Skip to content

ARROW IPN036440 (REF CDC-42703-XP1A)Recalls & reported problems

Teleflex Incorporated · Pressure Injectable Multi-Lumen Central Venous Catheterization Kit with Blue FlexTip(R), ARROWg+ard Blue PLUS(R) Catheter, Sharps Safety Features, and Maximal Barrier Preca · Class 2 · Implant

All models of ARROW (1494)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10801902117080), received between Sep 25, 2023 and Nov 12, 2025 — classified as 1 injury, 5 malfunctions.

The most frequently reported specific device problem is “Material Separation” (3 reports).

54 other recalls cover devices cleared under the same FDA submission (K071538); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 2 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Separation3
  • Material Twisted/Bent2
  • Connection Problem1
  • Unraveled Material1

Patient problems

  • Hemorrhage/Blood Loss/Bleeding2
  • No Clinical Signs, Symptoms or Conditions2
  • Foreign Body In Patient1
  • Insufficient Information1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 12, 2025Material Separation; Material Separation

    IT WAS REPORTED "THE CATHETER BROKE OFF FROM THE BASE/TIP WITH NO RESISTANCE AND COULD NOT BE RETRIEVED UNDER THE PATIENT'S SKIN." THE CATHETER WAS REMOVED BY IR RETRIEVAL. THERE WAS NO SIGNS OR SYMPTOMS AFTER THE EVENT. THE PATIENT'S CURRENT CONDITION IS REPORTED AS "STABLE AND DISCHARGED HOME".

    Patient problems: Foreign Body In Patient

    MAUDE report 23532416 ↗
  • MalfunctionApr 24, 2024Connection Problem; Connection Problem

    IT WAS REPORTED "THE INTRODUCER NEEDLE SLIDES OFF THE SYRINGE IF GEL OR BLOOD GETS ON IT. THE INTRODUCER NEEDLE DOES NOT STAY STATIONARY WHEN PLACE ON THE SYRINGE". ADDITIONAL INFORMATION WAS REQUESTED FROM THE CUSTOMER, NO ADDITIONAL INFORMATION AVAILABLE AT THIS TIME.

    Patient problems: Insufficient Information

    MAUDE report 19172911 ↗
  • MalfunctionMar 13, 2024Unraveled Material; Material Twisted/Bent; Unraveled Material; Material Twisted/Bent

    IT WAS REPORTED "SPRING WIRE GUIDE KINKS EASILY". NO MEDICAL INTERVENTION REQUIRED. THE PATIENT'S CURRENT CONDITION IS REPORTED AS "FINE". ASSOCIATED MDR NUMBERS INCLUDE: 9680794-2024-00226, 9680794-2024-00227, AND 9680794-2024-00225.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18893813 ↗
  • MalfunctionMar 13, 2024Material Twisted/Bent; Material Twisted/Bent

    IT WAS REPORTED "SPRING WIRE GUIDE KINKS EASILY". NO MEDICAL INTERVENTION REQUIRED. THE PATIENT'S CURRENT CONDITION IS REPORTED AS "FINE". ASSOCIATED MDR NUMBERS INCLUDE: 9680794-2024-00226, 9680794-2024-00310, 9680794-2024-00227.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18893723 ↗
  • MalfunctionSep 25, 2023Material Separation; Material Separation

    MEDWATCH REPORT RECEIVED: "ON (B)(6) 2023 THIS PATIENT HAD A 20CM LEFT SUBCLAVIAN CVC PLACED BY IR. IT FUNCTIONED PROPERLY, UNTIL (B)(6) 2023 WHEN RN HEARD A LITTLE POP AND SAW THAT THE DISTAL LUMEN HAD COME OFF AT THE PLASTIC BROWN PART AND BLOOD WAS LEAKING OUT. RN CLAMPED LINE AND TIED A KNOT IN THE LUMEN. MD CONTACTED AND CENTRAL LINE WAS REMOVED. REF REPORT: MW5120619." NO PATIENT HARM WAS REPORTED. THE CVC WAS REMOVED AND A NEW ONE PLACED. THE PATIENT'S CONDITION IS REPORTED AS "STABLE".

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 17810220 ↗
  • MalfunctionSep 25, 2023Material Separation; Material Separation

    MEDWATCH REPORT RECEIVED: "ON (B)(6) 2023 THIS PATIENT HAD A 20CM LEFT SUBCLAVIAN CVC PLACED BY IR. IT FUNCTIONED PROPERLY, UNTIL (B)(6) 2023 WHEN RN HEARD A LITTLE POP AND SAW THAT THE DISTAL LUMEN HAD COME OFF AT THE PLASTIC BROWN PART AND BLOOD WAS LEAKING OUT. RN CLAMPED LINE AND TIED A KNOT IN THE LUMEN. MD CONTACTED AND CENTRAL LINE WAS REMOVED. REF REPORT: MW5120620." NO PATIENT HARM WAS REPORTED. THE CVC WAS REMOVED AND A NEW ONE PLACED. THE PATIENT'S CONDITION IS REPORTED AS "STABLE".

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 17809843 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K071538. One submission often covers many models, so check the product and lot details in each record.

  • Z-2376-2026 · Apr 21, 2026 · Open, Classified
    Description/REF: CVC/PSI KIT: 2 LUMEN 8 FR X 6 IN/ASK-42802-PLH; CVC KIT: 3-LUMEN 12 FR X 16 CM/AK-12123-F; CVC KIT: 3-LUMEN 12 FR X 20 CM/AK-15123-F; 3L CVC KIT: 7 FR X 16 CM/ASK-
  • Z-1914-2026 · Mar 11, 2026 · Open, Classified
    ARROW, ARROWG+ARD AND ARROWG+ARD BLUE PLUS PRESSURE INJECTABLE CENTRAL VENOUS CATHETER REF ASK-42802-PLH UDI code: (01)10801902133110(17)261231(11)251211(10)33F25L0140 REF ASK-4
  • Z-2123-2026 · Jan 7, 2026 · Open, Classified
    Medline Convenience Kits: 1) KIT TRIPLE LUMEN INSERTION, Model Number: DYNDM1031A
  • Z-0003-2024 · Aug 10, 2023 · Open, Classified
    Arrow Pressure Injectable Arrowg+ard Blue Plus Four-Lumen CVC, REF CDC-45854-P1A; catheter, intravascular, therapeutic, long-term greater than 30 days
  • Z-0002-2024 · Aug 10, 2023 · Open, Classified
    Arrow ErgoPack Complete, Pressure Injectable Arrowg+ard Blue Plus Four-Lumen CVC, REF CDC-42854- PCN1A; catheter, intravascular, therapeutic, long-term greater than 30 days
  • Z-0351-2023 · Oct 27, 2022 · Terminated
    Arrow MAC Two-Lumen Central Venous Access Kit fr use with 7 - 7.5 Fr Catheters, REF ASK-11242-UPM1; catheter introducer
  • Z-0352-2023 · Oct 27, 2022 · Terminated
    Pressure Injectable Arrowg+ard Blue Plus Three-Lumen CVC Kit, REF numbers: a) ASK-42703-NS, b) ASK-42703-PCCH2, c) ASK-42703-PUPM1, d) ASK-45703-NS, e) ASK-45703-PAU, f) ASK-45703-
  • Z-1604-2022 · May 25, 2022 · Open, Classified
    TELEFLEX LLC Arrow Central Venous Catheter Kit 16, 18 Gauge Multi Lumen Model Number:CDC-45703-XP1A (Model Numbers # IPN035619, IPN036437, IPN922677)
  • Z-1995-2018 · Apr 11, 2018 · Terminated
    Pressure Injectable Multi-Lumen Central Venous Catheterization Kit with Blue FlexTip, ARROWg+ard Blue PLUS Catheter, Sharps Safety Features and Maximal Barrier Precautions; Product
  • Z-1990-2018 · Apr 11, 2018 · Terminated
    Pressure Injectable Two-Lumen Central Venous Catheterization Kit with Blue FlexTip(R), ARROWg+ard Blue PLUS(R) Catheter and Sharps Safety Features; Product Code: ASK-45802-PHMW
  • Z-2000-2018 · Apr 11, 2018 · Terminated
    ARROWg+ard Blue PLUS(R) Multi-Lumen Central Venous Catheterization Kit; Product Code: ASK-42703-SJH
  • Z-1996-2018 · Apr 11, 2018 · Terminated
    Pressure Injectable Multi-Lumen Central Venous Catheterization Kit with Blue FlexTip(R), ARROWg+ard Blue PLUS(R) Catheter, Sharps Safety Features and Maximal Barrier Precautions; P
  • Z-1988-2018 · Apr 11, 2018 · Terminated
    Pressure Injectable ARROWg+ard Blue PLUS(R) Multi-Lumen Central Venous Catheterization Kit; Product Codes: ASK-42703-PAM1, ASK-42703-PSHR1, ASK-45703-PNY, ASK-45703-PWHC1
  • Z-1994-2018 · Apr 11, 2018 · Terminated
    ARROWg+ard Blue PLUS Pressure Injectable Multi-Lumen CVC Kit; Product Codes: CDC-45703-P1A; CDC-45703-PB1A; CDC-42703-P1A; and CDC-15703-P1A
  • Z-1980-2018 · Apr 11, 2018 · Terminated
    Pressure Injectable Multi-Lumen Central Venous Catheterization Kit; Product Code: ASK-15703-PHMC

…and 39 more.

Other Catheter,intravascular,therapeutic,short-term less than 30 days devices

All Catheter,intravascular,therapeutic,short-term less than 30 days devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page