OPAL 08.803.051Recalls & reported problems
Synthes GmbH · OPAL SPACER 10MM X 24MM 11MM HEIGHT-REVOLVE · Class 2 · Implant
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034754338), received between May 3, 2018 and May 3, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
- Migration or Expulsion of Device1
Patient problems
- No Code Available1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 3, 2018Break; Migration or Expulsion of Device; Break; Migration or Expulsion of Device
IT WAS REPORTED THAT THE PATIENT UNDERWENT A TWO LEVEL MINIMALLY INVASIVE TRANSFORMATION LUMBAR INTERBODY FUSION (MIS TLIF) ON (B)(6) 2018 TREATING THE LUMBOSACRAL LEVELS 4/5 (L4/L5) AND 5/1 (L5/L1) WITH AN OPAL SPACER. ONLY THE SPACER AT THE L4/5 LEVEL RETRO PULSED. THE SPACER AT L5/S1 STAYED IN PLACE. AFTER SIX (6) WEEKS OF TAKING A FEW FALLS, THE PATIENT HAD EXPERIENCED BACK PAIN AND SOUGHT OUT MEDICAL ATTENTION. THE SPACERS WERE FIXED WITH A PEDICLE SCREW AND ROD CONSTRUCT AND THOSE WERE NOT AFFECTED BY THE PATIENT FALLS. ADDITIONALLY, IT WAS ALSO REPORTED THAT UPON X-RAY, THE PATIENTS INTER BODY SPACER AT THE L4/L5 HAD RETRO PULSED. IN ORDER TO TREAT THE PATIENT, THE SURGEON INTENDS TO PERFORM A PROCEDURE ANTERIORLY TO REMOVE THE RETRO PULSED SPACER AND RE-INSTRUMENT WITH A LOCKING STAND-ALONE SPACER. AN ANTERIOR PROCEDURE WAS SCHEDULED FOR (B)(6) 2018 TO REMOVE THE SPACER AND RE-INSTRUMENT WITH AN ANTERIOR SPACER. THIS COMPLAINT INVOLVES ONE (1) DEVICE. THIS REPORT IS 1 OF 1 FOR (B)(4).
Patient problems: No Code Available; Pain
MAUDE report 7483619 ↗
Other SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices
- X-CORE 7160014Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7220016Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 23-32 mm, 2-5 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- X-CORE 7180018Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 33-54 mm, 7-10 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- GIZA Corpectomy implant Giza, Diam 14 mm, 18-22 mm, 5-8 DegEden Spine Europe SA · Spinal Vertebral Body Replacement Device1 recall0 reports
- X-CORE 7220018Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
- X-CORE 7180016Nuvasive, Inc. · SPINAL VERTEBRAL BODY REPLACEMENT DEVICE1 recall0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.