Paired VNS 3000 (UDI 10810041430066)Recalls & reported problems
Microtransponder · Lead, 2 mm cuff · Class 3 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10810041430066), received between Jul 24, 2023 and May 15, 2026 — classified as 3 injuries.
The most frequently reported specific device problem is “Patient-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Patient-Device Incompatibility1
- Use of Device Problem1
Patient problems
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Cough1
- No Clinical Signs, Symptoms or Conditions1
- Paresis1
- Unspecified Musculoskeletal problem1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMay 15, 2026Patient-Device Incompatibility; Adverse Event Without Identified Device or Use Problem
DURING THE INITIAL IMPLANTATION PROCEDURE FOR THE VIVISTIM SYSTEM, THE SURGEON IDENTIFIED ANATOMICAL LIMITATIONS INVOLVING THE PATIENT'S VAGUS NERVE THAT PREVENTED SAFE PLACEMENT OF THE HELICAL LEAD. THE VAGUS NERVE WAS REPORTED TO BE TOO SMALL FOR THE 2 MM HELICAL LEAD AND CONTAINED MULTIPLE BRANCHES THAT INTERFERED WITH LEAD PLACEMENT. THE IMPLANTING PHYSICIAN CONSULTED A COLLEAGUE INTRAOPERATIVELY TO CONFIRM IDENTIFICATION OF THE VAGUS NERVE, AND THE COLLEAGUE CONCURRED WITH THE ASSESSMENT. DUE TO THE PATIENT'S ANATOMY, THE IMPLANT PROCEDURE WAS ABORTED AND THE DEVICE WAS NOT IMPLANTED. NO DEVICE MALFUNCTION WAS IDENTIFIED. NO INJURY TO THE PATIENT WAS REPORTED AND THE PATIENT RECOVERED FROM THE PROCEDURE WITHOUT THE NEED FOR ADDITIONAL MEDICAL OR SURGICAL INTERVENTION RELATED TO THE EVENT. THE EVENT IS CONSIDERED RELATED TO PATIENT ANATOMY RATHER THAN DEVICE PERFORMANCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25186469 ↗InjuryFeb 6, 2026Use of Device Problem
THE PATIENT UNDERWENT A SURGICAL POCKET REVISION PROCEDURE BECAUSE THE LEAD CONNECTOR BOOT WAS POSITIONED IN A MANNER THAT ITS SHAPE COULD BE SEEN BELOW THE SKIN. THE PATIENT HAD A COSMETIC CONCERN AND THE PHYSICIAN ALSO FELT THAT THERE MAY BE A RISK OF EROSION AT THAT AREA. THE POCKET REVISION WAS COMPLETED AND THE FINAL POSITION OF THE LEAD CONNECTOR BOOT WAS DEEPER AND MUCH LESS SUPERFICIAL THAN BEFOREHAND. THERE WERE NO COMPLICATIONS DURING THE PROCEDURE.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Unspecified Musculoskeletal problem
MAUDE report 24284761 ↗InjuryJul 24, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PATIENT REPORTED COUGHING, HOARSENESS AND DIFFICULTY HAVING CONVERSATIONS POST IMPLANT. THE PATIENT FOLLOWED UP WITH IMPLANTING PHYSICIAN AND CONSULTED A VOICE DISORDER SPECIALIST. PER THE PATIENT, THEY HAD VOCAL CORD FILLER AND SYMPTOMS HAVE IMPROVED. DEVICE HISTORY RECORDS WERE REVIEWED FOR IPG S/N (B)(6) AND LEAD S/N (B)(6). THE DEVICES PASSED ALL FUNCTIONAL SPECIFICATIONS AND QUALITY TESTS AND WERE STERILIZED PRIOR TO DISTRIBUTION. NO OTHER RELEVANT INFORMATION HAS BEEN RECEIVED TO DATE.
Patient problems: Cough; Paresis
MAUDE report 17380118 ↗
Other Stimulator, Autonomic Nerve, Implanted For Stroke Rehabilitation devices
- Vivistim® 1001Microtransponder · Stimulator, Autonomic Nerve, Implanted For Stroke Rehabilitation37 reports
- Paired VNS 3000Microtransponder · Stimulator, Autonomic Nerve, Implanted For Stroke Rehabilitation1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page