VITROS 6844294Recalls & reported problems

Ortho-Clinical Diagnostics, Inc. · VITROS XT Chemistry Products UREA-CREA Slides · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10758750031788), received between Aug 14, 2025 and Mar 5, 2026 — classified as 5 malfunctions.

The most frequently reported specific device problem is “High Test Results” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 2 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • High Test Results4
  • Low Test Results1
  • Non Reproducible Results1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 5, 2026High Test Results

    A CUSTOMER CONTACTED THE ORTHO CLINICAL DIAGNOSTICS (ORTHO) TECHNICAL SOLUTION CENTER (TSC) TO REPORT HIGHER THAN EXPECTED VITROS CREATININE XT (CREAXT) RESULTS WERE OBTAINED FROM TWO DIFFERENT SAMPLES COLLECTED FROM THE SAME PATIENT TESTED ON TWO DIFFERENT VITROS XT7600 INTEGRATED SYSTEMS. THE RESULTS WERE CONSIDERED HIGHER THAN EXPECTED WHEN COMPARED TO A NON-VITROS CREATINE RESULT OBTAINED FROM ONE OF THE SAMPLES AND VITROS CREAXT RESULTS OBTAINED FROM SAMPLES COLLECTED FROM THE SAME PATIENT WITHIN THE TIMEFRAME. (B)(6) PATIENT SAMPLE 1 VITROS CREAXT RESULT OF 2.7 MG/DL VS. THE SAMPLE 2 VITROS CREAXT RESULT OF 0.9 MG/DL (B)(6) PATIENT SAMPLE 3 VITROS CREAXT RESULT OF 2.1 MG/DL VS. THE SAMPLE 3 NON-VITROS CREATININE RESULT OF 1.1 MG/DL BIASED RESULTS OF THE MAGNITUDE AND DIRECTION OBSERVED MAY LEAD TO INAPPROPRIATE PHYSICIAN ACTION IF THEY WERE TO OCCUR UNDETECTED. THE HIGHER-THAN-EXPECTED VITROS CREAXT RESULTS WERE NOT REPORTED FROM THE LABORATORY AND THERE WAS NO ALLEGATION OF PATIENT HARM AS A RESULT OF THE EVENT. THIS REPORT IS NUMBER ONE OF TWO MDRS FOR THIS EVENT. TWO 3500A FORMS ARE BEING SUBMITTED FOR THIS EVENT AS TWO DEVICES WERE INVOLVED. THIS REPORT CORRESPONDS TO ORT

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24523905 ↗
  • MalfunctionMar 5, 2026High Test Results

    A CUSTOMER CONTACTED THE ORTHO CLINICAL DIAGNOSTICS (ORTHO) TECHNICAL SOLUTION CENTER (TSC) TO REPORT HIGHER THAN EXPECTED VITROS CREATININE XT (CREAXT) RESULTS WERE OBTAINED FROM TWO DIFFERENT SAMPLES COLLECTED FROM THE SAME PATIENT TESTED ON TWO DIFFERENT VITROS XT7600 INTEGRATED SYSTEMS. THE RESULTS WERE CONSIDERED HIGHER THAN EXPECTED WHEN COMPARED TO A NON-VITROS CREATINE RESULT OBTAINED FROM ONE OF THE SAMPLES AND VITROS CREAXT RESULTS OBTAINED FROM SAMPLES COLLECTED FROM THE SAME PATIENT WITHIN THE TIMEFRAME. (B)(6) PATIENT SAMPLE 1 VITROS CREAXT RESULT OF 2.7 MG/DL VS. THE SAMPLE 2 VITROS CREAXT RESULT OF 0.9 MG/DL (B)(6) PATIENT SAMPLE 3 VITROS CREAXT RESULT OF 2.1 MG/DL VS. THE SAMPLE 3 NON-VITROS CREATININE RESULT OF 1.1 MG/DL BIASED RESULTS OF THE MAGNITUDE AND DIRECTION OBSERVED MAY LEAD TO INAPPROPRIATE PHYSICIAN ACTION IF THEY WERE TO OCCUR UNDETECTED. THE HIGHER-THAN-EXPECTED VITROS CREAXT RESULTS WERE NOT REPORTED FROM THE LABORATORY AND THERE WAS NO ALLEGATION OF PATIENT HARM AS A RESULT OF THE EVENT. THIS REPORT IS NUMBER TWO OF TWO MDRS FOR THIS EVENT. TWO 3500A FORMS ARE BEING SUBMITTED FOR THIS EVENT AS TWO DEVICES WERE INVOLVED. THIS REPORT CORRESPONDS TO ORT

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24523897 ↗
  • MalfunctionNov 21, 2025High Test Results; High Test Results

    A CUSTOMER CONTACTED THE ORTHO CLINICAL DIAGNOSTICS (ORTHO) TECHNICAL SOLUTION CENTER (TSC) TO REPORT A DISCORDANT, HIGHER THAN EXPECTED VITROS CREATININE (CREA) RESULT WAS OBTAINED FROM A SINGLE PATIENT SAMPLE PROCESSED USING VITROS XT CHEMISTRY PRODUCTS UREA-CREA SLIDES LOT: 7221-0020-2434 ON A VITROS XT 7600 INTEGRATED SYSTEM. THE RESULT WAS DISCORDANT WHEN COMPARED TO THE RESULT FROM THE SAME SAMPLE USING A NON-VITROS SIEMENS ATELLICA METHOD. PATIENT SAMPLE VITROS CREA RESULT OF 2.21 MG/DL VS AN EXPECTED RESULT OF 1.42 MG/DL BIASED RESULTS OF THE MAGNITUDE AND DIRECTION OBSERVED MAY LEAD TO INAPPROPRIATE PHYSICIAN ACTION IF THEY WERE TO OCCUR UNDETECTED. THE DISCORDANT, HIGHER THAN EXPECTED VITROS CREA RESULT WAS NOT REPORTED OUTSIDE OF THE LABORATORY. THERE WAS NO ALLEGATION OF PATIENT HARM AS A RESULT OF THIS EVENT. THIS REPORT CORRESPONDS TO ORTHO CLINICAL DIAGNOSTICS INC (ORTHO) COMPLAINT NUMBER (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23621867 ↗
  • MalfunctionOct 16, 2025High Test Results; High Test Results

    A CUSTOMER CONTACTED THE ORTHO CLINICAL DIAGNOSTICS (ORTHO) TECHNICAL SOLUTION CENTER (TSC) TO REPORT HIGHER THAN EXPECTED VITROS CREATININE XT (CREAXT) RESULTS WERE OBTAINED FROM A SINGLE PATIENT SAMPLE. THE RESULTS WERE CONSIDERED HIGHER THAN EXPECTED WHEN COMPARED TO THE VITROS CREAXT RESULT OBTAINED FROM A SECOND SAMPLE COLLECTED FROM THE SAME PATIENT. VITROS CREA PATIENT SAMPLE 1 RESULTS OF 2.17 AND 1.85 MG/DL VS SAMPLE 2 VITROS CREAXT RESULT OF 0.91 MG/DL BIASED RESULTS OF THE MAGNITUDE AND DIRECTION OBSERVED MAY LEAD TO INAPPROPRIATE PHYSICIAN ACTION IF THEY WERE TO OCCUR UNDETECTED. THE HIGHER-THAN-EXPECTED VITROS CREAXT RESULT OF 2.17 MG/DL WAS REPORTED FROM THE LABORATORY, HOWEVER, NO TREATMENT WAS STOPPED, STARTED OR ALTERED. THE HIGHER-THAN-EXPECTED VITROS CREAXT RESULT OF 1.85 MG/DL WAS NOT REPORTED FROM THE LABORATORY. THERE WAS NO ALLEGATION OF PATIENT HARM AS A RESULT OF THE EVENT. THIS REPORT CORRESPONDS TO ORTHO CLINICAL DIAGNOSTICS INC (ORTHO) COMPLAINT NUMBER (B)(4) AND REPORTABILITY ASSESSMENT (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23310069 ↗
  • MalfunctionAug 14, 2025Low Test Results; Non Reproducible Results; Low Test Results; Non Reproducible Results

    A CUSTOMER CONTACTED THE ORTHO CLINICAL DIAGNOSTICS (ORTHO) TECHNICAL SOLUTION CENTER (TSC) TO REPORT A NON-REPRODUCIBLE, LOWER THAN EXPECTED VITROS CREATININE (CREA) RESULT WAS OBTAINED FROM A SINGLE PATIENT SAMPLE PROCESSED USING VITROS XT CHEMISTRY PRODUCTS UREA-CREA SLIDES LOT 7222-0021-3935 ON A VITROS XT 7600 INTEGRATED SYSTEM. PATIENT SAMPLE VITROS CREA RESULT OF <0.25 MG/DL VS AN EXPECTED RESULT OF 4.96 MG/DL BIASED RESULTS OF THE MAGNITUDE AND DIRECTION OBSERVED MAY LEAD TO INAPPROPRIATE PHYSICIAN ACTION IF THEY WERE TO OCCUR UNDETECTED. THE NON-REPRODUCIBLE, LOWER THAN EXPECTED VITROS CREA RESULT WAS REPORTED OUTSIDE OF THE LABORATORY. HOWEVER, A PHYSICIAN QUESTIONED THE RESULT, AND NO TREATMENT WAS INITIATED, ALTERED OR STOPPED BASED ON THE RESULT. A CORRECTED REPORT WAS LATER ISSUED FOR THE PATIENT. THERE WAS NO ALLEGATION OF PATIENT HARM AS A RESULT OF THIS EVENT. THIS REPORT CORRESPONDS TO ORTHO CLINICAL DIAGNOSTICS INC (ORTHO) COMPLAINT NUMBER (B)(4) AND REPORTABILITY ASSESSMENT 611632.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22806684 ↗

Other UREASE, PHOTOMETRIC, UREA NITROGEN devices

All UREASE, PHOTOMETRIC, UREA NITROGEN devices →