OPAL 08.803.107Recalls & reported problems
Synthes GmbH · OPAL SPACER 10MM X 28MM 7MM HEIGHT · Class 2 · Implant
All models of OPAL (10)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10705034754376), received between Oct 24, 2023 and Oct 24, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Compatibility Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Compatibility Problem2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 24, 2023Compatibility Problem; Compatibility Problem
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, A PLIF (L5/S1) WAS PERFORMED. THE SURGEON ATTEMPTED TO REMOVE THE CAGE INSERTED INTO THE RIGHT SIDE BECAUSE IT HAD BEEN INSERTED TOO FAR ANTERIOR. THE CAGE WAS DAMAGED DURING REMOVAL BECAUSE THERE WAS NO DEDICATED DEVICE TO REMOVE IT, THE SURGEON HAD DIFFICULTY REMOVING THE CAGE. ONLY 2 CAGES OF THE SAME SIZE HAD BEEN PREPARED, THE CAGE WITH THE SAME SIZE WAS UNABLE TO BE INSERTED AFTER THE CAGE IN QUESTION WAS DAMAGED. SUBSEQUENTLY, THE SURGEON INSERTED A CAGE SIZED LARGER (9 MM HEIGHT), AND IT WAS SUCCESSFULLY INSERTED. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH NO SURGICAL DELAY. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR AN OPAL SPACER 10MM X 28MM 7MM HEIGHT. THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17995992 ↗MalfunctionOct 24, 2023Compatibility Problem; Compatibility Problem
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, A PLIF (L5/S1) WAS PERFORMED. THE SURGEON ATTEMPTED TO REMOVE THE CAGE INSERTED INTO THE RIGHT SIDE BECAUSE IT HAD BEEN INSERTED TOO FAR ANTERIOR. THE CAGE WAS DAMAGED DURING REMOVAL BECAUSE THERE WAS NO DEDICATED DEVICE TO REMOVE IT, THE SURGEON HAD DIFFICULTY REMOVING THE CAGE. ONLY 2 CAGES OF THE SAME SIZE HAD BEEN PREPARED, THE CAGE WITH THE SAME SIZE WAS UNABLE TO BE INSERTED AFTER THE CAGE IN QUESTION WAS DAMAGED. SUBSEQUENTLY, THE SURGEON INSERTED A CAGE SIZED LARGER (9 MM HEIGHT), AND IT WAS SUCCESSFULLY INSERTED. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH NO SURGICAL DELAY. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR AN OPAL SPACER 10MM X 28MM 7MM HEIGHT. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17995989 ↗
Other Intervertebral fusion device with bone graft, lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page