Synex 04.807.123Recalls & reported problems
Synthes GmbH · SYNEX(TM) W/SM ENDPLATE/OPEN -5 DEG/23MM-31MM HEIGHT (TI) · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034753027), received between Jan 30, 2017 and Jan 30, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Device Operates Differently Than Expected” (1 report).
11 other recalls cover devices cleared under the same FDA submission (K003836); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device Operates Differently Than Expected1
Patient problems
- Failure of Implant1
- No Code Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 30, 2017Device Operates Differently Than Expected; Device Operates Differently Than Expected
IT WAS REPORTED THAT ON THE MORNING OF (B)(6) 2017, A PATIENT UNDERWENT A T7 CORPECTOMY WITH T5-T9 POSTERIOR SPINAL FUSION AND FIXATION. EXPEDIUM TITANIUM (TI) PEDICLE SCREWS WERE PLACED BILATERALLY AT T5, T6, T8 & T9. TWO (2) 5.5MM TI RODS WERE PLACED USING TI EXPEDIUM SET SCREWS AND SFX CONNECTOR WAS PLACED OVER THE T7 CORPECTOMY SPACE (OVER THE CAGE). WHILE THE PATIENT WAS RECOVERING POST-OPERATIVELY, IT WAS REPORTED THAT SHE COULD NOT MOVE HER LOWER EXTREMITIES AND THAT A COMPUTERIZED TOMOGRAPHY (CT) SCAN SHOWED THAT A T5 PEDICLE SCREW WAS ON THE MEDIAL BORDER OF THE PEDICLE AND POSSIBLY TOUCHING THE SPINAL CORD. SHE WAS RETURNED TO SURGERY THAT SAME DAY. THE SURGEON REPOSITIONED THE SCREW IN THE PEDICLE UNDER ROUTINE FLUOROSCOPY. HE FOUND THE SYNEX CAGE (04.807.123) WAS NOT EXPANDED CORRECTLY. HE TRIED TO REPOSITION IT. THE ORIGINAL VOID IN THE FIRST SURGERY, EARLIER THAT DAY WAS 28MM. THIS CAGE WAS CHOSEN BECAUSE IT WAS LESS THAN THE VOID AND EXPANDED BEYOND THE NON-DISTRACTED VOID HEIGHT. HOWEVER, ALTHOUGH THE CAGE WOULD EXPAND IT WOULD NOT LOCK INTO PLACE. THE ROD WAS REMOVED ON THE PATIENT¿S RIGHT SIDE AND THE SET SCREWS WERE LOOSENED ON THE PATIENTS LEFT SIDE. HE REMOVED
Patient problems: Failure of Implant; No Code Available
MAUDE report 6287934 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K003836. One submission often covers many models, so check the product and lot details in each record.
- Z-0113-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 37mm - 52mm, Catalog number 04.808.006. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable
- Z-0112-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 29mm - 44mm, Catalog number 04.808.005. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable
- Z-0110-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 21mm - 29mm, Catalog number 04.808.003. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable
- Z-0115-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 58mm - 84mm, Catalog number 04.808.008. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable
- Z-0117-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 84mm - 110mm, Catalog number 04.808.010. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstabl
- Z-0108-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 14mm - 19mm, Catalog number 04.808.001. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable
- Z-0111-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 25mm - 33mm, Catalog number 04.808.004. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable
- Z-0114-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 45mm - 71mm, Catalog number 04.808.007. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable
- Z-0116-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 71mm - 97mm, Catalog number 04.808.009. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable
- Z-0109-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 17mm - 25mm, Catalog number 04.808.002. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstable
- Z-0118-2010 · Sep 14, 2009 · TerminatedSynthes USA, TI Synex (TM) II Central Body 97mm - 123mm, Catalog number 04.808.011. Intended for use in the thoracolumbar spine (T1-L5) to replace a collapsed, damaged, or unstabl
Other SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices
- GIZA Corpectomy implant Giza, Diam 14 mm, 23-32 mm, 7-10 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- X-CORE 7160012Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7220018Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7160014Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7180018Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7180016Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 18-22 mm, 2-5 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 23-32 mm, 2-5 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page