VITROS 6900053Recalls & reported problems

Ortho Clinical Diagnostics · VITROS Immunodiagnostic Products Intact PTH II Calibrators · Class 2

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10758750032716), received between Jun 9, 2026 and Aug 3, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “High Test Results” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • High Test Results2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 3, 2026High Test Results

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50117269 ↗
  • MalfunctionJun 9, 2026High Test Results

    A CUSTOMER CONTACTED THE ORTHO CLINICAL DIAGNOSTICS (ORTHO) TECHNICAL SOLUTION CENTER (TSC) TO REPORT HIGHER THAN EXPECTED VITROS IPTH2 RESULTS OBTAINED FROM TWO LEVELS OF NON-VITROS BIORAD LOT 88750 QUALITY CONTROLS AND TWO DIFFERENT PATIENT CORRELATION SAMPLES USING VITROS IMMUNODIAGNOSTICS PRODUCTS IPTH2 CALIBRATORS, LOT 0330 TESTED ON A VITROS 5600 INTEGRATED SYSTEM. BIORAD L1 VITROS IPTH2 RESULTS OF 41.5, 40.4, 39.8 AND 41.1 NG/ML VS. THE EXPECTED VITROS IPTH2 BASELINE MEAN RESULT OF 30.29 NG/ML. BIORAD L2 VITROS IPTH2 RESULTS OF 636.4, 633.9, 643.3 AND 648.7 NG/ML VS. THE EXPECTED VITROS IPTH2 BASELINE MEAN RESULT OF 461.89 NG/ML PATIENT CORRELATION SAMPLE 1 VITROS IPTH2 RESULT OF 100.7 NG/ML VS. THE EXPECTED VITROS IPTH2 RESULT OF 74.2 NG/ML. PATIENT CORRELATION SAMPLE 2 VITROS IPTH2 RESULT OF 153.5 NG/ML VS. THE EXPECTED VITROS IPTH2 RESULT OF 113.5 NG/ML. BIASED RESULTS OF THE MAGNITUDE AND DIRECTION OBSERVED MAY LEAD TO INAPPROPRIATE PHYSICIAN ACTION IF THEY WERE TO OCCUR UNDETECTED ON PATIENT SAMPLES. THE HIGHER THAN EXPECTED RESULTS WERE OBTAINED FROM CORRELATION SAMPLES THAT WERE NOT REPORTED OUTSIDE OF THE LABORATORY OR FROM NON-PATIENT QUALITY CONTROL SAMPLES. THERE

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25443134 ↗

Other Calibrator, secondary devices