Medical Action Industries 58193Recalls & reported problems
Medical Action Industries Inc. · Kit: Central Line Dres 20/Cs · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10809160008195), received between Mar 9, 2021 and Mar 9, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Component Misassembled” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Component Misassembled1
- Material Split, Cut or Torn1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 9, 2021Component Misassembled; Material Split, Cut or Torn
WHILE COMPLETING A DRESSING CHANGE ON A PATIENT A DEFECT WITH THE TEGADERM W//CHG WAS DISCOVERED ON THE KIT WITH LOT #279271. THE RN NOTICED SEVERAL CUTS AROUND THE EDGES OF DRESSING AND AFTER PEELING THE BACK PAPER TO APPLY TO PATIENT, THE STICKY SIDE WAS FACED UPWARD. WE LOOK AT ALL DRESSING IN BOTH SUPPLY ROOMS THIS WAS THE ONLY KIT WITH LOT # 279271. MOST ALL OTHERS WERE LOT #275593 AND THESE DRESSINGS APPEAR TO BE FINE.
Patient problems: Insufficient Information
MAUDE report 11445299 ↗
Other Central venous catheter dressing change kit devices
- Medical Action Industries 59816BMedical Action Industries Inc. · Central venous catheter dressing change kit1 recall0 reports
- Medical Action Industries 79544BMedical Action Industries Inc. · Central venous catheter dressing change kit1 recall0 reports
- MEDICAL ACTION INDUSTRIES 79420Medical Action Industries Inc. · Central venous catheter dressing change kit1 recall0 reports
- Medical Action Industries 74564Medical Action Industries Inc. · Central venous catheter dressing change kit3 reports
- MEDICAL ACTION INDUSTRIES 77433Medical Action Industries Inc. · Central venous catheter dressing change kit2 reports
- medical action industries 77993DMedical Action Industries Inc. · Central venous catheter dressing change kit1 report
- Medical Action Industries 75911DMedical Action Industries Inc. · Central venous catheter dressing change kit1 report
- McKesson 25-2835Mckesson Medical-Surgical Inc. · Central Venous Catheter Dressing Change Kit1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page