIONING SELF-RETAINING SCREWDRIVER. THE DRIVER WAS NOT HOLDING THE PINS (SCREWS). A SECOND SET WAS USED AND IT RETAINED THE SCREWS, SO IT WAS USED TO COMPLETE THE PROCEDURE ON (B)(6) 2022 SUCCESSFULLY. THE PROBLEM WAS IDENTIFIED PRE-OPERATIVELY; THERE WAS NO DELAY OF THE CASE AND THERE WAS NO CONSEQUENCE TO THE PATIENT. UPON CURSORY EXAMINATION, THE TAB AT THE END OF THE SHAFT THAT SHOULD GRAB THE HEAD OF THE SCREW WAS STRAIGHT AND APPEARED TO BE WHY THE INSTRUMENT WAS NOT FUNCTIONING. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT INVOLVES ONE SELF-RETAINING SCREWDRIVER. THIS IS REPORT 1 OF 1 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15824438 ↗
  • MalfunctionJul 8, 2020Material Twisted/Bent; Material Twisted/Bent

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED ON (B)(6) 2020 THAT DURING INSPECTION, THE SELF RETAINING SCREWDRIVER WAS FOUND TO BE WORN. THERE WAS NO PATIENT INVOLVEMENT. THERE IS NO FURTHER INFORMATION AVAILABLE. THIS COMPLAINT INVOLVES ONE (1) DEVICE. THIS REPORT IS FOR ONE (1) SELF-RETAINING SCREWDRIVER. THIS IS REPORT 1 OF 1 FOR (B)(4).

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10247684 ↗
  • MalfunctionDec 16, 2019Device-Device Incompatibility; Device-Device Incompatibility

    FORCEPS WERE USED TO HOLD THE PIN IN PLACE AND THEN THE INSTRUMENT WAS USED TO DRIVE THE PIN IN.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9473184 ↗
  • MalfunctionDec 11, 2019Device-Device Incompatibility; Device-Device Incompatibility

    FORCEPS WERE USED TO HOLD THE PIN IN PLACE AND THEN THE INSTRUMENT WAS USED TO DRIVE THE PIN IN.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9453937 ↗