Skip to content

OPAL 08.803.131Recalls & reported problems

Synthes GmbH · OPAL SPACER 10MM X 28MM 11MM HEIGHT-REVOLVE · Class 2 · Implant

All models of OPAL (10)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034754499), received between Jan 10, 2018 and Jan 10, 2018 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 10, 2018Break; Break

    IT WAS REPORTED THAT DURING A TRANSFORAMINAL LUMBAR INTERBODY FUSION (TLIF) OPERATION ON (B)(6) 2017, A OPAL SPACER 10MM X 28MM 11MM HEIGHT-REVOLVE BROKE WHEN THE SURGEON WAS TRYING TO IMPLANT IT IN THE DISC SPACE. THE FRAGMENTS GENERATED DUE TO BROKEN DEVICE WERE EASILY REMOVED WITHOUT ANY ADDITIONAL INTERVENTION. THERE WAS 10-15 MINUTES OF SURGICAL DELAY. THE SURGERY WAS COMPLETED WITH ANOTHER AVAILABLE DEVICE. THE PATIENT WAS STABLE AFTER THE SURGERY. CONCOMITANT DEVICES REPORTED: UNKNOWN PLATE (PART # UNKNOWN, LOT # UNKNOWN, QUANTITY 1). THIS REPORT IS FOR ONE (1) OPAL SPACER 10MM X 28MM 11MM HEIGHT-REVOLVE. (B)(4).

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7179068 ↗

FDA clearance and classification

The FDA regulates product code MQP (spinal vertebral body replacement device) under 21 CFR 888.3060 as a Class II device. 21 CFR 888.3060 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the OPAL 08.803.131

Has the OPAL 08.803.131 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10705034754499), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the OPAL 08.803.131?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Jan 10, 2018. That report lists device problem “Break” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the OPAL 08.803.131?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the OPAL 08.803.131 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the OPAL 08.803.131, and is it still sold?

The FDA's device database lists Synthes GmbH as the company responsible for it (brand OPAL, model 08.803.131). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices

All SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page